Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon
Autor(a) principal: | |
---|---|
Data de Publicação: | 1983 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10316/12904 https://doi.org/10.1109/TNS.1983.4332296 |
Resumo: | An unidimensional Monte Carlo method is used to calculate the secondary scintillation (electroluminescence) intensity in xenon gas proportional scintillation counters. Other transport parameters like electron drift time, average number of collisions, efficiency for light production and induced charge pulse amplitude are also calculated. The values obtained agree well with the experimental data available |
id |
RCAP_62b9f2b8085bc72f5f1a80719d236b79 |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/12904 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Unidimensional Monte Carlo Simulation of the Secondary Scintillation of XenonAn unidimensional Monte Carlo method is used to calculate the secondary scintillation (electroluminescence) intensity in xenon gas proportional scintillation counters. Other transport parameters like electron drift time, average number of collisions, efficiency for light production and induced charge pulse amplitude are also calculated. The values obtained agree well with the experimental data availableIEEE1983-02info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10316/12904http://hdl.handle.net/10316/12904https://doi.org/10.1109/TNS.1983.4332296engIEEE Transactions on Nuclear Science 30:1 (1983) 389-3930018-9499Dias, Teresa H. V. T.Stauffer, A. D.Conde, C. A. N.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2020-11-06T17:00:09Zoai:estudogeral.uc.pt:10316/12904Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:54.582242Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon |
title |
Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon |
spellingShingle |
Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon Dias, Teresa H. V. T. |
title_short |
Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon |
title_full |
Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon |
title_fullStr |
Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon |
title_full_unstemmed |
Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon |
title_sort |
Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon |
author |
Dias, Teresa H. V. T. |
author_facet |
Dias, Teresa H. V. T. Stauffer, A. D. Conde, C. A. N. |
author_role |
author |
author2 |
Stauffer, A. D. Conde, C. A. N. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Dias, Teresa H. V. T. Stauffer, A. D. Conde, C. A. N. |
description |
An unidimensional Monte Carlo method is used to calculate the secondary scintillation (electroluminescence) intensity in xenon gas proportional scintillation counters. Other transport parameters like electron drift time, average number of collisions, efficiency for light production and induced charge pulse amplitude are also calculated. The values obtained agree well with the experimental data available |
publishDate |
1983 |
dc.date.none.fl_str_mv |
1983-02 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/12904 http://hdl.handle.net/10316/12904 https://doi.org/10.1109/TNS.1983.4332296 |
url |
http://hdl.handle.net/10316/12904 https://doi.org/10.1109/TNS.1983.4332296 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
IEEE Transactions on Nuclear Science 30:1 (1983) 389-393 0018-9499 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
IEEE |
publisher.none.fl_str_mv |
IEEE |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133889429504000 |