Influence of blood contamination on adhesion of bioceramic materials to root dentin

Detalhes bibliográficos
Autor(a) principal: Paulo, Sónia Cristina Rodrigues
Data de Publicação: 2019
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/89615
Resumo: Trabalho Final do Mestrado Integrado em Medicina Dentária apresentado à Faculdade de Medicina
id RCAP_7abf5177ccd0a0bf58eacdee626c0abb
oai_identifier_str oai:estudogeral.uc.pt:10316/89615
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Influence of blood contamination on adhesion of bioceramic materials to root dentinInfluência da contaminação sanguínea na adesão de materiais biocerâmicos à dentina radicularcimentos silicatos de cálcioforça adesiva push outcontaminação sanguíneaProRoot MTABiodentinecalcium silicate-based cementspush out bond strengthblood contaminationProRoot MTABiodentineTrabalho Final do Mestrado Integrado em Medicina Dentária apresentado à Faculdade de MedicinaIntrodução: Este estudo tem como objetivo determinar a força de adesão de 4 cimentos biocerâmicos (ProRoot® MTA, Biodentine™, TotalFill BC RRM™ putty and PulpGuard®) à dentina radicular, com e sem contaminação sanguínea, avaliada por testes de push-out. Materiais e Métodos: Foram recolhidos 120 dentes humanos monorradiculares, seccionados com um comprimento radicular padronizado de 15 mm e os canais preparados até à broca Gates Glidden nº4. As amostras foram divididas em 4 grupos, de acordo com o material utilizado (ProRoot® MTA, Biodentine™, TotalFill BC RRM™ putty e PulpGuard®). Por sua vez, cada um deles foi dividido em 2 subgrupos (n=15), de acordo com ausência ou presença de sangue. Os canais radiculares foram totalmente obturados pelo respetivo material de cada grupo e posteriormente armazenados em estufa a 37ºC com humidade relativa de 100%. Após 1 semana, as amostras foram seccionadas em 3 segmentos com a espessura de 3 mm. Foi realizado o cálculo da área de adesão para cada amostra, a partir dos registos fotográficos das mesmas, recorrendo ao programa ImageJ para a medição de dois valores de raio do material de obturação nas duas faces da amostra. O teste de força de adesão push-out (MPa) foi realizado numa máquina de testes universais sendo obtido o valor máximo da força no momento de deslocamento do material. Foi ainda registado o tipo de falha. A análise estatística dos resultados foi realizada para um nível de significância de 0,05.Resultados: Os cimentos testados apresentavam diferenças estatisticamente significativas na força adesiva push-out. O cimento TotalFill BC putty apresentou os valores mais elevados de resistência ao deslocamento (10,31±8,41 MPa) e o Pulp Guard os valores mais baixos (1,13±0,68 MPa). Observamos também aquando a comparação da força adesiva do TotalFill BC putty com o Biodentine (8,54±4,49 MPa) e ProRoot MTA (7,44±4,07 MPa), valores significativamente inferiores. Verificamos que a ocorrência de um ambiente contaminado com sangue não altera signficativamente a força de adesão push-out nos materiais testados, à exceção do PulpGuard (p=0,0002). No que diz respeito às diferentes secções radiculares, não se verificam diferenças na resistência ao deslocamento (p>0,05). Todos os grupos revelaram uma forte predominância de falhas adesivas.Conclusão: Para os materiais testados, o cimento que apresenta maior força de adesão à dentina foi o TotalFill BC putty. O ambiente contaminado por sangue não exerceu nenhuma influência no desempenho dos materiais exceto para o PulpGuard.Introduction: The aim of this study is to determine the bond strenght of 4 bioceramic cements (ProRoot® MTA, Biodentine™, TotalFill BC RRM™ putty™ and PulpGuard®) to root dentin, with and without blood contamination, assessed through push-out tests. Material and Methods: A total of 120 human monoradicular teeth were collected, sectioned with a standardized root length of 15 mm and the canals were prepared until the Gates Glidden bur number four. The samples were divided into 4 groups, according to the material used (ProRoot® MTA, Biodentine™, TotalFill BC RRM™ putty and PulpGuard®). Then, each one was further divided into 2 subgroups (n=15), according to the absence or presence of blood