CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinets
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.6/7586 |
Resumo: | The thermal behaviour of open refrigerated display cabinets depends of ambient air condition variations such as air temperature, relative humidity and velocity magnitude and orientation. The location of air conditioning system discharge grilles, mass flows originated by pressure differences due to openings to surroundings, and air flow perturbation due to consumers’ passage nearby the frontal opening of the display cabinet, among others, affect the re-circulated air curtain behaviour and consequently the equipment’s overall thermal performance. This study presents a three-dimensional (3D) Computational Fluid Dynamics (CFD) modelling of the physical-mathematical phenomena occurring in an open refrigerated display cabinet, and particularly concerns the aerothermodynamics system of recirculated air curtain, under different magnitude values of the ambient air velocity (according to EN-ISO Standard 23953 and doubled one). A parametric study is undertaken for the air flow and heat transfer numerical predictions to determine the open refrigerated display cabinet’s thermal behaviour and of the re-circulated air curtain, taking into account the ambient air velocity’s magnitude. Results from experimental tests following EN-ISO Standard 23953 for climatic class n.er 3 (Tamb = 25 ºC, amb = 60%) are used to characterize the phenomena near inlets, outlets and physical borders. To prescribe boundary conditions as well as to validate numerical predictions of temperature and velocity distributions, the experimental results are applied. |
id |
RCAP_78563aee99883687139ec597c6c82db2 |
---|---|
oai_identifier_str |
oai:ubibliorum.ubi.pt:10400.6/7586 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinetsFluid DynamicsCD-ROMInstructionsDeadlinesConference siteThe thermal behaviour of open refrigerated display cabinets depends of ambient air condition variations such as air temperature, relative humidity and velocity magnitude and orientation. The location of air conditioning system discharge grilles, mass flows originated by pressure differences due to openings to surroundings, and air flow perturbation due to consumers’ passage nearby the frontal opening of the display cabinet, among others, affect the re-circulated air curtain behaviour and consequently the equipment’s overall thermal performance. This study presents a three-dimensional (3D) Computational Fluid Dynamics (CFD) modelling of the physical-mathematical phenomena occurring in an open refrigerated display cabinet, and particularly concerns the aerothermodynamics system of recirculated air curtain, under different magnitude values of the ambient air velocity (according to EN-ISO Standard 23953 and doubled one). A parametric study is undertaken for the air flow and heat transfer numerical predictions to determine the open refrigerated display cabinet’s thermal behaviour and of the re-circulated air curtain, taking into account the ambient air velocity’s magnitude. Results from experimental tests following EN-ISO Standard 23953 for climatic class n.er 3 (Tamb = 25 ºC, amb = 60%) are used to characterize the phenomena near inlets, outlets and physical borders. To prescribe boundary conditions as well as to validate numerical predictions of temperature and velocity distributions, the experimental results are applied.5th European Conference on Computational Fluid Dynamics, ECCOMAS CFD 2010uBibliorumGaspar, Pedro DinisGonçalves, Luís Carlos CarrilhoGe, Xiao2019-11-19T09:45:04Z2010-062010-06-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.6/7586eng978-989-96778-1-4info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-11-27T12:25:39Zoai:ubibliorum.ubi.pt:10400.6/7586Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-11-27T12:25:39Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinets |
title |
CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinets |
spellingShingle |
CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinets Gaspar, Pedro Dinis Fluid Dynamics CD-ROM Instructions Deadlines Conference site |
title_short |
CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinets |
title_full |
CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinets |
title_fullStr |
CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinets |
title_full_unstemmed |
CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinets |
title_sort |
CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinets |
author |
Gaspar, Pedro Dinis |
author_facet |
Gaspar, Pedro Dinis Gonçalves, Luís Carlos Carrilho Ge, Xiao |
author_role |
author |
author2 |
Gonçalves, Luís Carlos Carrilho Ge, Xiao |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
uBibliorum |
dc.contributor.author.fl_str_mv |
Gaspar, Pedro Dinis Gonçalves, Luís Carlos Carrilho Ge, Xiao |
dc.subject.por.fl_str_mv |
Fluid Dynamics CD-ROM Instructions Deadlines Conference site |
topic |
Fluid Dynamics CD-ROM Instructions Deadlines Conference site |
description |
The thermal behaviour of open refrigerated display cabinets depends of ambient air condition variations such as air temperature, relative humidity and velocity magnitude and orientation. The location of air conditioning system discharge grilles, mass flows originated by pressure differences due to openings to surroundings, and air flow perturbation due to consumers’ passage nearby the frontal opening of the display cabinet, among others, affect the re-circulated air curtain behaviour and consequently the equipment’s overall thermal performance. This study presents a three-dimensional (3D) Computational Fluid Dynamics (CFD) modelling of the physical-mathematical phenomena occurring in an open refrigerated display cabinet, and particularly concerns the aerothermodynamics system of recirculated air curtain, under different magnitude values of the ambient air velocity (according to EN-ISO Standard 23953 and doubled one). A parametric study is undertaken for the air flow and heat transfer numerical predictions to determine the open refrigerated display cabinet’s thermal behaviour and of the re-circulated air curtain, taking into account the ambient air velocity’s magnitude. Results from experimental tests following EN-ISO Standard 23953 for climatic class n.er 3 (Tamb = 25 ºC, amb = 60%) are used to characterize the phenomena near inlets, outlets and physical borders. To prescribe boundary conditions as well as to validate numerical predictions of temperature and velocity distributions, the experimental results are applied. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-06 2010-06-01T00:00:00Z 2019-11-19T09:45:04Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.6/7586 |
url |
http://hdl.handle.net/10400.6/7586 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
978-989-96778-1-4 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
5th European Conference on Computational Fluid Dynamics, ECCOMAS CFD 2010 |
publisher.none.fl_str_mv |
5th European Conference on Computational Fluid Dynamics, ECCOMAS CFD 2010 |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
mluisa.alvim@gmail.com |
_version_ |
1817549628005941248 |