In silico validation of personalized safe intervals for carbohydrate counting errors

Detalhes bibliográficos
Autor(a) principal: Amorim, D?bora
Data de Publicação: 2023
Outros Autores: Miranda, Francisco, Abreu, Carlos
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/20.500.11960/3864
Resumo: For patients with Type 1 diabetes mellitus (T1DM), accurate carbohydrate counting (CC) is essential for successful blood glucose regulation. Unfortunately, mistakes are common and may lead to an incorrect dosage of prandial insulin. In this work, we aim to demonstrate that each person has their own limits for CC errors, which can be computed using patient-specific data. To validate the proposed method, we tested it using several scenarios to investigate the effect of different CC errors on postprandial blood glucose. Virtual subjects from the T1DM Simulator were used in a clinical trial involving 450 meals over 90 days, all following the same daily meal plan but with different intervals for CC errors near, below, and above the limit computed for each patient. The results show that CC errors within personalized limits led to acceptable postprandial glycemic fluctuations. In contrast, experiments where 50% and 97.5% of the meals present a CC error outside the computed safe interval revealed a pronounced degradation of the time in range. Given these results, we consider the proposed method for obtaining personalized limits for CC errors an excellent starting point for an initial assessment of patients? capabilities in CC and to provide appropriate ongoing education.
id RCAP_582dfc7695b56a17852b010cc9fb01f6
oai_identifier_str oai:repositorio.ipvc.pt:20.500.11960/3864
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling In silico validation of personalized safe intervals for carbohydrate counting errorsType 1 diabetes mellitusInsulin therapyPersonalized medicineCarbohydrate counting errorsFor patients with Type 1 diabetes mellitus (T1DM), accurate carbohydrate counting (CC) is essential for successful blood glucose regulation. Unfortunately, mistakes are common and may lead to an incorrect dosage of prandial insulin. In this work, we aim to demonstrate that each person has their own limits for CC errors, which can be computed using patient-specific data. To validate the proposed method, we tested it using several scenarios to investigate the effect of different CC errors on postprandial blood glucose. Virtual subjects from the T1DM Simulator were used in a clinical trial involving 450 meals over 90 days, all following the same daily meal plan but with different intervals for CC errors near, below, and above the limit computed for each patient. The results show that CC errors within personalized limits led to acceptable postprandial glycemic fluctuations. In contrast, experiments where 50% and 97.5% of the meals present a CC error outside the computed safe interval revealed a pronounced degradation of the time in range. Given these results, we consider the proposed method for obtaining personalized limits for CC errors an excellent starting point for an initial assessment of patients? capabilities in CC and to provide appropriate ongoing education.2024-01-19T15:24:19Z2023-01-01T00:00:00Z20232024-01-18T20:02:57Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/20.500.11960/3864eng2072-664310.3390/nu15194110Amorim, D?boraMiranda, FranciscoAbreu, Carlosinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-25T09:01:17Zoai:repositorio.ipvc.pt:20.500.11960/3864Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T01:57:02.414680Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv In silico validation of personalized safe intervals for carbohydrate counting errors
title In silico validation of personalized safe intervals for carbohydrate counting errors
spellingShingle In silico validation of personalized safe intervals for carbohydrate counting errors
Amorim, D?bora
Type 1 diabetes mellitus
Insulin therapy
Personalized medicine
Carbohydrate counting errors
title_short In silico validation of personalized safe intervals for carbohydrate counting errors
title_full In silico validation of personalized safe intervals for carbohydrate counting errors
title_fullStr In silico validation of personalized safe intervals for carbohydrate counting errors
title_full_unstemmed In silico validation of personalized safe intervals for carbohydrate counting errors
title_sort In silico validation of personalized safe intervals for carbohydrate counting errors
author Amorim, D?bora
author_facet Amorim, D?bora
Miranda, Francisco
Abreu, Carlos
author_role author
author2 Miranda, Francisco
Abreu, Carlos
author2_role author
author
dc.contributor.author.fl_str_mv Amorim, D?bora
Miranda, Francisco
Abreu, Carlos
dc.subject.por.fl_str_mv Type 1 diabetes mellitus
Insulin therapy
Personalized medicine
Carbohydrate counting errors
topic Type 1 diabetes mellitus
Insulin therapy
Personalized medicine
Carbohydrate counting errors
description For patients with Type 1 diabetes mellitus (T1DM), accurate carbohydrate counting (CC) is essential for successful blood glucose regulation. Unfortunately, mistakes are common and may lead to an incorrect dosage of prandial insulin. In this work, we aim to demonstrate that each person has their own limits for CC errors, which can be computed using patient-specific data. To validate the proposed method, we tested it using several scenarios to investigate the effect of different CC errors on postprandial blood glucose. Virtual subjects from the T1DM Simulator were used in a clinical trial involving 450 meals over 90 days, all following the same daily meal plan but with different intervals for CC errors near, below, and above the limit computed for each patient. The results show that CC errors within personalized limits led to acceptable postprandial glycemic fluctuations. In contrast, experiments where 50% and 97.5% of the meals present a CC error outside the computed safe interval revealed a pronounced degradation of the time in range. Given these results, we consider the proposed method for obtaining personalized limits for CC errors an excellent starting point for an initial assessment of patients? capabilities in CC and to provide appropriate ongoing education.
publishDate 2023
dc.date.none.fl_str_mv 2023-01-01T00:00:00Z
2023
2024-01-19T15:24:19Z
2024-01-18T20:02:57Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/20.500.11960/3864
url http://hdl.handle.net/20.500.11960/3864
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 2072-6643
10.3390/nu15194110
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799137057770045440