Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study

Detalhes bibliográficos
Autor(a) principal: Santos-Costa, Paulo
Data de Publicação: 2022
Outros Autores: Alves, Mariana, Sousa, Carolina, Sousa, Liliana B., Paiva-Santos, Filipe, Bernardes, Rafael A., Ventura, Filipa, Salgueiro-Oliveira, Anabela, Parreira, Pedro, Vieira, Margarida, Graveto, João
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.14/38914
Resumo: Guaranteeing peripheral venous access is one of the cornerstones of modern healthcare. Recent evidence shows that the lack of adequate clinical devices can result in the provision of substandard care to patients who require peripheral intravenous catheterization (PIVC). To address this challenge, we aimed to develop a PIVC pack for adult patients and assess the usability of this new device. Methods: Following a mix-method design, the PIVC pack development and usability assessment were performed in two phases with the involvement of its potential end-users (nurses). In phase one (concept and semi-functional prototype assessment), focus group rounds were conducted, and a usability assessment questionnaire was applied at each stage. In phase two (pre-clinical usability assessment), a two-arm crossover randomised controlled trial (PIVC pack versus traditional material) was conducted with nurses in a simulated setting. Final interviews were conducted to further explore the PIVC pack applicability in a real-life clinical setting. Results: High average usability scores were identified in each study phase. During the pre-clinical usability assessment, the PIVC pack significantly reduced procedural time (Z = −2.482, p = 0.013) and avoided omissions while preparing the required material (Z = −1.977, p = 0.048). The participating nurses emphasised the pack’s potential to standardise practices among professionals, improve adherence to infection control recommendations, and enhance stock management. Conclusions: The developed pack appears to be a promising device that can assist healthcare professionals in providing efficient and safe care to patients requiring a PIVC. Future studies in real clinical settings are warranted to test its cost-effectiveness.
id RCAP_5ff9c74a01cfc80548a0d2a47bea50c3
oai_identifier_str oai:repositorio.ucp.pt:10400.14/38914
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method studyCatheterisationPeripheralMedical deviceUsability testingNursesGuaranteeing peripheral venous access is one of the cornerstones of modern healthcare. Recent evidence shows that the lack of adequate clinical devices can result in the provision of substandard care to patients who require peripheral intravenous catheterization (PIVC). To address this challenge, we aimed to develop a PIVC pack for adult patients and assess the usability of this new device. Methods: Following a mix-method design, the PIVC pack development and usability assessment were performed in two phases with the involvement of its potential end-users (nurses). In phase one (concept and semi-functional prototype assessment), focus group rounds were conducted, and a usability assessment questionnaire was applied at each stage. In phase two (pre-clinical usability assessment), a two-arm crossover randomised controlled trial (PIVC pack versus traditional material) was conducted with nurses in a simulated setting. Final interviews were conducted to further explore the PIVC pack applicability in a real-life clinical setting. Results: High average usability scores were identified in each study phase. During the pre-clinical usability assessment, the PIVC pack significantly reduced procedural time (Z = −2.482, p = 0.013) and avoided omissions while preparing the required material (Z = −1.977, p = 0.048). The participating nurses emphasised the pack’s potential to standardise practices among professionals, improve adherence to infection control recommendations, and enhance stock management. Conclusions: The developed pack appears to be a promising device that can assist healthcare professionals in providing efficient and safe care to patients requiring a PIVC. Future studies in real clinical settings are warranted to test its cost-effectiveness.Veritati - Repositório Institucional da Universidade Católica PortuguesaSantos-Costa, PauloAlves, MarianaSousa, CarolinaSousa, Liliana B.Paiva-Santos, FilipeBernardes, Rafael A.Ventura, FilipaSalgueiro-Oliveira, AnabelaParreira, PedroVieira, MargaridaGraveto, João2022-09-16T10:23:11Z2022-09-052022-09-05T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.14/38914eng1661-782710.3390/ijerph19171113085137586186PMC951781936078842000851189300001info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-16T01:44:42Zoai:repositorio.ucp.pt:10400.14/38914Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:31:47.286433Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study
title Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study
spellingShingle Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study
Santos-Costa, Paulo
Catheterisation
Peripheral
Medical device
Usability testing
Nurses
title_short Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study
title_full Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study
title_fullStr Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study
title_full_unstemmed Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study
title_sort Nurses' involvement in the development and usability assessment of an innovative peripheral intravenous catheterisation pack: a mix-method study
author Santos-Costa, Paulo
author_facet Santos-Costa, Paulo
Alves, Mariana
Sousa, Carolina
Sousa, Liliana B.
Paiva-Santos, Filipe
Bernardes, Rafael A.
Ventura, Filipa
Salgueiro-Oliveira, Anabela
Parreira, Pedro
Vieira, Margarida
Graveto, João
author_role author
author2 Alves, Mariana
Sousa, Carolina
Sousa, Liliana B.
Paiva-Santos, Filipe
Bernardes, Rafael A.
Ventura, Filipa
Salgueiro-Oliveira, Anabela
Parreira, Pedro
Vieira, Margarida
Graveto, João
author2_role author
author
author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Veritati - Repositório Institucional da Universidade Católica Portuguesa
dc.contributor.author.fl_str_mv Santos-Costa, Paulo
Alves, Mariana
Sousa, Carolina
Sousa, Liliana B.
Paiva-Santos, Filipe
Bernardes, Rafael A.
Ventura, Filipa
Salgueiro-Oliveira, Anabela
Parreira, Pedro
Vieira, Margarida
Graveto, João
dc.subject.por.fl_str_mv Catheterisation
Peripheral
Medical device
Usability testing
Nurses
topic Catheterisation
Peripheral
Medical device
Usability testing
Nurses
description Guaranteeing peripheral venous access is one of the cornerstones of modern healthcare. Recent evidence shows that the lack of adequate clinical devices can result in the provision of substandard care to patients who require peripheral intravenous catheterization (PIVC). To address this challenge, we aimed to develop a PIVC pack for adult patients and assess the usability of this new device. Methods: Following a mix-method design, the PIVC pack development and usability assessment were performed in two phases with the involvement of its potential end-users (nurses). In phase one (concept and semi-functional prototype assessment), focus group rounds were conducted, and a usability assessment questionnaire was applied at each stage. In phase two (pre-clinical usability assessment), a two-arm crossover randomised controlled trial (PIVC pack versus traditional material) was conducted with nurses in a simulated setting. Final interviews were conducted to further explore the PIVC pack applicability in a real-life clinical setting. Results: High average usability scores were identified in each study phase. During the pre-clinical usability assessment, the PIVC pack significantly reduced procedural time (Z = −2.482, p = 0.013) and avoided omissions while preparing the required material (Z = −1.977, p = 0.048). The participating nurses emphasised the pack’s potential to standardise practices among professionals, improve adherence to infection control recommendations, and enhance stock management. Conclusions: The developed pack appears to be a promising device that can assist healthcare professionals in providing efficient and safe care to patients requiring a PIVC. Future studies in real clinical settings are warranted to test its cost-effectiveness.
publishDate 2022
dc.date.none.fl_str_mv 2022-09-16T10:23:11Z
2022-09-05
2022-09-05T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.14/38914
url http://hdl.handle.net/10400.14/38914
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1661-7827
10.3390/ijerph191711130
85137586186
PMC9517819
36078842
000851189300001
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132041579593728