Is it necessary to show virtual limbs in action observation neurorehabilitation systems?

Detalhes bibliográficos
Autor(a) principal: Modroño, Cristián
Data de Publicação: 2019
Outros Autores: Bermúdez, Sergi, Cameirão, Mónica, Pereira, Fábio, Paulino, Teresa, Marcano, Francisco, Hernández-Martín, Estefanía, Plata-Bello, Julio, Palenzuela, Nereida, Núñez-Pádron, Daniel, Pérez-González, José M, González-Mora, José L
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.13/3079
Resumo: Action observation neurorehabilitation systems are usually based on the observation of a virtual limb performing different kinds of actions. In this way, the activity in the frontoparietal Mirror Neuron System is enhanced, which can be helpful to rehabilitate stroke patients. However, the presence of limbs in such systems might not be necessary to produce mirror activity, for example, frontoparietal mirror activity can be produced just by the observation of virtual tool movements. The objective of this work was to explore to what point the presence of a virtual limb impacts the Mirror Neuron System activity in neurorehabilitation systems.
id RCAP_50f7cb9de026ff3b773a0980a038e0c9
oai_identifier_str oai:digituma.uma.pt:10400.13/3079
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Is it necessary to show virtual limbs in action observation neurorehabilitation systems?fMRINeurorehabilitationAction observationVirtual realityVirtual limbsMirror neurons.Faculdade de Ciências Exatas e da EngenhariaAction observation neurorehabilitation systems are usually based on the observation of a virtual limb performing different kinds of actions. In this way, the activity in the frontoparietal Mirror Neuron System is enhanced, which can be helpful to rehabilitate stroke patients. However, the presence of limbs in such systems might not be necessary to produce mirror activity, for example, frontoparietal mirror activity can be produced just by the observation of virtual tool movements. The objective of this work was to explore to what point the presence of a virtual limb impacts the Mirror Neuron System activity in neurorehabilitation systems.SageDigitUMaModroño, CristiánBermúdez, SergiCameirão, MónicaPereira, FábioPaulino, TeresaMarcano, FranciscoHernández-Martín, EstefaníaPlata-Bello, JulioPalenzuela, NereidaNúñez-Pádron, DanielPérez-González, José MGonzález-Mora, José L2021-01-19T15:31:48Z2019-01-01T00:00:00Z2019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.13/3079engModroño, C., Bermúdez, S., Cameirão, M., Pereira, F., Paulino, T., Marcano, F., ... & González-Mora, J. L. (2019). Is it necessary to show virtual limbs in action observation neurorehabilitation systems?. Journal of rehabilitation and assistive technologies engineering, 6. https://doi.org/10.1177/205566831985914010.1177/2055668319859140info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-05T12:55:59Zoai:digituma.uma.pt:10400.13/3079Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:05:55.825241Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Is it necessary to show virtual limbs in action observation neurorehabilitation systems?
title Is it necessary to show virtual limbs in action observation neurorehabilitation systems?
spellingShingle Is it necessary to show virtual limbs in action observation neurorehabilitation systems?
Modroño, Cristián
fMRI
Neurorehabilitation
Action observation
Virtual reality
Virtual limbs
Mirror neurons
.
Faculdade de Ciências Exatas e da Engenharia
title_short Is it necessary to show virtual limbs in action observation neurorehabilitation systems?
title_full Is it necessary to show virtual limbs in action observation neurorehabilitation systems?
title_fullStr Is it necessary to show virtual limbs in action observation neurorehabilitation systems?
title_full_unstemmed Is it necessary to show virtual limbs in action observation neurorehabilitation systems?
title_sort Is it necessary to show virtual limbs in action observation neurorehabilitation systems?
author Modroño, Cristián
author_facet Modroño, Cristián
Bermúdez, Sergi
Cameirão, Mónica
Pereira, Fábio
Paulino, Teresa
Marcano, Francisco
Hernández-Martín, Estefanía
Plata-Bello, Julio
Palenzuela, Nereida
Núñez-Pádron, Daniel
Pérez-González, José M
González-Mora, José L
author_role author
author2 Bermúdez, Sergi
Cameirão, Mónica
Pereira, Fábio
Paulino, Teresa
Marcano, Francisco
Hernández-Martín, Estefanía
Plata-Bello, Julio
Palenzuela, Nereida
Núñez-Pádron, Daniel
Pérez-González, José M
González-Mora, José L
author2_role author
author
author
author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv DigitUMa
dc.contributor.author.fl_str_mv Modroño, Cristián
Bermúdez, Sergi
Cameirão, Mónica
Pereira, Fábio
Paulino, Teresa
Marcano, Francisco
Hernández-Martín, Estefanía
Plata-Bello, Julio
Palenzuela, Nereida
Núñez-Pádron, Daniel
Pérez-González, José M
González-Mora, José L
dc.subject.por.fl_str_mv fMRI
Neurorehabilitation
Action observation
Virtual reality
Virtual limbs
Mirror neurons
.
Faculdade de Ciências Exatas e da Engenharia
topic fMRI
Neurorehabilitation
Action observation
Virtual reality
Virtual limbs
Mirror neurons
.
Faculdade de Ciências Exatas e da Engenharia
description Action observation neurorehabilitation systems are usually based on the observation of a virtual limb performing different kinds of actions. In this way, the activity in the frontoparietal Mirror Neuron System is enhanced, which can be helpful to rehabilitate stroke patients. However, the presence of limbs in such systems might not be necessary to produce mirror activity, for example, frontoparietal mirror activity can be produced just by the observation of virtual tool movements. The objective of this work was to explore to what point the presence of a virtual limb impacts the Mirror Neuron System activity in neurorehabilitation systems.
publishDate 2019
dc.date.none.fl_str_mv 2019-01-01T00:00:00Z
2019-01-01T00:00:00Z
2021-01-19T15:31:48Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.13/3079
url http://hdl.handle.net/10400.13/3079
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Modroño, C., Bermúdez, S., Cameirão, M., Pereira, F., Paulino, T., Marcano, F., ... & González-Mora, J. L. (2019). Is it necessary to show virtual limbs in action observation neurorehabilitation systems?. Journal of rehabilitation and assistive technologies engineering, 6. https://doi.org/10.1177/2055668319859140
10.1177/2055668319859140
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sage
publisher.none.fl_str_mv Sage
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799129930486775808