Compliance of indoor air quality during sleep with legislation and guidelines: a case study of Lisbon dwellings
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.21/11740 |
Resumo: | E2Sleep Project 711030-IPL/2017/E2SLEEP/ESTeSL. |
id |
RCAP_67669597cf54a541dafb44bc979bcd21 |
---|---|
oai_identifier_str |
oai:repositorio.ipl.pt:10400.21/11740 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Compliance of indoor air quality during sleep with legislation and guidelines: a case study of Lisbon dwellingsOccupational healthOccupational exposureIndoor airAir qualitySleepParticulate matterBedroomVentilationE2Sleep Project 711030IPL/2017/E2SLEEP/ESTeSL.PortugalE2Sleep Project 711030-IPL/2017/E2SLEEP/ESTeSL.This study aimed to provide a comprehensive characterization of the indoor air quality during the sleeping period of 10 couples at Lisbon dwellings, using a multi-pollutant approach, and to understand how the compliance with legislation and guidelines was to assure good indoor air quality. The assessment of indoor air quality was conducted in the cold season using real-time monitors during the sleeping period for comfort parameters (temperature and relative humidity) and air pollutants (carbon dioxide - CO2, carbon monoxide - CO, formaldehyde - CH2O, total volatile organic compounds - VOCs, and particulate matter - PM2.5 and PM10), together with an active sampling of bioaerosols (fungi and bacteria) before and after the sleeping period. Lower compliance (less than 50% of the cases) with the Portuguese legislation was found for temperature, CO2 (3440 ± 1610 mg m-3), VOCs (1.79 ± 0.99 mg m-3), and both bioaerosol types. In 70% of the cases, PM2.5 (15.3 ± 9.1 μg m-3) exceeded the WHO guideline of 10 μg m-3. All bedrooms presented air change rates above the recommended minimum value of 0.7 h-1, highlighting that good indoor air quality during sleep is not guaranteed.ElsevierRCIPLCanha, NunoAlves, Ana CarolinaMarta, Catarina SimãoLage, JoanaBelo, JoanaFaria, TiagoCabo-Verde, SandraViegas, CarlaAlves, CéliaAlmeida, Susana Marta2020-05-27T19:08:45Z2020-042020-04-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/11740engCanha N, Alves AC, Marta CS, Lage J, Belo J, Viegas C, et al. Compliance of indoor air quality during sleep with legislation and guidelines: a case study of Lisbon dwellings. Environ Pollut. 2020;264:114619.10.1016/j.envpol.2020.114619info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-03T10:03:19Zoai:repositorio.ipl.pt:10400.21/11740Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:19:56.344178Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Compliance of indoor air quality during sleep with legislation and guidelines: a case study of Lisbon dwellings |
title |
Compliance of indoor air quality during sleep with legislation and guidelines: a case study of Lisbon dwellings |
spellingShingle |
Compliance of indoor air quality during sleep with legislation and guidelines: a case study of Lisbon dwellings Canha, Nuno Occupational health Occupational exposure Indoor air Air quality Sleep Particulate matter Bedroom Ventilation E2Sleep Project 711030 IPL/2017/E2SLEEP/ESTeSL. Portugal |
title_short |
Compliance of indoor air quality during sleep with legislation and guidelines: a case study of Lisbon dwellings |
title_full |
Compliance of indoor air quality during sleep with legislation and guidelines: a case study of Lisbon dwellings |
title_fullStr |
Compliance of indoor air quality during sleep with legislation and guidelines: a case study of Lisbon dwellings |
title_full_unstemmed |
Compliance of indoor air quality during sleep with legislation and guidelines: a case study of Lisbon dwellings |
title_sort |
Compliance of indoor air quality during sleep with legislation and guidelines: a case study of Lisbon dwellings |
author |
Canha, Nuno |
author_facet |
Canha, Nuno Alves, Ana Carolina Marta, Catarina Simão Lage, Joana Belo, Joana Faria, Tiago Cabo-Verde, Sandra Viegas, Carla Alves, Célia Almeida, Susana Marta |
author_role |
author |
author2 |
Alves, Ana Carolina Marta, Catarina Simão Lage, Joana Belo, Joana Faria, Tiago Cabo-Verde, Sandra Viegas, Carla Alves, Célia Almeida, Susana Marta |
author2_role |
author author author author author author author author author |
dc.contributor.none.fl_str_mv |
RCIPL |
dc.contributor.author.fl_str_mv |
Canha, Nuno Alves, Ana Carolina Marta, Catarina Simão Lage, Joana Belo, Joana Faria, Tiago Cabo-Verde, Sandra Viegas, Carla Alves, Célia Almeida, Susana Marta |
dc.subject.por.fl_str_mv |
Occupational health Occupational exposure Indoor air Air quality Sleep Particulate matter Bedroom Ventilation E2Sleep Project 711030 IPL/2017/E2SLEEP/ESTeSL. Portugal |
topic |
Occupational health Occupational exposure Indoor air Air quality Sleep Particulate matter Bedroom Ventilation E2Sleep Project 711030 IPL/2017/E2SLEEP/ESTeSL. Portugal |
description |
E2Sleep Project 711030-IPL/2017/E2SLEEP/ESTeSL. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-05-27T19:08:45Z 2020-04 2020-04-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.21/11740 |
url |
http://hdl.handle.net/10400.21/11740 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Canha N, Alves AC, Marta CS, Lage J, Belo J, Viegas C, et al. Compliance of indoor air quality during sleep with legislation and guidelines: a case study of Lisbon dwellings. Environ Pollut. 2020;264:114619. 10.1016/j.envpol.2020.114619 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133467513978880 |