Patients with Large Neck Diameter Have a Higher Risk of Type IA Endoleaks and Aneurysm Rupture after Standard Endovascular Aneurysm Repair

Detalhes bibliográficos
Autor(a) principal: Oliveira, N
Data de Publicação: 2019
Outros Autores: Bastos Gonçalves, F, Ultee, K, Pinto, JP, Rijn, MJ, Raa, S, Mwipatayi, P, Böckler, D, Hoeks, S, Verhagen, H
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.17/3998
Resumo: Objective: Standard endovascular aneurysm repair (EVAR) is the most common treatment of abdominal aortic aneurysms (AAAs). EVAR has been increasingly used in patients with hostile neck features. This study investigated the outcomes of EVAR in patients with neck diameters ≥30 mm in the prospectively maintained Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE). Methods: This is a retrospective study comparing patients with neck diameters ≥30 mm with patients with neck diameters <30 mm. The primary end point was type IA endoleak (EL1A). Secondary end points included secondary interventions to correct EL1A, aneurysm rupture, and survival. Results: This study included 1257 patients (mean age, 73.1 years; 89.4% male) observed for a median 4.0 years (interquartile range, 2.7-4.8 years). A total of 97 (7.7%) patients had infrarenal neck diameters ≥30 mm and were compared with the remaining 1160 (92.3%) with neck diameters <30 mm. At baseline, there were no differences between groups regarding demographics and comorbidities other than cardiac disease, which was more frequent in the ≥30-mm neck diameter group (P = .037). There were no significant differences between the groups regarding neck length, angulation, thrombus, or calcification. Mean preoperative AAA diameter was 64.6 ± 11.3 mm in the ≥30-mm neck diameter group and 60.0 ± 11.6 mm in the <30-mm neck diameter group (P < .001). Stent graft oversizing was significantly less in the ≥30-mm neck diameter group (12.2% ± 8.9% vs 22.1% ± 11.9%; P <. 001). Five patients (5.2%) in the ≥30-mm neck diameter group and 30 (2.6%) with neck diameters <30 mm developed EL1A, yielding a 4-year freedom from EL1A of 92.4% vs 96.6%, respectively (P = .09). Oversizing was 21.8% ± 13.0% for patients developing EL1A and 21.3% ± 12.4% for the remaining cohort (P = .99). In adjusting for neck length, AAA diameter, and device oversizing, patients with neck diameter ≥30 mm were at greater risk for development of EL1A (hazard ratio, 3.0; 95% confidence interval, 1.0-9.3; P = .05). Secondary interventions due to EL1A did not differ between groups (P = .36). AAA rupture occurred in three patients with neck diameter ≥30 mm (3.1%) and in eight patients with neck diameter <30 mm (0.7%; hazard ratio, 5.1; 95% confidence interval, 1.4-19.2; P = .016); two cases were EL1A related in each group. At 4 years, overall survival was 61.6% for the ≥30-mm neck diameter group and 75.2% for the <30-mm neck diameter group (P = .009), which remained significant on correcting for sex and AAA diameter (P = .016). Conclusions: In this study, patients with infrarenal neck diameter ≥30 mm had a threefold increased risk of EL1A and fivefold risk of aneurysm rupture after EVAR as well as worse overall survival. This may influence the choice of AAA repair and underlines the need for regular computed tomography-based imaging surveillance in this subset of patients. Furthermore, these results can serve as standards with which new, possibly improved technology, such as EndoAnchors (Medtronic, Santa Rosa, Calif), can be compared.
