Benchtop SS-OCT – layout and performance evaluation

Detalhes bibliográficos
Autor(a) principal: Domingues, Jose Paulo
Data de Publicação: 2017
Outros Autores: Silva, Susana F., Bernardes, Rui, Morgado, A. M.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://doi.org/10.34629/ipl.isel.i-ETC.22
Resumo:  Abstract1— Optical coherence tomography (OCT) is a non-invasive biomedical imaging technique that provides high speed and high resolution three dimensional and cross sectional images of biological samples, in vivo and in situ. OCT applications targeting small animals is believed to bring developments in medical techniques, instruments, diagnosis and therapies for a number of human diseases as always have been the case of animal experimentation. With the swept source OCT (SS-OCT) system presented in this work, we were able to achieve performance parameters that meet the requirements to image the retina of small animals. Performance characteristics include 105 dB for system sensitivity, a roll-off below 1 dB/mm over 3 mm depth and an axial resolution of 8 μm. We describe the layout and acquisition/processing solutions towards fast imaging of in vivo samples.
id RCAP_6d7f6ec1e97b70d06c957ae22e82b85d
oai_identifier_str oai:i-ETC.journals.isel.pt:article/22
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Benchtop SS-OCT – layout and performance evaluationElectronics;OptoelectronicsSwept Source OCT, Imaging, Instrumentation Abstract1— Optical coherence tomography (OCT) is a non-invasive biomedical imaging technique that provides high speed and high resolution three dimensional and cross sectional images of biological samples, in vivo and in situ. OCT applications targeting small animals is believed to bring developments in medical techniques, instruments, diagnosis and therapies for a number of human diseases as always have been the case of animal experimentation. With the swept source OCT (SS-OCT) system presented in this work, we were able to achieve performance parameters that meet the requirements to image the retina of small animals. Performance characteristics include 105 dB for system sensitivity, a roll-off below 1 dB/mm over 3 mm depth and an axial resolution of 8 μm. We describe the layout and acquisition/processing solutions towards fast imaging of in vivo samples.ISEL - High Institute of Engineering of Lisbon2017-10-26T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://doi.org/10.34629/ipl.isel.i-ETC.22oai:i-ETC.journals.isel.pt:article/22i-ETC : ISEL Academic Journal of Electronics Telecommunications and Computers; Vol 3, No 1 (2017): The CETC2016 Issue (A); ID-8i-ETC : ISEL Academic Journal of Electronics Telecommunications and Computers; Vol 3, No 1 (2017): The CETC2016 Issue (A); ID-82182-4010reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://journals.isel.pt/index.php/i-ETC/article/view/22https://doi.org/10.34629/ipl.isel.i-ETC.22http://journals.isel.pt/index.php/i-ETC/article/view/22/35Copyright (c) 2017 Jose Paulo Domingueshttp://creativecommons.org/licenses/by-nc/4.0info:eu-repo/semantics/openAccessDomingues, Jose PauloSilva, Susana F.Bernardes, RuiMorgado, A. M.2022-09-20T15:26:07Zoai:i-ETC.journals.isel.pt:article/22Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:51:12.550258Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Benchtop SS-OCT – layout and performance evaluation
title Benchtop SS-OCT – layout and performance evaluation
spellingShingle Benchtop SS-OCT – layout and performance evaluation
Domingues, Jose Paulo
Electronics;Optoelectronics
Swept Source OCT, Imaging, Instrumentation
title_short Benchtop SS-OCT – layout and performance evaluation
title_full Benchtop SS-OCT – layout and performance evaluation
title_fullStr Benchtop SS-OCT – layout and performance evaluation
title_full_unstemmed Benchtop SS-OCT – layout and performance evaluation
title_sort Benchtop SS-OCT – layout and performance evaluation
author Domingues, Jose Paulo
author_facet Domingues, Jose Paulo
Silva, Susana F.
Bernardes, Rui
Morgado, A. M.
author_role author
author2 Silva, Susana F.
Bernardes, Rui
Morgado, A. M.
author2_role author
author
author
dc.contributor.author.fl_str_mv Domingues, Jose Paulo
Silva, Susana F.
Bernardes, Rui
Morgado, A. M.
dc.subject.por.fl_str_mv Electronics;Optoelectronics
Swept Source OCT, Imaging, Instrumentation
topic Electronics;Optoelectronics
Swept Source OCT, Imaging, Instrumentation
description  Abstract1— Optical coherence tomography (OCT) is a non-invasive biomedical imaging technique that provides high speed and high resolution three dimensional and cross sectional images of biological samples, in vivo and in situ. OCT applications targeting small animals is believed to bring developments in medical techniques, instruments, diagnosis and therapies for a number of human diseases as always have been the case of animal experimentation. With the swept source OCT (SS-OCT) system presented in this work, we were able to achieve performance parameters that meet the requirements to image the retina of small animals. Performance characteristics include 105 dB for system sensitivity, a roll-off below 1 dB/mm over 3 mm depth and an axial resolution of 8 μm. We describe the layout and acquisition/processing solutions towards fast imaging of in vivo samples.
publishDate 2017
dc.date.none.fl_str_mv 2017-10-26T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.34629/ipl.isel.i-ETC.22
oai:i-ETC.journals.isel.pt:article/22
url https://doi.org/10.34629/ipl.isel.i-ETC.22
identifier_str_mv oai:i-ETC.journals.isel.pt:article/22
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv http://journals.isel.pt/index.php/i-ETC/article/view/22
https://doi.org/10.34629/ipl.isel.i-ETC.22
http://journals.isel.pt/index.php/i-ETC/article/view/22/35
dc.rights.driver.fl_str_mv Copyright (c) 2017 Jose Paulo Domingues
http://creativecommons.org/licenses/by-nc/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2017 Jose Paulo Domingues
http://creativecommons.org/licenses/by-nc/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv ISEL - High Institute of Engineering of Lisbon
publisher.none.fl_str_mv ISEL - High Institute of Engineering of Lisbon
dc.source.none.fl_str_mv i-ETC : ISEL Academic Journal of Electronics Telecommunications and Computers; Vol 3, No 1 (2017): The CETC2016 Issue (A); ID-8
i-ETC : ISEL Academic Journal of Electronics Telecommunications and Computers; Vol 3, No 1 (2017): The CETC2016 Issue (A); ID-8
2182-4010
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130375512915968