Automatic segmentation of the carotid artery in ultrasound B-mode images

Detalhes bibliográficos
Autor(a) principal: André M. F. Santos
Data de Publicação: 2013
Outros Autores: João Manuel R. S. Tavares, Elsa Azevedo, Luísa Sousa
Tipo de documento: Livro
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://hdl.handle.net/10216/67098
Resumo: B-mode ultrasound imaging is well-known and used in the medical imaging field; however, it presents various difficulties, specifically in tasks of image segmentation and surface reconstruction, due to intrinsic adverse characteristics, such like low contrast and noise [1,2]. Despite this, B-mode ultrasound imaging has been used in the diagnosis of several cardiac diseases, particularly, carotid artery diseases like atherosclerosis, known as the hardening of the artery, after the accumulation of fatty substances, i.e. lipoproteins, in the artery walls, known as plaques. In this work, an anisotropic diffusion filter is used for speckle removal, and morphological operators are employed in the detection of the artery. The obtained information is used in the definition of two initial contours, one for the lumen and another for the bifurcation boundaries, used to initiate a Chan-Vese-based segmentation method.
id RCAP_577b180dafbfa7b544019fd9aa7aa21c
oai_identifier_str oai:repositorio-aberto.up.pt:10216/67098
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Automatic segmentation of the carotid artery in ultrasound B-mode imagesCiências Tecnológicas, Ciências da engenharia e tecnologiasTechnological sciences, Engineering and technologyB-mode ultrasound imaging is well-known and used in the medical imaging field; however, it presents various difficulties, specifically in tasks of image segmentation and surface reconstruction, due to intrinsic adverse characteristics, such like low contrast and noise [1,2]. Despite this, B-mode ultrasound imaging has been used in the diagnosis of several cardiac diseases, particularly, carotid artery diseases like atherosclerosis, known as the hardening of the artery, after the accumulation of fatty substances, i.e. lipoproteins, in the artery walls, known as plaques. In this work, an anisotropic diffusion filter is used for speckle removal, and morphological operators are employed in the detection of the artery. The obtained information is used in the definition of two initial contours, one for the lumen and another for the bifurcation boundaries, used to initiate a Chan-Vese-based segmentation method.20132013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bookapplication/pdfhttps://hdl.handle.net/10216/67098engAndré M. F. SantosJoão Manuel R. S. TavaresElsa AzevedoLuísa Sousainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-29T13:32:55Zoai:repositorio-aberto.up.pt:10216/67098Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T23:42:24.298810Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Automatic segmentation of the carotid artery in ultrasound B-mode images
title Automatic segmentation of the carotid artery in ultrasound B-mode images
spellingShingle Automatic segmentation of the carotid artery in ultrasound B-mode images
André M. F. Santos
Ciências Tecnológicas, Ciências da engenharia e tecnologias
Technological sciences, Engineering and technology
title_short Automatic segmentation of the carotid artery in ultrasound B-mode images
title_full Automatic segmentation of the carotid artery in ultrasound B-mode images
title_fullStr Automatic segmentation of the carotid artery in ultrasound B-mode images
title_full_unstemmed Automatic segmentation of the carotid artery in ultrasound B-mode images
title_sort Automatic segmentation of the carotid artery in ultrasound B-mode images
author André M. F. Santos
author_facet André M. F. Santos
João Manuel R. S. Tavares
Elsa Azevedo
Luísa Sousa
author_role author
author2 João Manuel R. S. Tavares
Elsa Azevedo
Luísa Sousa
author2_role author
author
author
dc.contributor.author.fl_str_mv André M. F. Santos
João Manuel R. S. Tavares
Elsa Azevedo
Luísa Sousa
dc.subject.por.fl_str_mv Ciências Tecnológicas, Ciências da engenharia e tecnologias
Technological sciences, Engineering and technology
topic Ciências Tecnológicas, Ciências da engenharia e tecnologias
Technological sciences, Engineering and technology
description B-mode ultrasound imaging is well-known and used in the medical imaging field; however, it presents various difficulties, specifically in tasks of image segmentation and surface reconstruction, due to intrinsic adverse characteristics, such like low contrast and noise [1,2]. Despite this, B-mode ultrasound imaging has been used in the diagnosis of several cardiac diseases, particularly, carotid artery diseases like atherosclerosis, known as the hardening of the artery, after the accumulation of fatty substances, i.e. lipoproteins, in the artery walls, known as plaques. In this work, an anisotropic diffusion filter is used for speckle removal, and morphological operators are employed in the detection of the artery. The obtained information is used in the definition of two initial contours, one for the lumen and another for the bifurcation boundaries, used to initiate a Chan-Vese-based segmentation method.
publishDate 2013
dc.date.none.fl_str_mv 2013
2013-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/book
format book
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10216/67098
url https://hdl.handle.net/10216/67098
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799135738940358656