id RCAP_693c79bd1fc3223e7c412020ae6c53a5
oai_identifier_str oai:repositorio.chlc.min-saude.pt:10400.17/3998
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Patients with Large Neck Diameter Have a Higher Risk of Type IA Endoleaks and Aneurysm Rupture after Standard Endovascular Aneurysm RepairHSM CIR VASCAgedFemaleMaleHumansAged, 80 and overAortic Aneurysm / complicationsAortic Aneurysm / diagnostic imagingAortic Aneurysm / mortalityAortic Aneurysm / surgeryAortic Rupture / diagnostic imagingAortic Rupture / etiologyAortic Rupture / mortalityBlood Vessel ProsthesisBlood Vessel Prosthesis Implantation / adverse effects*Blood Vessel Prosthesis Implantation / instrumentationBlood Vessel Prosthesis Implantation / mortalityEndoleak / diagnostic imagingEndoleak / etiologyEndoleak / mortalityEndovascular Procedures / adverse effects*Endovascular Procedures / instrumentationEndovascular Procedures / mortalityProduct Surveillance, PostmarketingProsthesis DesignStentsRegistriesRisk FactorsRisk AssessmentRetrospective StudiesTime FactorsTreatment OutcomeObjective: Standard endovascular aneurysm repair (EVAR) is the most common treatment of abdominal aortic aneurysms (AAAs). EVAR has been increasingly used in patients with hostile neck features. This study investigated the outcomes of EVAR in patients with neck diameters ≥30 mm in the prospectively maintained Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE). Methods: This is a retrospective study comparing patients with neck diameters ≥30 mm with patients with neck diameters <30 mm. The primary end point was type IA endoleak (EL1A). Secondary end points included secondary interventions to correct EL1A, aneurysm rupture, and survival. Results: This study included 1257 patients (mean age, 73.1 years; 89.4% male) observed for a median 4.0 years (interquartile range, 2.7-4.8 years). A total of 97 (7.7%) patients had infrarenal neck diameters ≥30 mm and were compared with the remaining 1160 (92.3%) with neck diameters <30 mm. At baseline, there were no differences between groups regarding demographics and comorbidities other than cardiac disease, which was more frequent in the ≥30-mm neck diameter group (P = .037). There were no significant differences between the groups regarding neck length, angulation, thrombus, or calcification. Mean preoperative AAA diameter was 64.6 ± 11.3 mm in the ≥30-mm neck diameter group and 60.0 ± 11.6 mm in the <30-mm neck diameter group (P < .001). Stent graft oversizing was significantly less in the ≥30-mm neck diameter group (12.2% ± 8.9% vs 22.1% ± 11.9%; P <. 001). Five patients (5.2%) in the ≥30-mm neck diameter group and 30 (2.6%) with neck diameters <30 mm developed EL1A, yielding a 4-year freedom from EL1A of 92.4% vs 96.6%, respectively (P = .09). Oversizing was 21.8% ± 13.0% for patients developing EL1A and 21.3% ± 12.4% for the remaining cohort (P = .99). In adjusting for neck length, AAA diameter, and device oversizing, patients with neck diameter ≥30 mm were at greater risk for development of EL1A (hazard ratio, 3.0; 95% confidence interval, 1.0-9.3; P = .05). Secondary interventions due to EL1A did not differ between groups (P = .36). AAA rupture occurred in three patients with neck diameter ≥30 mm (3.1%) and in eight patients with neck diameter <30 mm (0.7%; hazard ratio, 5.1; 95% confidence interval, 1.4-19.2; P = .016); two cases were EL1A related in each group. At 4 years, overall survival was 61.6% for the ≥30-mm neck diameter group and 75.2% for the <30-mm neck diameter group (P = .009), which remained significant on correcting for sex and AAA diameter (P = .016). Conclusions: In this study, patients with infrarenal neck diameter ≥30 mm had a threefold increased risk of EL1A and fivefold risk of aneurysm rupture after EVAR as well as worse overall survival. This may influence the choice of AAA repair and underlines the need for regular computed tomography-based imaging surveillance in this subset of patients. Furthermore, these results can serve as standards with which new, possibly improved technology, such as EndoAnchors (Medtronic, Santa Rosa, Calif), can be compared.ElsevierRepositório do Centro Hospitalar Universitário de Lisboa Central, EPEOliveira, NBastos Gonçalves, FUltee, KPinto, JPRijn, MJRaa, SMwipatayi, PBöckler, DHoeks, SVerhagen, H2022-03-10T16:07:18Z20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.17/3998engJ Vasc Surg. 2019 Mar;69(3):783-791.10.1016/j.jvs.2018.07.021.