MR-ONLY as a reference image in verifying positioning in Radiotherapy
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://doi.org/10.46885/roentgen.v3i2.87 |
Resumo: | Introduction: The planning systems use the information of the electronic densities, needed for the calculation of the dose from the CT. A recent trend is the use of MR as the only modality, using the MR image to create a synthetic CT. A workflow in which all pre-treatment steps are performed at the MR is favorable. The objective of this study is to validate the MR-Only technique as the reference image in the verification of positioning in Radiotherapy. Methods: 13 patients with brain tumor and 15 patients with rectal tumor followed at the Radiotherapy unit of the Champalimaud Clinical Center, from October 2019 to June 2020, were included. Based on the automatic registration of 80 CBCT, the deviations between images of planning CT and synthetic CT (MR-Only) were compared. Results: In the registration of the images in the rectum, the variation that was obtained was less than 1,4mm longitudinal, 1mm laterally and vertically. The variation verified in the translations was -0,2±0,3mm lateral, -0,3±0,4mm vertical and -0,4±0,7mm longitudinal. Regarding rotations were lower than 0,4º, with the variation verified 0,0±0,2º pitch, 0,0±0,1º yaw and 0,0±0,1º roll. In the brain it was less than 1,3mm longitudinally, 0,6mm vertically and 0,4mm laterally. The variation found was -0,2±0,2mm lateral, -0,3±0,2mm vertical and -0,4±0,5mm longitudinal. In the rotations, a maximum rotation of 0,3º was obtained, being the variation verified -0,2±0,1º pitch, 0,1±0,1º yaw and of 0,0±0,1º roll. Conclusion: The registration of the synthetic CT image with the CBCT verification image was validated. The minimum deviations found in the results between the planning CT and the synthetic CT of the MRI suggest that the use of the MR-Only technique as a reference image is justified. |
id |
RCAP_50ce5d00752ab2bd1ec7a7221351a006 |
---|---|
oai_identifier_str |
oai:roentgen.pt:article/87 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
MR-ONLY as a reference image in verifying positioning in RadiotherapyMR-ONLY como imagem de referência na verificação do posicionamento em RadioterapiaRadiotherapyRegistrationMR-OnlySynthetic CTRadioterapiaRegistoMR-OnlyTC sintéticaIntroduction: The planning systems use the information of the electronic densities, needed for the calculation of the dose from the CT. A recent trend is the use of MR as the only modality, using the MR image to create a synthetic CT. A workflow in which all pre-treatment steps are performed at the MR is favorable. The objective of this study is to validate the MR-Only technique as the reference image in the verification of positioning in Radiotherapy. Methods: 13 patients with brain tumor and 15 patients with rectal tumor followed at the Radiotherapy unit of the Champalimaud Clinical Center, from October 2019 to June 2020, were included. Based on the automatic registration of 80 CBCT, the deviations between images of planning CT and synthetic CT (MR-Only) were compared. Results: In the registration of the images in the rectum, the variation that was obtained was less than 1,4mm longitudinal, 1mm laterally and vertically. The variation verified in the translations was -0,2±0,3mm lateral, -0,3±0,4mm vertical and -0,4±0,7mm longitudinal. Regarding rotations were lower than 0,4º, with the variation verified 0,0±0,2º pitch, 0,0±0,1º yaw and 0,0±0,1º roll. In the brain it was less than 1,3mm longitudinally, 0,6mm vertically and 0,4mm laterally. The variation found was -0,2±0,2mm lateral, -0,3±0,2mm vertical and -0,4±0,5mm longitudinal. In the rotations, a maximum rotation of 0,3º was obtained, being the variation verified -0,2±0,1º pitch, 0,1±0,1º yaw and of 0,0±0,1º roll. Conclusion: The registration of the synthetic CT image with the CBCT verification image was validated. The minimum deviations found in the results between the planning CT and the synthetic CT of the MRI suggest that the use of the MR-Only technique as a reference image is justified.Introdução: Os sistemas de planeamento utilizam a informação das densidades eletrónicas, necessárias para o cálculo de dose provenientes da TC. Uma tendência recente é o uso da RM como única modalidade, usando as imagens de RM para criar uma TC sintética. Um fluxo de trabalho no qual todas as etapas pré-tratamento são realizadas na RM é favorável. O objetivo do estudo é validar a técnica MR-Only como imagem de referência na verificação do posicionamento em Radioterapia. Metodologia: Foram incluídos 13 doentes com tumor cerebral e 15 doentes com tumor retal, seguidos no Serviço de Radioterapia do Centro Clínico Champalimaud, de outubro de 2019 a junho de 2020. Com base no registo automático de 80 CBCT comparou-se os desvios entre as imagens da TC de planeamento e da TC sintética (MR-Only). Resultados: No registo das imagens do reto, a variação que se obteve foi inferior a 1,4mm longitudinal, 1mm lateral e vertical. A variação nas translações foi de -0,2±0,3mm lateral, -0,3±0,4mm vertical e de -0,4±0,7mm longitudinal. As rotações foram inferiores a 0,4º, sendo a variação verificada 0,0±0,2º pitch, 0,0±0,1º yaw e de 0,0±0,1º roll. No cérebro foi inferior a 1,3mm longitudinal, a 0,6mm vertical e a 0,4mm lateral. A variação verificada foi de -0,2±0,2mm lateral, -0,3±0,2mm vertical e de -0,4±0,5mm longitudinal. Nas rotações, obteve-se uma rotação máxima de 0,3º, sendo a variação verificada -0,2±0,1º pitch, 0,1±0,1º