Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms

Detalhes bibliográficos
Autor(a) principal: Gomes,Catarina
Data de Publicação: 2023
Outros Autores: O’Neill,Catarina, Pinho,Rolando, Barosa,Rita, Ponte,Ana, Magalhães-Costa,Pedro, Rodrigues,Adélia, Chagas,Cristina, Carvalho,João
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://scielo.pt/scielo.php?script=sci_arttext&pid=S2341-45452023000300057
Resumo: Abstract Introduction: The European Society of Gastrointestinal Endoscopy (ESGE) identified the need to benchmark the quality of small bowel capsule endoscopy (SBCE) and produced a set of performance measures (PM). The aim of this study is to critically evaluate the accordance of the PM for SBCE in two Portuguese centers with different SBCE platforms. Methods: The authors conducted a cross-sectional analysis of consecutive SBCE performed in an 18-month period in 2 Portuguese centers that used two different SBCE platforms Mirocam® (IntroMedic, Seoul, South Korea) and PillCam® (Medtronic, Yokneam, Israel). A total of 10 PM (6 key, 4 minor) were evaluated and compared between the 2 centers. Results: A total of 493 SBCE were included. The minimum standard established by ESGE was reached in 3/6 key PM (complete visualization, lesion detection rate, and capsule retention rate), and none of the 4 minor PM. PM compliance significantly differed between the 2 centers: complete small bowel visualization 95.9 and 90% (p = 0.01), diagnostic yield 50.6 and 63% (p = 0.005), adequate small bowel cleansing level according to Brotz scale 69.54 and 84.6% (p ≤ 0.001), patients with high risk of capsule retention offered a patency capsule 4.2 and 73% (p ≤ 0.001), respectively. Conclusion: This study highlights and critically discusses technical and organizational issues that should be considered in defining more realistic PM thresholds, aiming to improve SBCE quality.
id RCAP_67409000b759f09daefd85490a8f3b30
oai_identifier_str oai:scielo:S2341-45452023000300057
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy PlatformsPerformance measuresSmall bowel capsule endoscopyEndoscopic unitsAbstract Introduction: The European Society of Gastrointestinal Endoscopy (ESGE) identified the need to benchmark the quality of small bowel capsule endoscopy (SBCE) and produced a set of performance measures (PM). The aim of this study is to critically evaluate the accordance of the PM for SBCE in two Portuguese centers with different SBCE platforms. Methods: The authors conducted a cross-sectional analysis of consecutive SBCE performed in an 18-month period in 2 Portuguese centers that used two different SBCE platforms Mirocam® (IntroMedic, Seoul, South Korea) and PillCam® (Medtronic, Yokneam, Israel). A total of 10 PM (6 key, 4 minor) were evaluated and compared between the 2 centers. Results: A total of 493 SBCE were included. The minimum standard established by ESGE was reached in 3/6 key PM (complete visualization, lesion detection rate, and capsule retention rate), and none of the 4 minor PM. PM compliance significantly differed between the 2 centers: complete small bowel visualization 95.9 and 90% (p = 0.01), diagnostic yield 50.6 and 63% (p = 0.005), adequate small bowel cleansing level according to Brotz scale 69.54 and 84.6% (p ≤ 0.001), patients with high risk of capsule retention offered a patency capsule 4.2 and 73% (p ≤ 0.001), respectively. Conclusion: This study highlights and critically discusses technical and organizational issues that should be considered in defining more realistic PM thresholds, aiming to improve SBCE quality.Sociedade Portuguesa de Gastrenterologia2023-06-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S2341-45452023000300057GE-Portuguese Journal of Gastroenterology v.30 n.3 2023reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S2341-45452023000300057Gomes,CatarinaO’Neill,CatarinaPinho,RolandoBarosa,RitaPonte,AnaMagalhães-Costa,PedroRodrigues,AdéliaChagas,CristinaCarvalho,Joãoinfo:eu-repo/semantics/openAccess2024-02-06T17:34:24Zoai:scielo:S2341-45452023000300057Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:36:21.664458Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms
title Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms
spellingShingle Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms
Gomes,Catarina
Performance measures
Small bowel capsule endoscopy
Endoscopic units
title_short Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms
title_full Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms
title_fullStr Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms
title_full_unstemmed Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms
title_sort Critical Analysis of the Applicability of Small Bowel Capsule Endoscopy Performance Measures among 2 Portuguese Centers with Different Capsule Endoscopy Platforms
author Gomes,Catarina
author_facet Gomes,Catarina
O’Neill,Catarina
Pinho,Rolando
Barosa,Rita
Ponte,Ana
Magalhães-Costa,Pedro
Rodrigues,Adélia
Chagas,Cristina
Carvalho,João
author_role author
author2 O’Neill,Catarina
Pinho,Rolando
Barosa,Rita
Ponte,Ana
Magalhães-Costa,Pedro
Rodrigues,Adélia
Chagas,Cristina
Carvalho,João
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Gomes,Catarina
O’Neill,Catarina
Pinho,Rolando
Barosa,Rita
Ponte,Ana
Magalhães-Costa,Pedro
Rodrigues,Adélia
Chagas,Cristina
Carvalho,João
dc.subject.por.fl_str_mv Performance measures
Small bowel capsule endoscopy
Endoscopic units
topic Performance measures
Small bowel capsule endoscopy
Endoscopic units
description Abstract Introduction: The European Society of Gastrointestinal Endoscopy (ESGE) identified the need to benchmark the quality of small bowel capsule endoscopy (SBCE) and produced a set of performance measures (PM). The aim of this study is to critically evaluate the accordance of the PM for SBCE in two Portuguese centers with different SBCE platforms. Methods: The authors conducted a cross-sectional analysis of consecutive SBCE performed in an 18-month period in 2 Portuguese centers that used two different SBCE platforms Mirocam® (IntroMedic, Seoul, South Korea) and PillCam® (Medtronic, Yokneam, Israel). A total of 10 PM (6 key, 4 minor) were evaluated and compared between the 2 centers. Results: A total of 493 SBCE were included. The minimum standard established by ESGE was reached in 3/6 key PM (complete visualization, lesion detection rate, and capsule retention rate), and none of the 4 minor PM. PM compliance significantly differed between the 2 centers: complete small bowel visualization 95.9 and 90% (p = 0.01), diagnostic yield 50.6 and 63% (p = 0.005), adequate small bowel cleansing level according to Brotz scale 69.54 and 84.6% (p ≤ 0.001), patients with high risk of capsule retention offered a patency capsule 4.2 and 73% (p ≤ 0.001), respectively. Conclusion: This study highlights and critically discusses technical and organizational issues that should be considered in defining more realistic PM thresholds, aiming to improve SBCE quality.
publishDate 2023
dc.date.none.fl_str_mv 2023-06-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S2341-45452023000300057
url http://scielo.pt/scielo.php?script=sci_arttext&pid=S2341-45452023000300057
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S2341-45452023000300057
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Portuguesa de Gastrenterologia
publisher.none.fl_str_mv Sociedade Portuguesa de Gastrenterologia
dc.source.none.fl_str_mv GE-Portuguese Journal of Gastroenterology v.30 n.3 2023
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799137415325024256