Anterior Chamber Flare as an Objective and Quantitative Noninvasive Method for Oculopathy in Transthyretin V30M Amyloidosis Patients

Detalhes bibliográficos
Autor(a) principal: Beirão, J.
Data de Publicação: 2018
Outros Autores: Miranda, V., Pinheiro-Torres, B., Coelho, J., Menéres, M., Menéres, P.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.16/2301
Resumo: Purpose. Assess the aqueous humor flare in transthyretin V30M amyloidosis patients (ATTRV30M). Materials and Methods. This is a retrospective, cross-sectional, noninterventional comparative study including 28 ATTRV30M patients with a unilateral scalloped iris. For comparative analysis, the fellow eye, the nonscalloped iris eye, from each patient was used as control. All patients underwent aqueous humor flare meter and intraocular pressure (IOP) measurements. Results. Mean aqueous humor flare was significantly higher in the eyes with the scalloped iris than the control group with the nonscalloped iris (14.1 ± 2.2 versus 6.5 ± 0.9 pc/ms, respectively). No significant differences in IOP were found in the scalloped iris eyes than those in the nonscalloped iris control group (17.1 ± 0.8 versus 16.8 ± 0.7 mmHg, respectively). No significant correlation was not found between the flare and the IOP value within groups. Conclusions. In this study, aqueous humor flare values in the scalloped iris eyes may be a valid marker for controlling the stage of the oculopathy in ATTRV30M patients.
id RCAP_6b5c0f020b59c308e76b9602c8611843
oai_identifier_str oai:repositorio.chporto.pt:10400.16/2301
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Anterior Chamber Flare as an Objective and Quantitative Noninvasive Method for Oculopathy in Transthyretin V30M Amyloidosis PatientsPurpose. Assess the aqueous humor flare in transthyretin V30M amyloidosis patients (ATTRV30M). Materials and Methods. This is a retrospective, cross-sectional, noninterventional comparative study including 28 ATTRV30M patients with a unilateral scalloped iris. For comparative analysis, the fellow eye, the nonscalloped iris eye, from each patient was used as control. All patients underwent aqueous humor flare meter and intraocular pressure (IOP) measurements. Results. Mean aqueous humor flare was significantly higher in the eyes with the scalloped iris than the control group with the nonscalloped iris (14.1 ± 2.2 versus 6.5 ± 0.9 pc/ms, respectively). No significant differences in IOP were found in the scalloped iris eyes than those in the nonscalloped iris control group (17.1 ± 0.8 versus 16.8 ± 0.7 mmHg, respectively). No significant correlation was not found between the flare and the IOP value within groups. Conclusions. In this study, aqueous humor flare values in the scalloped iris eyes may be a valid marker for controlling the stage of the oculopathy in ATTRV30M patients.Hindawi Publishing CorporationRepositório Científico do Centro Hospitalar Universitário de Santo AntónioBeirão, J.Miranda, V.Pinheiro-Torres, B.Coelho, J.Menéres, M.Menéres, P.2019-11-19T14:44:22Z2018-09-202018-09-20T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.16/2301engJ Ophthalmol. 2018 Sep 20;2018:37275432090-004X10.1155/2018/3727543info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-10-20T11:00:07Zoai:repositorio.chporto.pt:10400.16/2301Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:38:31.062417Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Anterior Chamber Flare as an Objective and Quantitative Noninvasive Method for Oculopathy in Transthyretin V30M Amyloidosis Patients
title Anterior Chamber Flare as an Objective and Quantitative Noninvasive Method for Oculopathy in Transthyretin V30M Amyloidosis Patients
spellingShingle Anterior Chamber Flare as an Objective and Quantitative Noninvasive Method for Oculopathy in Transthyretin V30M Amyloidosis Patients
Beirão, J.
title_short Anterior Chamber Flare as an Objective and Quantitative Noninvasive Method for Oculopathy in Transthyretin V30M Amyloidosis Patients
title_full Anterior Chamber Flare as an Objective and Quantitative Noninvasive Method for Oculopathy in Transthyretin V30M Amyloidosis Patients
title_fullStr Anterior Chamber Flare as an Objective and Quantitative Noninvasive Method for Oculopathy in Transthyretin V30M Amyloidosis Patients
title_full_unstemmed Anterior Chamber Flare as an Objective and Quantitative Noninvasive Method for Oculopathy in Transthyretin V30M Amyloidosis Patients
title_sort Anterior Chamber Flare as an Objective and Quantitative Noninvasive Method for Oculopathy in Transthyretin V30M Amyloidosis Patients
author Beirão, J.
author_facet Beirão, J.
Miranda, V.
Pinheiro-Torres, B.
Coelho, J.
Menéres, M.
Menéres, P.
author_role author
author2 Miranda, V.
Pinheiro-Torres, B.
Coelho, J.
Menéres, M.
Menéres, P.
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Repositório Científico do Centro Hospitalar Universitário de Santo António
dc.contributor.author.fl_str_mv Beirão, J.
Miranda, V.
Pinheiro-Torres, B.
Coelho, J.
Menéres, M.
Menéres, P.
description Purpose. Assess the aqueous humor flare in transthyretin V30M amyloidosis patients (ATTRV30M). Materials and Methods. This is a retrospective, cross-sectional, noninterventional comparative study including 28 ATTRV30M patients with a unilateral scalloped iris. For comparative analysis, the fellow eye, the nonscalloped iris eye, from each patient was used as control. All patients underwent aqueous humor flare meter and intraocular pressure (IOP) measurements. Results. Mean aqueous humor flare was significantly higher in the eyes with the scalloped iris than the control group with the nonscalloped iris (14.1 ± 2.2 versus 6.5 ± 0.9 pc/ms, respectively). No significant differences in IOP were found in the scalloped iris eyes than those in the nonscalloped iris control group (17.1 ± 0.8 versus 16.8 ± 0.7 mmHg, respectively). No significant correlation was not found between the flare and the IOP value within groups. Conclusions. In this study, aqueous humor flare values in the scalloped iris eyes may be a valid marker for controlling the stage of the oculopathy in ATTRV30M patients.
publishDate 2018
dc.date.none.fl_str_mv 2018-09-20
2018-09-20T00:00:00Z
2019-11-19T14:44:22Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.16/2301
url http://hdl.handle.net/10400.16/2301
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv J Ophthalmol. 2018 Sep 20;2018:3727543
2090-004X
10.1155/2018/3727543
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Hindawi Publishing Corporation
publisher.none.fl_str_mv Hindawi Publishing Corporation
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133646346518528