MHSP with position detection capability

Detalhes bibliográficos
Autor(a) principal: Luz, H. Natal da
Data de Publicação: 2007
Outros Autores: Veloso, J. F. C. A., Mendes, N. F. C., Santos, J. M. F. dos, Mir, J. A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/4379
https://doi.org/10.1016/j.nima.2006.10.243
Resumo: The first implementation of a position sensitive readout for a Micro Hole and Strip Plate (MHSP) is described and tested. The readout consists on a resistive layer crossing the anodes and connected to a preamplifier on each side. By weighing the charge pulses on both preamplifiers it is possible to determine the interaction point. A 100-200 [Omega] resistance layer between consecutive strips was found to be the best compromise between position linearity and energy resolution. Preliminary results using 22.1 keV X-rays present a good linearity between the measured and the actual position with a mean deviation of about 0.15 mm and a position resolution of 1.6 mm full-width at half-maximum (FWHM), being limited by the analogue division electronic circuit. The performance of the MHSP position detector will be presented and discussed for 1D readout.
id RCAP_5ca97a53bfe83cb81f6e5826e80f4c40
oai_identifier_str oai:estudogeral.uc.pt:10316/4379
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling MHSP with position detection capabilityMicro Hole and Strip PlateGas Electron MultiplierX-ray detectorPosition sensitiveResistive charge divisionAnalogue divisionThe first implementation of a position sensitive readout for a Micro Hole and Strip Plate (MHSP) is described and tested. The readout consists on a resistive layer crossing the anodes and connected to a preamplifier on each side. By weighing the charge pulses on both preamplifiers it is possible to determine the interaction point. A 100-200 [Omega] resistance layer between consecutive strips was found to be the best compromise between position linearity and energy resolution. Preliminary results using 22.1 keV X-rays present a good linearity between the measured and the actual position with a mean deviation of about 0.15 mm and a position resolution of 1.6 mm full-width at half-maximum (FWHM), being limited by the analogue division electronic circuit. The performance of the MHSP position detector will be presented and discussed for 1D readout.http://www.sciencedirect.com/science/article/B6TJM-4MCW883-6/1/e528f681f383637223dd897e6767bb5d2007info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/4379http://hdl.handle.net/10316/4379https://doi.org/10.1016/j.nima.2006.10.243engNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 573:1-2 (2007) 191-194Luz, H. Natal daVeloso, J. F. C. A.Mendes, N. F. C.Santos, J. M. F. dosMir, J. A.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-05-25T03:13:01Zoai:estudogeral.uc.pt:10316/4379Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:43.695307Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv MHSP with position detection capability
title MHSP with position detection capability
spellingShingle MHSP with position detection capability
Luz, H. Natal da
Micro Hole and Strip Plate
Gas Electron Multiplier
X-ray detector
Position sensitive
Resistive charge division
Analogue division
title_short MHSP with position detection capability
title_full MHSP with position detection capability
title_fullStr MHSP with position detection capability
title_full_unstemmed MHSP with position detection capability
title_sort MHSP with position detection capability
author Luz, H. Natal da
author_facet Luz, H. Natal da
Veloso, J. F. C. A.
Mendes, N. F. C.
Santos, J. M. F. dos
Mir, J. A.
author_role author
author2 Veloso, J. F. C. A.
Mendes, N. F. C.
Santos, J. M. F. dos
Mir, J. A.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Luz, H. Natal da
Veloso, J. F. C. A.
Mendes, N. F. C.
Santos, J. M. F. dos
Mir, J. A.
dc.subject.por.fl_str_mv Micro Hole and Strip Plate
Gas Electron Multiplier
X-ray detector
Position sensitive
Resistive charge division
Analogue division
topic Micro Hole and Strip Plate
Gas Electron Multiplier
X-ray detector
Position sensitive
Resistive charge division
Analogue division
description The first implementation of a position sensitive readout for a Micro Hole and Strip Plate (MHSP) is described and tested. The readout consists on a resistive layer crossing the anodes and connected to a preamplifier on each side. By weighing the charge pulses on both preamplifiers it is possible to determine the interaction point. A 100-200 [Omega] resistance layer between consecutive strips was found to be the best compromise between position linearity and energy resolution. Preliminary results using 22.1 keV X-rays present a good linearity between the measured and the actual position with a mean deviation of about 0.15 mm and a position resolution of 1.6 mm full-width at half-maximum (FWHM), being limited by the analogue division electronic circuit. The performance of the MHSP position detector will be presented and discussed for 1D readout.
publishDate 2007
dc.date.none.fl_str_mv 2007
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/4379
http://hdl.handle.net/10316/4379
https://doi.org/10.1016/j.nima.2006.10.243
url http://hdl.handle.net/10316/4379
https://doi.org/10.1016/j.nima.2006.10.243
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 573:1-2 (2007) 191-194
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv aplication/PDF
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133888326402048