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-10T09:44:53Zoai:repositorio.chlc.min-saude.pt:10400.17/3998Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:21:18.326896Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Patients with Large Neck Diameter Have a Higher Risk of Type IA Endoleaks and Aneurysm Rupture after Standard Endovascular Aneurysm Repair
title Patients with Large Neck Diameter Have a Higher Risk of Type IA Endoleaks and Aneurysm Rupture after Standard Endovascular Aneurysm Repair
spellingShingle Patients with Large Neck Diameter Have a Higher Risk of Type IA Endoleaks and Aneurysm Rupture after Standard Endovascular Aneurysm Repair
Oliveira, N
HSM CIR VASC
Aged
Female
Male
Humans
Aged, 80 and over
Aortic Aneurysm / complications
Aortic Aneurysm / diagnostic imaging
Aortic Aneurysm / mortality
Aortic Aneurysm / surgery
Aortic Rupture / diagnostic imaging
Aortic Rupture / etiology
Aortic Rupture / mortality
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation / adverse effects*
Blood Vessel Prosthesis Implantation / instrumentation
Blood Vessel Prosthesis Implantation / mortality
Endoleak / diagnostic imaging
Endoleak / etiology
Endoleak / mortality
Endovascular Procedures / adverse effects*
Endovascular Procedures / instrumentation
Endovascular Procedures / mortality
Product Surveillance, Postmarketing
Prosthesis Design
Stents
Registries
Risk Factors
Risk Assessment
Retrospective Studies
Time Factors
Treatment Outcome
title_short Patients with Large Neck Diameter Have a Higher Risk of Type IA Endoleaks and Aneurysm Rupture after Standard Endovascular Aneurysm Repair
title_full Patients with Large Neck Diameter Have a Higher Risk of Type IA Endoleaks and Aneurysm Rupture after Standard Endovascular Aneurysm Repair
title_fullStr Patients with Large Neck Diameter Have a Higher Risk of Type IA Endoleaks and Aneurysm Rupture after Standard Endovascular Aneurysm Repair
title_full_unstemmed Patients with Large Neck Diameter Have a Higher Risk of Type IA Endoleaks and Aneurysm Rupture after Standard Endovascular Aneurysm Repair
title_sort Patients with Large Neck Diameter Have a Higher Risk of Type IA Endoleaks and Aneurysm Rupture after Standard Endovascular Aneurysm Repair
author Oliveira, N
author_facet Oliveira, N
Bastos Gonçalves, F
Ultee, K
Pinto, JP
Rijn, MJ
Raa, S
Mwipatayi, P
Böckler, D
Hoeks, S
Verhagen, H
author_role author
author2 Bastos Gonçalves, F
Ultee, K
Pinto, JP
Rijn, MJ
Raa, S
Mwipatayi, P
Böckler, D
Hoeks, S
Verhagen, H
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Repositório do Centro Hospitalar Universitário de Lisboa Central, EPE
dc.contributor.author.fl_str_mv Oliveira, N
Bastos Gonçalves, F
Ultee, K
Pinto, JP
Rijn, MJ
Raa, S
Mwipatayi, P
Böckler, D
Hoeks, S
Verhagen, H
dc.subject.por.fl_str_mv HSM CIR VASC
Aged
Female
Male
Humans
Aged, 80 and over
Aortic Aneurysm / complications
Aortic Aneurysm / diagnostic imaging
Aortic Aneurysm / mortality
Aortic Aneurysm / surgery
Aortic Rupture / diagnostic imaging
Aortic Rupture / etiology
Aortic Rupture / mortality
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation / adverse effects*
Blood Vessel Prosthesis Implantation / instrumentation
Blood Vessel Prosthesis Implantation / mortality
Endoleak / diagnostic imaging
Endoleak / etiology
Endoleak / mortality
Endovascular Procedures / adverse effects*
Endovascular Procedures / instrumentation
Endovascular Procedures / mortality
Product Surveillance, Postmarketing
Prosthesis Design
Stents
Registries
Risk Factors
Risk Assessment
Retrospective Studies
Time Factors
Treatment Outcome
topic HSM CIR VASC
Aged
Female
Male
Humans
Aged, 80 and over
Aortic Aneurysm / complications
Aortic Aneurysm / diagnostic imaging
Aortic Aneurysm / mortality
