Stability of blood gases when refrigerated
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.16/1274 |
Resumo: | Background: Blood gas analysis is a widely used procedure. In clinical practice, the physicians may not always have a blood gas analyzer in their proximity. Not infrequently, blood gas samples are stored in a fridge or on ice and read retrospectively. Continued anaerobic and aerobic metabolism in the blood may alter blood gases in the interval between drawing arterial blood and its analysis, which may cause a fall in the PaO2 and pH and a rise in the PaCO2. Methods: Two sets of arterial blood samples were obtained from hospitalized patients. After the initial analysis, one sample from each patient was put in raw ice within a specimen bag (0 to +1 oC) and the other in the fridge (+4 to +8 oC). These samples were submitted to serial analysis at 30 minutes, 1 hour and 2 hours after the initial analysis. Results: Two hundred arterial blood gas results from 25 patients were analysed. The mean values of PaO2, PaCO2, HCO3-, Na+, K+, Ca2+ and lactate at 0 minutes, 30 minutes, 1 hour and 2 hours were not signifi cantly different between the two alternatives of storage. However, within each group, signifi cant changes were found over time for PaO2, K+, Na+, Ca2+ and lactate. Conclusions: When using plastic syringes, arterial blood gas analysis should be processed shortly after collecting the sample. Despite the fact that low temperatures can slow down the metabolism, neither the ice nor the fridge preserved all the sample parameters. |
id |
RCAP_52d9a328ecbce2341c1c0effb194a7e2 |
---|---|
oai_identifier_str |
oai:repositorio.chporto.pt:10400.16/1274 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Stability of blood gases when refrigeratedblood gas analysisrefrigerationiceplastic syringesBackground: Blood gas analysis is a widely used procedure. In clinical practice, the physicians may not always have a blood gas analyzer in their proximity. Not infrequently, blood gas samples are stored in a fridge or on ice and read retrospectively. Continued anaerobic and aerobic metabolism in the blood may alter blood gases in the interval between drawing arterial blood and its analysis, which may cause a fall in the PaO2 and pH and a rise in the PaCO2. Methods: Two sets of arterial blood samples were obtained from hospitalized patients. After the initial analysis, one sample from each patient was put in raw ice within a specimen bag (0 to +1 oC) and the other in the fridge (+4 to +8 oC). These samples were submitted to serial analysis at 30 minutes, 1 hour and 2 hours after the initial analysis. Results: Two hundred arterial blood gas results from 25 patients were analysed. The mean values of PaO2, PaCO2, HCO3-, Na+, K+, Ca2+ and lactate at 0 minutes, 30 minutes, 1 hour and 2 hours were not signifi cantly different between the two alternatives of storage. However, within each group, signifi cant changes were found over time for PaO2, K+, Na+, Ca2+ and lactate. Conclusions: When using plastic syringes, arterial blood gas analysis should be processed shortly after collecting the sample. Despite the fact that low temperatures can slow down the metabolism, neither the ice nor the fridge preserved all the sample parameters.N Z J Med Lab SciRepositório Científico do Centro Hospitalar Universitário de Santo AntónioFerreira, J.Silva, S.Rodrigues, P.Abreu, M.Maia, J.Carvalho, D.Carvalho, L.2012-08-08T10:00:40Z20122012-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.16/1274engN Z J Med Lab Sci 2012; 66: 42-451171-0195info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-10-20T10:55:20Zoai:repositorio.chporto.pt:10400.16/1274Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:37:42.963571Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Stability of blood gases when refrigerated |
title |
Stability of blood gases when refrigerated |
spellingShingle |
Stability of blood gases when refrigerated Ferreira, J. blood gas analysis refrigeration ice plastic syringes |
title_short |
Stability of blood gases when refrigerated |
title_full |
Stability of blood gases when refrigerated |
title_fullStr |
Stability of blood gases when refrigerated |
title_full_unstemmed |
Stability of blood gases when refrigerated |
title_sort |
Stability of blood gases when refrigerated |
author |
Ferreira, J. |
author_facet |
Ferreira, J. Silva, S. Rodrigues, P. Abreu, M. Maia, J. Carvalho, D. Carvalho, L. |
author_role |
author |
author2 |
Silva, S. Rodrigues, P. Abreu, M. Maia, J. Carvalho, D. Carvalho, L. |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Repositório Científico do Centro Hospitalar Universitário de Santo António |
dc.contributor.author.fl_str_mv |
Ferreira, J. Silva, S. Rodrigues, P. Abreu, M. Maia, J. Carvalho, D. Carvalho, L. |
dc.subject.por.fl_str_mv |
blood gas analysis refrigeration ice plastic syringes |
topic |
blood gas analysis refrigeration ice plastic syringes |
description |
Background: Blood gas analysis is a widely used procedure. In clinical practice, the physicians may not always have a blood gas analyzer in their proximity. Not infrequently, blood gas samples are stored in a fridge or on ice and read retrospectively. Continued anaerobic and aerobic metabolism in the blood may alter blood gases in the interval between drawing arterial blood and its analysis, which may cause a fall in the PaO2 and pH and a rise in the PaCO2. Methods: Two sets of arterial blood samples were obtained from hospitalized patients. After the initial analysis, one sample from each patient was put in raw ice within a specimen bag (0 to +1 oC) and the other in the fridge (+4 to +8 oC). These samples were submitted to serial analysis at 30 minutes, 1 hour and 2 hours after the initial analysis. Results: Two hundred arterial blood gas results from 25 patients were analysed. The mean values of PaO2, PaCO2, HCO3-, Na+, K+, Ca2+ and lactate at 0 minutes, 30 minutes, 1 hour and 2 hours were not signifi cantly different between the two alternatives of storage. However, within each group, signifi cant changes were found over time for PaO2, K+, Na+, Ca2+ and lactate. Conclusions: When using plastic syringes, arterial blood gas analysis should be processed shortly after collecting the sample. Despite the fact that low temperatures can slow down the metabolism, neither the ice nor the fridge preserved all the sample parameters. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-08-08T10:00:40Z 2012 2012-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.16/1274 |
url |
http://hdl.handle.net/10400.16/1274 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
N Z J Med Lab Sci 2012; 66: 42-45 1171-0195 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
N Z J Med Lab Sci |
publisher.none.fl_str_mv |
N Z J Med Lab Sci |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133639022215168 |