Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate): Carboxylated Graphene Modified Graphite Electrode
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000600001 |
Resumo: | A modified electrode is fabricated by the electrodeposition of polyaniline-polystyrene sulphonate composite onto the carboxylated graphene modified graphite electrode for the detection of hydrogen peroxide (H2O2). The modified electrode displayed excellent catalytic response to the reduction of hydrogen peroxide in neutral pH. It was found that the presence of carboxylated graphene in the sensor system could effectively increase the electron transfer rate and stability. The modified electrode was characterized by cyclic voltammetry, electrochemical impedance spectroscopy and atomic force microscopy. Chronoamperometric studies showed the linear relationship between the reduction peak current and the concentration of H2O2 in the range 25 to 350 μM(R =0.995) with the detection limit of 1×10-6 mol/L (S/N=3). Further, electrochemical analysis of H2O2 in the presence of common interferents such as dopamine, uric acid and ascorbic acid with the modified electrode reveals that there is no overlapping signal from the interferents. |
id |
RCAP_55fd1dc63684af8754a45c984cb30644 |
---|---|
oai_identifier_str |
oai:scielo:S0872-19042012000600001 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate): Carboxylated Graphene Modified Graphite Electrodecarboxylated grapheneelectropolymerizatonhydrogen peroxidepolyanilinepoly(styrene sulphonate)A modified electrode is fabricated by the electrodeposition of polyaniline-polystyrene sulphonate composite onto the carboxylated graphene modified graphite electrode for the detection of hydrogen peroxide (H2O2). The modified electrode displayed excellent catalytic response to the reduction of hydrogen peroxide in neutral pH. It was found that the presence of carboxylated graphene in the sensor system could effectively increase the electron transfer rate and stability. The modified electrode was characterized by cyclic voltammetry, electrochemical impedance spectroscopy and atomic force microscopy. Chronoamperometric studies showed the linear relationship between the reduction peak current and the concentration of H2O2 in the range 25 to 350 μM(R =0.995) with the detection limit of 1×10-6 mol/L (S/N=3). Further, electrochemical analysis of H2O2 in the presence of common interferents such as dopamine, uric acid and ascorbic acid with the modified electrode reveals that there is no overlapping signal from the interferents.Sociedade Portuguesa de Electroquímica2012-11-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000600001Portugaliae Electrochimica Acta v.30 n.6 2012reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000600001Prasannakumar,S.Manjunatha,R.Nethravathi,C.Suresh,G. S.Rajamathib,M.Venkateshad,T. V.info:eu-repo/semantics/openAccess2024-02-06T17:07:11Zoai:scielo:S0872-19042012000600001Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:20:13.151559Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate): Carboxylated Graphene Modified Graphite Electrode |
title |
Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate): Carboxylated Graphene Modified Graphite Electrode |
spellingShingle |
Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate): Carboxylated Graphene Modified Graphite Electrode Prasannakumar,S. carboxylated graphene electropolymerizaton hydrogen peroxide polyaniline poly(styrene sulphonate) |
title_short |
Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate): Carboxylated Graphene Modified Graphite Electrode |
title_full |
Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate): Carboxylated Graphene Modified Graphite Electrode |
title_fullStr |
Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate): Carboxylated Graphene Modified Graphite Electrode |
title_full_unstemmed |
Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate): Carboxylated Graphene Modified Graphite Electrode |
title_sort |
Non-enzymatic Reduction of Hydrogen Peroxide Sensor Based on (Polyaniline-polystyrene Sulphonate): Carboxylated Graphene Modified Graphite Electrode |
author |
Prasannakumar,S. |
author_facet |
Prasannakumar,S. Manjunatha,R. Nethravathi,C. Suresh,G. S. Rajamathib,M. Venkateshad,T. V. |
author_role |
author |
author2 |
Manjunatha,R. Nethravathi,C. Suresh,G. S. Rajamathib,M. Venkateshad,T. V. |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Prasannakumar,S. Manjunatha,R. Nethravathi,C. Suresh,G. S. Rajamathib,M. Venkateshad,T. V. |
dc.subject.por.fl_str_mv |
carboxylated graphene electropolymerizaton hydrogen peroxide polyaniline poly(styrene sulphonate) |
topic |
carboxylated graphene electropolymerizaton hydrogen peroxide polyaniline poly(styrene sulphonate) |
description |
A modified electrode is fabricated by the electrodeposition of polyaniline-polystyrene sulphonate composite onto the carboxylated graphene modified graphite electrode for the detection of hydrogen peroxide (H2O2). The modified electrode displayed excellent catalytic response to the reduction of hydrogen peroxide in neutral pH. It was found that the presence of carboxylated graphene in the sensor system could effectively increase the electron transfer rate and stability. The modified electrode was characterized by cyclic voltammetry, electrochemical impedance spectroscopy and atomic force microscopy. Chronoamperometric studies showed the linear relationship between the reduction peak current and the concentration of H2O2 in the range 25 to 350 μM(R =0.995) with the detection limit of 1×10-6 mol/L (S/N=3). Further, electrochemical analysis of H2O2 in the presence of common interferents such as dopamine, uric acid and ascorbic acid with the modified electrode reveals that there is no overlapping signal from the interferents. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-11-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000600001 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000600001 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042012000600001 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
dc.source.none.fl_str_mv |
Portugaliae Electrochimica Acta v.30 n.6 2012 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137290939793408 |