contamination. The root canals were totally filled with the respective material of each group and posteriorly stored in an incubator, at 37ºC and 100% relative humidity. After 1 week, the roots were cut in 3 segments with 3 mm of thickness. The adhesion area was calculated for each sample, from the photographic records, using ImageJ software to measure two radius values of filling material from the two sides of the sample. The push-out test (MPa) was performed with a universal test machine and the maximum load value applied before material displacement was registered. Moreover, the failure type was classified. The statistical analysis was performed with a significance level of 0.05. Results: The tested cements showed statistically significant differences regarding the push-out adhesive force. TotalFill BC putty showed the highest values of displacement resistance (10.31 ± 8.41 MPa) and Pulp Guard the lowest (1.13 ± 0.68 MPa). It was also observed that Biodentine (8.54 ± 4.49 MPa) and ProRoot MTA (7.44 ± 4.07 MPa) bond strength values were significantly lower than TotalFill BC putty. The presence of a blood contaminated environment did not significantly alter the force values in any material, except for PulpGuard (p = 0.0002). Regarding the different sections, there are no differences in the resistance to displacement (p> 0.05). The failure pattern was mostly adhesive.Conclusion: Within the tested biomaterials, TotalFill BC putty showed the highest bond strength to the dentin. The blood contaminated environment had no influence on the materials performance except for PulpGuard.2019-07-192025-07-17T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10316/89615http://hdl.handle.net/10316/89615TID:202480437engPaulo, Sónia Cristina Rodriguesinfo:eu-repo/semantics/embargoedAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-10-27T10:56:13Zoai:estudogeral.uc.pt:10316/89615Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:09:52.918406Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Influence of blood contamination on adhesion of bioceramic materials to root dentin
Influência da contaminação sanguínea na adesão de materiais biocerâmicos à dentina radicular
title Influence of blood contamination on adhesion of bioceramic materials to root dentin
spellingShingle Influence of blood contamination on adhesion of bioceramic materials to root dentin
Paulo, Sónia Cristina Rodrigues
cimentos silicatos de cálcio
força adesiva push out
contaminação sanguínea
ProRoot MTA
Biodentine
calcium silicate-based cements
push out bond strength
blood contamination
ProRoot MTA
Biodentine
title_short Influence of blood contamination on adhesion of bioceramic materials to root dentin
title_full Influence of blood contamination on adhesion of bioceramic materials to root dentin
title_fullStr Influence of blood contamination on adhesion of bioceramic materials to root dentin
title_full_unstemmed Influence of blood contamination on adhesion of bioceramic materials to root dentin
title_sort Influence of blood contamination on adhesion of bioceramic materials to root dentin
author Paulo, Sónia Cristina Rodrigues
author_facet Paulo, Sónia Cristina Rodrigues
author_role author
dc.contributor.author.fl_str_mv Paulo, Sónia Cristina Rodrigues
dc.subject.por.fl_str_mv cimentos silicatos de cálcio
força adesiva push out
contaminação sanguínea
ProRoot MTA
Biodentine
calcium silicate-based cements
push out bond strength
blood contamination
ProRoot MTA
Biodentine
topic cimentos silicatos de cálcio
força adesiva push out
contaminação sanguínea
ProRoot MTA
Biodentine
calcium silicate-based cements
push out bond strength
blood contamination
ProRoot MTA
Biodentine
description Trabalho Final do Mestrado Integrado em Medicina Dentária apresentado à Faculdade de Medicina
publishDate 2019
dc.date.none.fl_str_mv 2019-07-19
2025-07-17T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/89615
http://hdl.handle.net/10316/89615
TID:202480437
url http://hdl.handle.net/10316/89615
identifier_str_mv TID:202480437
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/embargoedAccess
eu_rights_str_mv embargoedAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133993618112512