Precision of wearable heart rate to predict oxygen uptake in endurance vs. sprint-trained runners

Detalhes bibliográficos
Autor(a) principal: Garrido, Nuno Domingos
Data de Publicação: 2022
Outros Autores: Aidar, Felipe José, Vilaça-Alves, José, Oliveira, Diogo Roberto, Szabo, Paul, Reis, Victor Machado
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://doi.org/10.6063/motricidade.27172
Resumo: The present study aimed to assess the precision of oxygen uptake with heart rate regression during treadmill running in highly trained runners. Twenty national and international level male runners were divided into two equal groups. Group A was formed of 10 sprinters (31.5± 4.7 years, height 1.74± 0.04 m and mass 61.8± 5.2 kg), and group B comprised 10 endurance runners (25.7± 4.5 years, height 1.77± 0.08 m and mass 71.2± 5.8 kg). Each participant performed six min bouts at a constant velocity on a level treadmill, with each bout at an increased running velocity. The starting velocity was 3.33 m·s-1, with a 0.56 m·s-1 increase in each subsequent bout. VO2 and HR were measured during all runs. Mean peak VO2 and mean peak HR for Group A were, respectively, 71.7± 7.0 mL·kg-1·min-1 and 179.8± 12.7 beats·min-1, while for Group B were 67.3± 4.9 mL·kg-1·min-1 and 198.2± 9.8 beats·min-1. The linearity of the regressions between VO2 and HR in both groups was very high (R2= 0.97 and R2 =0.76) with small standard errors of regression. Despite a stronger correlation in endurance-trained athletes, the results of the present study indicate that it is possible to use HR as an indicator of exercise intensity in individuals trained in both speed and longer distances.
id RCAP_6743c02428a31d4b6f211521e2320d26
oai_identifier_str oai:ojs.revistas.rcaap.pt:article/27172
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Precision of wearable heart rate to predict oxygen uptake in endurance vs. sprint-trained runnersOriginal ArticleThe present study aimed to assess the precision of oxygen uptake with heart rate regression during treadmill running in highly trained runners. Twenty national and international level male runners were divided into two equal groups. Group A was formed of 10 sprinters (31.5± 4.7 years, height 1.74± 0.04 m and mass 61.8± 5.2 kg), and group B comprised 10 endurance runners (25.7± 4.5 years, height 1.77± 0.08 m and mass 71.2± 5.8 kg). Each participant performed six min bouts at a constant velocity on a level treadmill, with each bout at an increased running velocity. The starting velocity was 3.33 m·s-1, with a 0.56 m·s-1 increase in each subsequent bout. VO2 and HR were measured during all runs. Mean peak VO2 and mean peak HR for Group A were, respectively, 71.7± 7.0 mL·kg-1·min-1 and 179.8± 12.7 beats·min-1, while for Group B were 67.3± 4.9 mL·kg-1·min-1 and 198.2± 9.8 beats·min-1. The linearity of the regressions between VO2 and HR in both groups was very high (R2= 0.97 and R2 =0.76) with small standard errors of regression. Despite a stronger correlation in endurance-trained athletes, the results of the present study indicate that it is possible to use HR as an indicator of exercise intensity in individuals trained in both speed and longer distances.Edições Sílabas Didáticas2022-06-30info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://doi.org/10.6063/motricidade.27172eng2182-29721646-107XGarrido, Nuno DomingosAidar, Felipe JoséVilaça-Alves, JoséOliveira, Diogo RobertoSzabo, PaulReis, Victor Machadoinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-12-08T13:45:15Zoai:ojs.revistas.rcaap.pt:article/27172Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:30:18.038533Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Precision of wearable heart rate to predict oxygen uptake in endurance vs. sprint-trained runners
title Precision of wearable heart rate to predict oxygen uptake in endurance vs. sprint-trained runners
spellingShingle Precision of wearable heart rate to predict oxygen uptake in endurance vs. sprint-trained runners
Garrido, Nuno Domingos
Original Article
title_short Precision of wearable heart rate to predict oxygen uptake in endurance vs. sprint-trained runners
title_full Precision of wearable heart rate to predict oxygen uptake in endurance vs. sprint-trained runners
title_fullStr Precision of wearable heart rate to predict oxygen uptake in endurance vs. sprint-trained runners
title_full_unstemmed Precision of wearable heart rate to predict oxygen uptake in endurance vs. sprint-trained runners
title_sort Precision of wearable heart rate to predict oxygen uptake in endurance vs. sprint-trained runners
author Garrido, Nuno Domingos
author_facet Garrido, Nuno Domingos
Aidar, Felipe José
Vilaça-Alves, José
Oliveira, Diogo Roberto
Szabo, Paul
Reis, Victor Machado
author_role author
author2 Aidar, Felipe José
Vilaça-Alves, José
Oliveira, Diogo Roberto
Szabo, Paul
Reis, Victor Machado
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Garrido, Nuno Domingos
Aidar, Felipe José
Vilaça-Alves, José
Oliveira, Diogo Roberto
Szabo, Paul
Reis, Victor Machado
dc.subject.por.fl_str_mv Original Article
topic Original Article
description The present study aimed to assess the precision of oxygen uptake with heart rate regression during treadmill running in highly trained runners. Twenty national and international level male runners were divided into two equal groups. Group A was formed of 10 sprinters (31.5± 4.7 years, height 1.74± 0.04 m and mass 61.8± 5.2 kg), and group B comprised 10 endurance runners (25.7± 4.5 years, height 1.77± 0.08 m and mass 71.2± 5.8 kg). Each participant performed six min bouts at a constant velocity on a level treadmill, with each bout at an increased running velocity. The starting velocity was 3.33 m·s-1, with a 0.56 m·s-1 increase in each subsequent bout. VO2 and HR were measured during all runs. Mean peak VO2 and mean peak HR for Group A were, respectively, 71.7± 7.0 mL·kg-1·min-1 and 179.8± 12.7 beats·min-1, while for Group B were 67.3± 4.9 mL·kg-1·min-1 and 198.2± 9.8 beats·min-1. The linearity of the regressions between VO2 and HR in both groups was very high (R2= 0.97 and R2 =0.76) with small standard errors of regression. Despite a stronger correlation in endurance-trained athletes, the results of the present study indicate that it is possible to use HR as an indicator of exercise intensity in individuals trained in both speed and longer distances.
publishDate 2022
dc.date.none.fl_str_mv 2022-06-30
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.6063/motricidade.27172
url https://doi.org/10.6063/motricidade.27172
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 2182-2972
1646-107X
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Edições Sílabas Didáticas
publisher.none.fl_str_mv Edições Sílabas Didáticas
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130170125189120