Rate effects in a proportional counter with resistive cathode

Detalhes bibliográficos
Autor(a) principal: Bueno, Carmen C.
Data de Publicação: 1998
Outros Autores: Fraga, M. M., Gonçalves, Josemary A. C., Marques, R. Ferreira, Policarpo, A. J. P. L., Santos, M. Damy de S.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/4568
https://doi.org/10.1016/S0168-9002(98)00197-1
Resumo: In this work, the rate effects associated with the gain of detectors with resistive electrodes are considered. To study these effects it was decided to use the classical proportional counter geometry, with a cylindrical glass tube as the cathode, rather than parallel plate devices. Indeed, the generality of the information obtained is not affected and the cylindrical proportional counter geometry has several advantages to gather detailed experimental data and to compare it with simple electric field calculations. A self-consistent set of data is presented for the effects of counting rate from a few tens of Hz up to several hundreds of Hz, using several gas mixtures, different anode wires, cathode radii and thickness of the resistive electrodes. Although a few sources of systematic errors can be identified, all the observed experimental data can be quantitatively explained. Indeed, the measured gas amplification, from a few tens up to ~5×104 and for the range of counting rates quoted above, depends only on the local electric field as it should be expected. These results are directly relevant to approach the problem of counting efficiency in resistive plate chambers.
id RCAP_7c7aa9e690df5fddf58f85efb5758f6a
oai_identifier_str oai:estudogeral.uc.pt:10316/4568
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Rate effects in a proportional counter with resistive cathodeProportional countersGaseous detectorsResistive cathodesIn this work, the rate effects associated with the gain of detectors with resistive electrodes are considered. To study these effects it was decided to use the classical proportional counter geometry, with a cylindrical glass tube as the cathode, rather than parallel plate devices. Indeed, the generality of the information obtained is not affected and the cylindrical proportional counter geometry has several advantages to gather detailed experimental data and to compare it with simple electric field calculations. A self-consistent set of data is presented for the effects of counting rate from a few tens of Hz up to several hundreds of Hz, using several gas mixtures, different anode wires, cathode radii and thickness of the resistive electrodes. Although a few sources of systematic errors can be identified, all the observed experimental data can be quantitatively explained. Indeed, the measured gas amplification, from a few tens up to ~5×104 and for the range of counting rates quoted above, depends only on the local electric field as it should be expected. These results are directly relevant to approach the problem of counting efficiency in resistive plate chambers.http://www.sciencedirect.com/science/article/B6TJM-3W54TFN-F/1/374c608315339b76fedce6123c890be51998info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/4568http://hdl.handle.net/10316/4568https://doi.org/10.1016/S0168-9002(98)00197-1engNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 408:2-3 (1998) 496-502Bueno, Carmen C.Fraga, M. M.Gonçalves, Josemary A. C.Marques, R. FerreiraPolicarpo, A. J. P. L.Santos, M. Damy de S.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2021-10-12T13:08:14Zoai:estudogeral.uc.pt:10316/4568Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:40.377156Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Rate effects in a proportional counter with resistive cathode
title Rate effects in a proportional counter with resistive cathode
spellingShingle Rate effects in a proportional counter with resistive cathode
Bueno, Carmen C.
Proportional counters
Gaseous detectors
Resistive cathodes
title_short Rate effects in a proportional counter with resistive cathode
title_full Rate effects in a proportional counter with resistive cathode
title_fullStr Rate effects in a proportional counter with resistive cathode
title_full_unstemmed Rate effects in a proportional counter with resistive cathode
title_sort Rate effects in a proportional counter with resistive cathode
author Bueno, Carmen C.
author_facet Bueno, Carmen C.
Fraga, M. M.
Gonçalves, Josemary A. C.
Marques, R. Ferreira
Policarpo, A. J. P. L.
Santos, M. Damy de S.
author_role author
author2 Fraga, M. M.
Gonçalves, Josemary A. C.
Marques, R. Ferreira
Policarpo, A. J. P. L.
Santos, M. Damy de S.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Bueno, Carmen C.
Fraga, M. M.
Gonçalves, Josemary A. C.
Marques, R. Ferreira
Policarpo, A. J. P. L.
Santos, M. Damy de S.
dc.subject.por.fl_str_mv Proportional counters
Gaseous detectors
Resistive cathodes
topic Proportional counters
Gaseous detectors
Resistive cathodes
description In this work, the rate effects associated with the gain of detectors with resistive electrodes are considered. To study these effects it was decided to use the classical proportional counter geometry, with a cylindrical glass tube as the cathode, rather than parallel plate devices. Indeed, the generality of the information obtained is not affected and the cylindrical proportional counter geometry has several advantages to gather detailed experimental data and to compare it with simple electric field calculations. A self-consistent set of data is presented for the effects of counting rate from a few tens of Hz up to several hundreds of Hz, using several gas mixtures, different anode wires, cathode radii and thickness of the resistive electrodes. Although a few sources of systematic errors can be identified, all the observed experimental data can be quantitatively explained. Indeed, the measured gas amplification, from a few tens up to ~5×104 and for the range of counting rates quoted above, depends only on the local electric field as it should be expected. These results are directly relevant to approach the problem of counting efficiency in resistive plate chambers.
publishDate 1998
dc.date.none.fl_str_mv 1998
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/4568
http://hdl.handle.net/10316/4568
https://doi.org/10.1016/S0168-9002(98)00197-1
url http://hdl.handle.net/10316/4568
https://doi.org/10.1016/S0168-9002(98)00197-1
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 408:2-3 (1998) 496-502
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv aplication/PDF
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133888240418816