Aortic Aneurysm / surgery
Aortic Rupture / diagnostic imaging
Aortic Rupture / etiology
Aortic Rupture / mortality
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation / adverse effects*
Blood Vessel Prosthesis Implantation / instrumentation
Blood Vessel Prosthesis Implantation / mortality
Endoleak / diagnostic imaging
Endoleak / etiology
Endoleak / mortality
Endovascular Procedures / adverse effects*
Endovascular Procedures / instrumentation
Endovascular Procedures / mortality
Product Surveillance, Postmarketing
Prosthesis Design
Stents
Registries
Risk Factors
Risk Assessment
Retrospective Studies
Time Factors
Treatment Outcome
description Objective: Standard endovascular aneurysm repair (EVAR) is the most common treatment of abdominal aortic aneurysms (AAAs). EVAR has been increasingly used in patients with hostile neck features. This study investigated the outcomes of EVAR in patients with neck diameters ≥30 mm in the prospectively maintained Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE). Methods: This is a retrospective study comparing patients with neck diameters ≥30 mm with patients with neck diameters <30 mm. The primary end point was type IA endoleak (EL1A). Secondary end points included secondary interventions to correct EL1A, aneurysm rupture, and survival. Results: This study included 1257 patients (mean age, 73.1 years; 89.4% male) observed for a median 4.0 years (interquartile range, 2.7-4.8 years). A total of 97 (7.7%) patients had infrarenal neck diameters ≥30 mm and were compared with the remaining 1160 (92.3%) with neck diameters <30 mm. At baseline, there were no differences between groups regarding demographics and comorbidities other than cardiac disease, which was more frequent in the ≥30-mm neck diameter group (P = .037). There were no significant differences between the groups regarding neck length, angulation, thrombus, or calcification. Mean preoperative AAA diameter was 64.6 ± 11.3 mm in the ≥30-mm neck diameter group and 60.0 ± 11.6 mm in the <30-mm neck diameter group (P < .001). Stent graft oversizing was significantly less in the ≥30-mm neck diameter group (12.2% ± 8.9% vs 22.1% ± 11.9%; P <. 001). Five patients (5.2%) in the ≥30-mm neck diameter group and 30 (2.6%) with neck diameters <30 mm developed EL1A, yielding a 4-year freedom from EL1A of 92.4% vs 96.6%, respectively (P = .09). Oversizing was 21.8% ± 13.0% for patients developing EL1A and 21.3% ± 12.4% for the remaining cohort (P = .99). In adjusting for neck length, AAA diameter, and device oversizing, patients with neck diameter ≥30 mm were at greater risk for development of EL1A (hazard ratio, 3.0; 95% confidence interval, 1.0-9.3; P = .05). Secondary interventions due to EL1A did not differ between groups (P = .36). AAA rupture occurred in three patients with neck diameter ≥30 mm (3.1%) and in eight patients with neck diameter <30 mm (0.7%; hazard ratio, 5.1; 95% confidence interval, 1.4-19.2; P = .016); two cases were EL1A related in each group. At 4 years, overall survival was 61.6% for the ≥30-mm neck diameter group and 75.2% for the <30-mm neck diameter group (P = .009), which remained significant on correcting for sex and AAA diameter (P = .016). Conclusions: In this study, patients with infrarenal neck diameter ≥30 mm had a threefold increased risk of EL1A and fivefold risk of aneurysm rupture after EVAR as well as worse overall survival. This may influence the choice of AAA repair and underlines the need for regular computed tomography-based imaging surveillance in this subset of patients. Furthermore, these results can serve as standards with which new, possibly improved technology, such as EndoAnchors (Medtronic, Santa Rosa, Calif), can be compared.
publishDate 2019
dc.date.none.fl_str_mv 2019
2019-01-01T00:00:00Z
2022-03-10T16:07:18Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.17/3998
url http://hdl.handle.net/10400.17/3998
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv J Vasc Surg. 2019 Mar;69(3):783-791.
10.1016/j.jvs.2018.07.021.
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131308523257856