MHSP with position detection capability
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10316/4379 https://doi.org/10.1016/j.nima.2006.10.243 |
Resumo: | The first implementation of a position sensitive readout for a Micro Hole and Strip Plate (MHSP) is described and tested. The readout consists on a resistive layer crossing the anodes and connected to a preamplifier on each side. By weighing the charge pulses on both preamplifiers it is possible to determine the interaction point. A 100-200 [Omega] resistance layer between consecutive strips was found to be the best compromise between position linearity and energy resolution. Preliminary results using 22.1 keV X-rays present a good linearity between the measured and the actual position with a mean deviation of about 0.15 mm and a position resolution of 1.6 mm full-width at half-maximum (FWHM), being limited by the analogue division electronic circuit. The performance of the MHSP position detector will be presented and discussed for 1D readout. |
id |
RCAP_5ca97a53bfe83cb81f6e5826e80f4c40 |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/4379 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
MHSP with position detection capabilityMicro Hole and Strip PlateGas Electron MultiplierX-ray detectorPosition sensitiveResistive charge divisionAnalogue divisionThe first implementation of a position sensitive readout for a Micro Hole and Strip Plate (MHSP) is described and tested. The readout consists on a resistive layer crossing the anodes and connected to a preamplifier on each side. By weighing the charge pulses on both preamplifiers it is possible to determine the interaction point. A 100-200 [Omega] resistance layer between consecutive strips was found to be the best compromise between position linearity and energy resolution. Preliminary results using 22.1 keV X-rays present a good linearity between the measured and the actual position with a mean deviation of about 0.15 mm and a position resolution of 1.6 mm full-width at half-maximum (FWHM), being limited by the analogue division electronic circuit. The performance of the MHSP position detector will be presented and discussed for 1D readout.http://www.sciencedirect.com/science/article/B6TJM-4MCW883-6/1/e528f681f383637223dd897e6767bb5d2007info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/4379http://hdl.handle.net/10316/4379https://doi.org/10.1016/j.nima.2006.10.243engNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 573:1-2 (2007) 191-194Luz, H. Natal daVeloso, J. F. C. A.Mendes, N. F. C.Santos, J. M. F. dosMir, J. A.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-05-25T03:13:01Zoai:estudogeral.uc.pt:10316/4379Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:43.695307Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
MHSP with position detection capability |
title |
MHSP with position detection capability |
spellingShingle |
MHSP with position detection capability Luz, H. Natal da Micro Hole and Strip Plate Gas Electron Multiplier X-ray detector Position sensitive Resistive charge division Analogue division |
title_short |
MHSP with position detection capability |
title_full |
MHSP with position detection capability |
title_fullStr |
MHSP with position detection capability |
title_full_unstemmed |
MHSP with position detection capability |
title_sort |
MHSP with position detection capability |
author |
Luz, H. Natal da |
author_facet |
Luz, H. Natal da Veloso, J. F. C. A. Mendes, N. F. C. Santos, J. M. F. dos Mir, J. A. |
author_role |
author |
author2 |
Veloso, J. F. C. A. Mendes, N. F. C. Santos, J. M. F. dos Mir, J. A. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Luz, H. Natal da Veloso, J. F. C. A. Mendes, N. F. C. Santos, J. M. F. dos Mir, J. A. |
dc.subject.por.fl_str_mv |
Micro Hole and Strip Plate Gas Electron Multiplier X-ray detector Position sensitive Resistive charge division Analogue division |
topic |
Micro Hole and Strip Plate Gas Electron Multiplier X-ray detector Position sensitive Resistive charge division Analogue division |
description |
The first implementation of a position sensitive readout for a Micro Hole and Strip Plate (MHSP) is described and tested. The readout consists on a resistive layer crossing the anodes and connected to a preamplifier on each side. By weighing the charge pulses on both preamplifiers it is possible to determine the interaction point. A 100-200 [Omega] resistance layer between consecutive strips was found to be the best compromise between position linearity and energy resolution. Preliminary results using 22.1 keV X-rays present a good linearity between the measured and the actual position with a mean deviation of about 0.15 mm and a position resolution of 1.6 mm full-width at half-maximum (FWHM), being limited by the analogue division electronic circuit. The performance of the MHSP position detector will be presented and discussed for 1D readout. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/4379 http://hdl.handle.net/10316/4379 https://doi.org/10.1016/j.nima.2006.10.243 |
url |
http://hdl.handle.net/10316/4379 https://doi.org/10.1016/j.nima.2006.10.243 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 573:1-2 (2007) 191-194 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
aplication/PDF |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133888326402048 |