yaw e de 0,0±0,1º roll. Conclusão: Foi validado o registo da imagem da TC sintética com a imagem de verificação CBCT. Os desvios encontrados nos registos entre a TC de planeamento e a TC sintética da RM sugerem que é justificado o uso da técnica MR-Only como imagem de referência.NUCLIRAD - Núcleo de Desenvolvimento dos Técnicos de Radiologia2022-07-20info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://doi.org/10.46885/roentgen.v3i2.87https://doi.org/10.46885/roentgen.v3i2.87ROENTGEN-Scientific Journal of Radiological Techniques; Vol. 3 No. 2 (2022): Radiological Protection; 64-77ROENTGEN-Revista Científica das Técnicas Radiológicas; v. 3 n. 2 (2022): Proteção Radiológica; 64-772184-7657reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPporhttps://roentgen.pt/index.php/Principal/article/view/87https://roentgen.pt/index.php/Principal/article/view/87/70Direitos de Autor (c) 2022 ROENTGEN-Revista Científica das Técnicas Radiológicasinfo:eu-repo/semantics/openAccessMarques, JoãoCaetano, MarcoStroom, JoepGreco, Carlo2023-12-20T16:17:13Zoai:roentgen.pt:article/87Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:55:20.987929Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
MR-ONLY as a reference image in verifying positioning in Radiotherapy MR-ONLY como imagem de referência na verificação do posicionamento em Radioterapia |
title |
MR-ONLY as a reference image in verifying positioning in Radiotherapy |
spellingShingle |
MR-ONLY as a reference image in verifying positioning in Radiotherapy Marques, João Radiotherapy Registration MR-Only Synthetic CT Radioterapia Registo MR-Only TC sintética |
title_short |
MR-ONLY as a reference image in verifying positioning in Radiotherapy |
title_full |
MR-ONLY as a reference image in verifying positioning in Radiotherapy |
title_fullStr |
MR-ONLY as a reference image in verifying positioning in Radiotherapy |
title_full_unstemmed |
MR-ONLY as a reference image in verifying positioning in Radiotherapy |
title_sort |
MR-ONLY as a reference image in verifying positioning in Radiotherapy |
author |
Marques, João |
author_facet |
Marques, João Caetano, Marco Stroom, Joep Greco, Carlo |
author_role |
author |
author2 |
Caetano, Marco Stroom, Joep Greco, Carlo |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Marques, João Caetano, Marco Stroom, Joep Greco, Carlo |
dc.subject.por.fl_str_mv |
Radiotherapy Registration MR-Only Synthetic CT Radioterapia Registo MR-Only TC sintética |
topic |
Radiotherapy Registration MR-Only Synthetic CT Radioterapia Registo MR-Only TC sintética |
description |
Introduction: The planning systems use the information of the electronic densities, needed for the calculation of the dose from the CT. A recent trend is the use of MR as the only modality, using the MR image to create a synthetic CT. A workflow in which all pre-treatment steps are performed at the MR is favorable. The objective of this study is to validate the MR-Only technique as the reference image in the verification of positioning in Radiotherapy. Methods: 13 patients with brain tumor and 15 patients with rectal tumor followed at the Radiotherapy unit of the Champalimaud Clinical Center, from October 2019 to June 2020, were included. Based on the automatic registration of 80 CBCT, the deviations between images of planning CT and synthetic CT (MR-Only) were compared. Results: In the registration of the images in the rectum, the variation that was obtained was less than 1,4mm longitudinal, 1mm laterally and vertically. The variation verified in the translations was -0,2±0,3mm lateral, -0,3±0,4mm vertical and -0,4±0,7mm longitudinal. Regarding rotations were lower than 0,4º, with the variation verified 0,0±0,2º pitch, 0,0±0,1º yaw and 0,0±0,1º roll. In the brain it was less than 1,3mm longitudinally, 0,6mm vertically and 0,4mm laterally. The variation found was -0,2±0,2mm lateral, -0,3±0,2mm vertical and -0,4±0,5mm longitudinal. In the rotations, a maximum rotation of 0,3º was obtained, being the variation verified -0,2±0,1º pitch, 0,1±0,1º yaw and of 0,0±0,1º roll. Conclusion: The registration of the synthetic CT image with the CBCT verification image was validated. The minimum deviations found in the results between the planning CT and the synthetic CT of the MRI suggest that the use of the MR-Only technique as a reference image is justified. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-07-20 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://doi.org/10.46885/roentgen.v3i2.87 https://doi.org/10.46885/roentgen.v3i2.87 |
url |
https://doi.org/10.46885/roentgen.v3i2.87 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://roentgen.pt/index.php/Principal/article/view/87 https://roentgen.pt/index.php/Principal/article/view/87/70 |
dc.rights.driver.fl_str_mv |
Direitos de Autor (c) 2022 ROENTGEN-Revista Científica das Técnicas Radiológicas info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Direitos de Autor (c) 2022 ROENTGEN-Revista Científica das Técnicas Radiológicas |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
NUCLIRAD - Núcleo de Desenvolvimento dos Técnicos de Radiologia |
publisher.none.fl_str_mv |
NUCLIRAD - Núcleo de Desenvolvimento dos Técnicos de Radiologia |
dc.source.none.fl_str_mv |
ROENTGEN-Scientific Journal of Radiological Techniques; Vol. 3 No. 2 (2022): Radiological Protection; 64-77 ROENTGEN-Revista Científica das Técnicas Radiológicas; v. 3 n. 2 (2022): Proteção Radiológica; 64-77 2184-7657 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799136439991009280 |