Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon

Detalhes bibliográficos
Autor(a) principal: Dias, Teresa H. V. T.
Data de Publicação: 1983
Outros Autores: Stauffer, A. D., Conde, C. A. N.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/12904
https://doi.org/10.1109/TNS.1983.4332296
Resumo: An unidimensional Monte Carlo method is used to calculate the secondary scintillation (electroluminescence) intensity in xenon gas proportional scintillation counters. Other transport parameters like electron drift time, average number of collisions, efficiency for light production and induced charge pulse amplitude are also calculated. The values obtained agree well with the experimental data available
id RCAP_62b9f2b8085bc72f5f1a80719d236b79
oai_identifier_str oai:estudogeral.uc.pt:10316/12904
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Unidimensional Monte Carlo Simulation of the Secondary Scintillation of XenonAn unidimensional Monte Carlo method is used to calculate the secondary scintillation (electroluminescence) intensity in xenon gas proportional scintillation counters. Other transport parameters like electron drift time, average number of collisions, efficiency for light production and induced charge pulse amplitude are also calculated. The values obtained agree well with the experimental data availableIEEE1983-02info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10316/12904http://hdl.handle.net/10316/12904https://doi.org/10.1109/TNS.1983.4332296engIEEE Transactions on Nuclear Science 30:1 (1983) 389-3930018-9499Dias, Teresa H. V. T.Stauffer, A. D.Conde, C. A. N.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2020-11-06T17:00:09Zoai:estudogeral.uc.pt:10316/12904Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:54.582242Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon
title Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon
spellingShingle Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon
Dias, Teresa H. V. T.
title_short Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon
title_full Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon
title_fullStr Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon
title_full_unstemmed Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon
title_sort Unidimensional Monte Carlo Simulation of the Secondary Scintillation of Xenon
author Dias, Teresa H. V. T.
author_facet Dias, Teresa H. V. T.
Stauffer, A. D.
Conde, C. A. N.
author_role author
author2 Stauffer, A. D.
Conde, C. A. N.
author2_role author
author
dc.contributor.author.fl_str_mv Dias, Teresa H. V. T.
Stauffer, A. D.
Conde, C. A. N.
description An unidimensional Monte Carlo method is used to calculate the secondary scintillation (electroluminescence) intensity in xenon gas proportional scintillation counters. Other transport parameters like electron drift time, average number of collisions, efficiency for light production and induced charge pulse amplitude are also calculated. The values obtained agree well with the experimental data available
publishDate 1983
dc.date.none.fl_str_mv 1983-02
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/12904
http://hdl.handle.net/10316/12904
https://doi.org/10.1109/TNS.1983.4332296
url http://hdl.handle.net/10316/12904
https://doi.org/10.1109/TNS.1983.4332296
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv IEEE Transactions on Nuclear Science 30:1 (1983) 389-393
0018-9499
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv IEEE
publisher.none.fl_str_mv IEEE
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133889429504000