Operation of gas proportional scintillation counters in a low charge multiplication regime
Autor(a) principal: | |
---|---|
Data de Publicação: | 1999 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10316/4555 https://doi.org/10.1016/S0168-9002(98)00966-8 |
Resumo: | The operation of a xenon filled gas proportional scintillation counter under low charge multiplication gains is discussed. It is shown that the best energy resolution for X-rays is obtained for a reduced electric field, E/p, of about 8 V cm-1 Torr-1, leading to a charge gain (for inter-grid distance of 5 mm) of about 1.05, as calculated by a Monte Carlo simulation method. A discussion is presented concerning the dependence of the E/p values for better detector performance, on the inter-grid distance. |
id |
RCAP_5234c4407c0f11a232011f5467b49bd0 |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/4555 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Operation of gas proportional scintillation counters in a low charge multiplication regimeThe operation of a xenon filled gas proportional scintillation counter under low charge multiplication gains is discussed. It is shown that the best energy resolution for X-rays is obtained for a reduced electric field, E/p, of about 8 V cm-1 Torr-1, leading to a charge gain (for inter-grid distance of 5 mm) of about 1.05, as calculated by a Monte Carlo simulation method. A discussion is presented concerning the dependence of the E/p values for better detector performance, on the inter-grid distance.http://www.sciencedirect.com/science/article/B6TJM-3VR1CVW-29/1/cf66fb6eeb6e5fdc4e2c2bf6672578ae1999info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/4555http://hdl.handle.net/10316/4555https://doi.org/10.1016/S0168-9002(98)00966-8engNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 422:1-3 (1999) 321-325Borges, F. I. G. M.Santos, J. M. F. dosDias, T. H. V. T.Santos, F. P.Rachinhas, P. J. B. M.Conde, C. A. N.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-05-25T03:18:27Zoai:estudogeral.uc.pt:10316/4555Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:44.952605Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Operation of gas proportional scintillation counters in a low charge multiplication regime |
title |
Operation of gas proportional scintillation counters in a low charge multiplication regime |
spellingShingle |
Operation of gas proportional scintillation counters in a low charge multiplication regime Borges, F. I. G. M. |
title_short |
Operation of gas proportional scintillation counters in a low charge multiplication regime |
title_full |
Operation of gas proportional scintillation counters in a low charge multiplication regime |
title_fullStr |
Operation of gas proportional scintillation counters in a low charge multiplication regime |
title_full_unstemmed |
Operation of gas proportional scintillation counters in a low charge multiplication regime |
title_sort |
Operation of gas proportional scintillation counters in a low charge multiplication regime |
author |
Borges, F. I. G. M. |
author_facet |
Borges, F. I. G. M. Santos, J. M. F. dos Dias, T. H. V. T. Santos, F. P. Rachinhas, P. J. B. M. Conde, C. A. N. |
author_role |
author |
author2 |
Santos, J. M. F. dos Dias, T. H. V. T. Santos, F. P. Rachinhas, P. J. B. M. Conde, C. A. N. |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Borges, F. I. G. M. Santos, J. M. F. dos Dias, T. H. V. T. Santos, F. P. Rachinhas, P. J. B. M. Conde, C. A. N. |
description |
The operation of a xenon filled gas proportional scintillation counter under low charge multiplication gains is discussed. It is shown that the best energy resolution for X-rays is obtained for a reduced electric field, E/p, of about 8 V cm-1 Torr-1, leading to a charge gain (for inter-grid distance of 5 mm) of about 1.05, as calculated by a Monte Carlo simulation method. A discussion is presented concerning the dependence of the E/p values for better detector performance, on the inter-grid distance. |
publishDate |
1999 |
dc.date.none.fl_str_mv |
1999 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/4555 http://hdl.handle.net/10316/4555 https://doi.org/10.1016/S0168-9002(98)00966-8 |
url |
http://hdl.handle.net/10316/4555 https://doi.org/10.1016/S0168-9002(98)00966-8 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 422:1-3 (1999) 321-325 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
aplication/PDF |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133888362053632 |