Benchtop SS-OCT – layout and performance evaluation
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://doi.org/10.34629/ipl.isel.i-ETC.22 |
Resumo: | Abstract1— Optical coherence tomography (OCT) is a non-invasive biomedical imaging technique that provides high speed and high resolution three dimensional and cross sectional images of biological samples, in vivo and in situ. OCT applications targeting small animals is believed to bring developments in medical techniques, instruments, diagnosis and therapies for a number of human diseases as always have been the case of animal experimentation. With the swept source OCT (SS-OCT) system presented in this work, we were able to achieve performance parameters that meet the requirements to image the retina of small animals. Performance characteristics include 105 dB for system sensitivity, a roll-off below 1 dB/mm over 3 mm depth and an axial resolution of 8 μm. We describe the layout and acquisition/processing solutions towards fast imaging of in vivo samples. |
id |
RCAP_6d7f6ec1e97b70d06c957ae22e82b85d |
---|---|
oai_identifier_str |
oai:i-ETC.journals.isel.pt:article/22 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Benchtop SS-OCT – layout and performance evaluationElectronics;OptoelectronicsSwept Source OCT, Imaging, Instrumentation Abstract1— Optical coherence tomography (OCT) is a non-invasive biomedical imaging technique that provides high speed and high resolution three dimensional and cross sectional images of biological samples, in vivo and in situ. OCT applications targeting small animals is believed to bring developments in medical techniques, instruments, diagnosis and therapies for a number of human diseases as always have been the case of animal experimentation. With the swept source OCT (SS-OCT) system presented in this work, we were able to achieve performance parameters that meet the requirements to image the retina of small animals. Performance characteristics include 105 dB for system sensitivity, a roll-off below 1 dB/mm over 3 mm depth and an axial resolution of 8 μm. We describe the layout and acquisition/processing solutions towards fast imaging of in vivo samples.ISEL - High Institute of Engineering of Lisbon2017-10-26T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://doi.org/10.34629/ipl.isel.i-ETC.22oai:i-ETC.journals.isel.pt:article/22i-ETC : ISEL Academic Journal of Electronics Telecommunications and Computers; Vol 3, No 1 (2017): The CETC2016 Issue (A); ID-8i-ETC : ISEL Academic Journal of Electronics Telecommunications and Computers; Vol 3, No 1 (2017): The CETC2016 Issue (A); ID-82182-4010reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://journals.isel.pt/index.php/i-ETC/article/view/22https://doi.org/10.34629/ipl.isel.i-ETC.22http://journals.isel.pt/index.php/i-ETC/article/view/22/35Copyright (c) 2017 Jose Paulo Domingueshttp://creativecommons.org/licenses/by-nc/4.0info:eu-repo/semantics/openAccessDomingues, Jose PauloSilva, Susana F.Bernardes, RuiMorgado, A. M.2022-09-20T15:26:07Zoai:i-ETC.journals.isel.pt:article/22Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:51:12.550258Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Benchtop SS-OCT – layout and performance evaluation |
title |
Benchtop SS-OCT – layout and performance evaluation |
spellingShingle |
Benchtop SS-OCT – layout and performance evaluation Domingues, Jose Paulo Electronics;Optoelectronics Swept Source OCT, Imaging, Instrumentation |
title_short |
Benchtop SS-OCT – layout and performance evaluation |
title_full |
Benchtop SS-OCT – layout and performance evaluation |
title_fullStr |
Benchtop SS-OCT – layout and performance evaluation |
title_full_unstemmed |
Benchtop SS-OCT – layout and performance evaluation |
title_sort |
Benchtop SS-OCT – layout and performance evaluation |
author |
Domingues, Jose Paulo |
author_facet |
Domingues, Jose Paulo Silva, Susana F. Bernardes, Rui Morgado, A. M. |
author_role |
author |
author2 |
Silva, Susana F. Bernardes, Rui Morgado, A. M. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Domingues, Jose Paulo Silva, Susana F. Bernardes, Rui Morgado, A. M. |
dc.subject.por.fl_str_mv |
Electronics;Optoelectronics Swept Source OCT, Imaging, Instrumentation |
topic |
Electronics;Optoelectronics Swept Source OCT, Imaging, Instrumentation |
description |
Abstract1— Optical coherence tomography (OCT) is a non-invasive biomedical imaging technique that provides high speed and high resolution three dimensional and cross sectional images of biological samples, in vivo and in situ. OCT applications targeting small animals is believed to bring developments in medical techniques, instruments, diagnosis and therapies for a number of human diseases as always have been the case of animal experimentation. With the swept source OCT (SS-OCT) system presented in this work, we were able to achieve performance parameters that meet the requirements to image the retina of small animals. Performance characteristics include 105 dB for system sensitivity, a roll-off below 1 dB/mm over 3 mm depth and an axial resolution of 8 μm. We describe the layout and acquisition/processing solutions towards fast imaging of in vivo samples. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-10-26T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://doi.org/10.34629/ipl.isel.i-ETC.22 oai:i-ETC.journals.isel.pt:article/22 |
url |
https://doi.org/10.34629/ipl.isel.i-ETC.22 |
identifier_str_mv |
oai:i-ETC.journals.isel.pt:article/22 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://journals.isel.pt/index.php/i-ETC/article/view/22 https://doi.org/10.34629/ipl.isel.i-ETC.22 http://journals.isel.pt/index.php/i-ETC/article/view/22/35 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2017 Jose Paulo Domingues http://creativecommons.org/licenses/by-nc/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2017 Jose Paulo Domingues http://creativecommons.org/licenses/by-nc/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
ISEL - High Institute of Engineering of Lisbon |
publisher.none.fl_str_mv |
ISEL - High Institute of Engineering of Lisbon |
dc.source.none.fl_str_mv |
i-ETC : ISEL Academic Journal of Electronics Telecommunications and Computers; Vol 3, No 1 (2017): The CETC2016 Issue (A); ID-8 i-ETC : ISEL Academic Journal of Electronics Telecommunications and Computers; Vol 3, No 1 (2017): The CETC2016 Issue (A); ID-8 2182-4010 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799130375512915968 |