Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.14/38914 |
Resumo: | Guaranteeing peripheral venous access is one of the cornerstones of modern healthcare. Recent evidence shows that the lack of adequate clinical devices can result in the provision of substandard care to patients who require peripheral intravenous catheterization (PIVC). To address this challenge, we aimed to develop a PIVC pack for adult patients and assess the usability of this new device. Methods: Following a mix-method design, the PIVC pack development and usability assessment were performed in two phases with the involvement of its potential end-users (nurses). In phase one (concept and semi-functional prototype assessment), focus group rounds were conducted, and a usability assessment questionnaire was applied at each stage. In phase two (pre-clinical usability assessment), a two-arm crossover randomised controlled trial (PIVC pack versus traditional material) was conducted with nurses in a simulated setting. Final interviews were conducted to further explore the PIVC pack applicability in a real-life clinical setting. Results: High average usability scores were identified in each study phase. During the pre-clinical usability assessment, the PIVC pack significantly reduced procedural time (Z = −2.482, p = 0.013) and avoided omissions while preparing the required material (Z = −1.977, p = 0.048). The participating nurses emphasised the pack’s potential to standardise practices among professionals, improve adherence to infection control recommendations, and enhance stock management. Conclusions: The developed pack appears to be a promising device that can assist healthcare professionals in providing efficient and safe care to patients requiring a PIVC. Future studies in real clinical settings are warranted to test its cost-effectiveness. |
id |
RCAP_5ff9c74a01cfc80548a0d2a47bea50c3 |
---|---|
oai_identifier_str |
oai:repositorio.ucp.pt:10400.14/38914 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method studyCatheterisationPeripheralMedical deviceUsability testingNursesGuaranteeing peripheral venous access is one of the cornerstones of modern healthcare. Recent evidence shows that the lack of adequate clinical devices can result in the provision of substandard care to patients who require peripheral intravenous catheterization (PIVC). To address this challenge, we aimed to develop a PIVC pack for adult patients and assess the usability of this new device. Methods: Following a mix-method design, the PIVC pack development and usability assessment were performed in two phases with the involvement of its potential end-users (nurses). In phase one (concept and semi-functional prototype assessment), focus group rounds were conducted, and a usability assessment questionnaire was applied at each stage. In phase two (pre-clinical usability assessment), a two-arm crossover randomised controlled trial (PIVC pack versus traditional material) was conducted with nurses in a simulated setting. Final interviews were conducted to further explore the PIVC pack applicability in a real-life clinical setting. Results: High average usability scores were identified in each study phase. During the pre-clinical usability assessment, the PIVC pack significantly reduced procedural time (Z = −2.482, p = 0.013) and avoided omissions while preparing the required material (Z = −1.977, p = 0.048). The participating nurses emphasised the pack’s potential to standardise practices among professionals, improve adherence to infection control recommendations, and enhance stock management. Conclusions: The developed pack appears to be a promising device that can assist healthcare professionals in providing efficient and safe care to patients requiring a PIVC. Future studies in real clinical settings are warranted to test its cost-effectiveness.Veritati - Repositório Institucional da Universidade Católica PortuguesaSantos-Costa, PauloAlves, MarianaSousa, CarolinaSousa, Liliana B.Paiva-Santos, FilipeBernardes, Rafael A.Ventura, FilipaSalgueiro-Oliveira, AnabelaParreira, PedroVieira, MargaridaGraveto, João2022-09-16T10:23:11Z2022-09-052022-09-05T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.14/38914eng1661-782710.3390/ijerph19171113085137586186PMC951781936078842000851189300001info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-16T01:44:42Zoai:repositorio.ucp.pt:10400.14/38914Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:31:47.286433Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study |
title |
Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study |
spellingShingle |
Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study Santos-Costa, Paulo Catheterisation Peripheral Medical device Usability testing Nurses |
title_short |
Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study |
title_full |
Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study |
title_fullStr |
Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study |
title_full_unstemmed |
Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study |
title_sort |
Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study |
author |
Santos-Costa, Paulo |
author_facet |
Santos-Costa, Paulo Alves, Mariana Sousa, Carolina Sousa, Liliana B. Paiva-Santos, Filipe Bernardes, Rafael A. Ventura, Filipa Salgueiro-Oliveira, Anabela Parreira, Pedro Vieira, Margarida Graveto, João |
author_role |
author |
author2 |
Alves, Mariana Sousa, Carolina Sousa, Liliana B. Paiva-Santos, Filipe Bernardes, Rafael A. Ventura, Filipa Salgueiro-Oliveira, Anabela Parreira, Pedro Vieira, Margarida Graveto, João |
author2_role |
author author author author author author author author author author |
dc.contributor.none.fl_str_mv |
Veritati - Repositório Institucional da Universidade Católica Portuguesa |
dc.contributor.author.fl_str_mv |
Santos-Costa, Paulo Alves, Mariana Sousa, Carolina Sousa, Liliana B. Paiva-Santos, Filipe Bernardes, Rafael A. Ventura, Filipa Salgueiro-Oliveira, Anabela Parreira, Pedro Vieira, Margarida Graveto, João |
dc.subject.por.fl_str_mv |
Catheterisation Peripheral Medical device Usability testing Nurses |
topic |
Catheterisation Peripheral Medical device Usability testing Nurses |
description |
Guaranteeing peripheral venous access is one of the cornerstones of modern healthcare. Recent evidence shows that the lack of adequate clinical devices can result in the provision of substandard care to patients who require peripheral intravenous catheterization (PIVC). To address this challenge, we aimed to develop a PIVC pack for adult patients and assess the usability of this new device. Methods: Following a mix-method design, the PIVC pack development and usability assessment were performed in two phases with the involvement of its potential end-users (nurses). In phase one (concept and semi-functional prototype assessment), focus group rounds were conducted, and a usability assessment questionnaire was applied at each stage. In phase two (pre-clinical usability assessment), a two-arm crossover randomised controlled trial (PIVC pack versus traditional material) was conducted with nurses in a simulated setting. Final interviews were conducted to further explore the PIVC pack applicability in a real-life clinical setting. Results: High average usability scores were identified in each study phase. During the pre-clinical usability assessment, the PIVC pack significantly reduced procedural time (Z = −2.482, p = 0.013) and avoided omissions while preparing the required material (Z = −1.977, p = 0.048). The participating nurses emphasised the pack’s potential to standardise practices among professionals, improve adherence to infection control recommendations, and enhance stock management. Conclusions: The developed pack appears to be a promising device that can assist healthcare professionals in providing efficient and safe care to patients requiring a PIVC. Future studies in real clinical settings are warranted to test its cost-effectiveness. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-09-16T10:23:11Z 2022-09-05 2022-09-05T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.14/38914 |
url |
http://hdl.handle.net/10400.14/38914 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
1661-7827 10.3390/ijerph191711130 85137586186 PMC9517819 36078842 000851189300001 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132041579593728 |