Evaluation of posterior and total corneal astigmatism with colour-led topography

Detalhes bibliográficos
Autor(a) principal: Mendes, João Guilherme Ribeiro
Data de Publicação: 2021
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10451/52398
Resumo: Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2021
id RCAP_7d5d5b84239709e0c8457ef9e08c8a54
oai_identifier_str oai:repositorio.ul.pt:10451/52398
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Evaluation of posterior and total corneal astigmatism with colour-led topographyTopografiaTomografiaAstigmatismoAstigmatismo corneano totalAstigmatismo corneano posteriorOftalmologiaDomínio/Área Científica::Ciências MédicasTrabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2021A cirurgia da catarata é um dos procedimentos cirúrgicos mais antigos e bem-sucedidos em toda a Medicina, tendo evoluído para um procedimento refrativo através da utilização da lente intraocular (LIO) tórica. Para a correção do astigmatismo corneano e a obtenção da acuidade visual e independência de óculos desejadas, é necessário a aquisição pré-operatória precisa de parâmetros biométricos oculares e o cálculo preciso do poder esférico e cilíndrico da LIO a implantar. A acuidade visual é afetada pelo astigmatismo residual pós-cirúrgico, sendo que uma das fontes de erro mais importantes, durante o cálculo das LIO tóricas, é não considerar o astigmatismo da superfície posterior da córnea. Não ter em consideração a sua potência, resulta em sobrecorreção em olhos com astigmatismo a favor da regra (WTR) e subcorreção em olhos com astigmatismo contra a regra (ATR). Os tomógrafos baseados em tecnologia LED (light-emitting diode) fornecem medidas da curvatura posterior da córnea e astigmatismo. Num estudo recente, medidas da curvatura posterior da córnea usando tomógrafos baseados em tecnologia LED para a medição da curvatura anterior combinado com tecnologia Purkinje para a medição da curvatura posterior mostraram melhores resultados do que os tomógrafos baseados em tecnologia Scheimpflug no cálculo de LIOs. Atendendo a que os nomogramas e modelos matemáticos disponíveis atualmente, que consideram o astigmatismo posterior da córnea, são baseados em dados de tomógrafos que usam tecnologia Scheimpflug, surgiu a necessidade de caracterizar o astigmatismo corneano total e posterior utilizando uma nova tecnologia, introduzida em 2014, com o objetivo de melhorar os nomogramas e modelos matemáticos existentes. Devido à precisão limitada das tecnologias atuais e à falta de um método de eleição para a avaliação do astigmatismo corneano e particularmente do astigmatismo posterior da córnea, o conhecimento de parâmetros biométricos normativos é essencial para o cálculo das LIOs.Para além disso, todos os estudos que avaliaram o astigmatismo total e posterior da córnea basearam-se em tecnologia Scheimpflug, não tendo estes parâmetros sido avaliados por tecnologia LED numa amostra significativa de olhos normais. O objetivo deste estudo descritivo é caracterizar o astigmatismo total e posterior da córnea numa amostra significativa de olhos normais usando um tomógrafo baseado em tecnologia LED - Cassini (i-Optics, The Hague, The Netherlands) e avaliar a comparabilidade dos resultados obtidos com os tomógrafos baseados em tecnologia Scheimpflug e outros, suportando a consideração do astigmatismo corneano total na correção precisa do astigmatismo na cirurgia da catarata, melhorando a preditibilidade da correção e otimizando a qualidade visual dos doentes e consequentemente, a independência de óculos e a sua satisfação. Através da caracterização precisa do astigmatismo corneano total e posterior com esta nova tecnologia, tem-se como objetivo futuro melhorar os nomogramas e os modelos matemáticos existentes, baseando-se estes em dados biométricos mais completos e precisos.Cataract surgery is one of the oldest and most successful treatments in all of Medicine, having evolved into a refractive procedure with the use of toric intraocular lens (IOL). For the correction of corneal astigmatism and to obtain the desired visual acuity and spectacle independence, it is necessary to obtain precise preoperative ocular biometric parameters and precise calculation of the spherical and cylindrical power of the IOL to be implanted. Visual acuity is affected by the residual post-surgical astigmatism, and one of the most important sources of error, when calculating toric IOL, is not to consider astigmatism of the posterior corneal surface. Ignoring its power results in overcorrection in eyes with with-the-rule (WTR) astigmatism and under-correction in eyes with against-the-rule (ATR) astigmatism. Colour point-source light-emitting diodes (LED) tomography provides consistent measures of posterior corneal curvature and astigmatism. In a recent study, direct measurement of the anterior corneal surface with colour-LED tomography combined with Purkinje technology to measure the posterior corneal curvature showed better performance than a Scheimpflug camera in toric IOL calculation. Given that the nomograms and mathematical models currently available, which consider the posterior corneal astigmatism, are based on data from cameras using Scheimpflug technology, the need arose to characterize total and posterior corneal astigmatism using a new technology, introduced in 2014, to improve the existing nomograms and mathematical models. Accounting for the limited precision of current technologies and lack of a gold standard for evaluating corneal astigmatism and particularly the posterior corneal surface, knowledge of normative ocular biometric parameters is essential in IOL calculation. Furthermore, all the published studies that evaluated total and posterior corneal astigmatism used Scheimpflug technology, these parameters were not evaluated using colour-LED technology in a significant sample of normal eyes. The purpose of this study is to characterize the posterior and total corneal astigmatism in a large number of normal eyes using colour-LED tomography - Cassini (i-Optics, The Hague, The Netherlands) and evaluate the comparability with the data from Scheimpflug cameras and others, supporting the consideration of total corneal astigmatism in the precise correction of astigmatism in cataract surgery, improving the predictability of the correction and optimizing the visual quality of the patients and consequently, spectacle independence and satisfaction rates. Through the precise characterization of total and posterior corneal astigmatism with this new technology, the future objective is to improve the existing nomograms and mathematical models, based on more complete and accurate biometric data.Ribeiro, Maria Filomena JorgeRepositório da Universidade de LisboaMendes, João Guilherme Ribeiro2022-04-18T15:07:23Z2021-072021-07-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10451/52398TID:202903796enginfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-08T16:57:34Zoai:repositorio.ul.pt:10451/52398Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T22:03:30.527399Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Evaluation of posterior and total corneal astigmatism with colour-led topography
title Evaluation of posterior and total corneal astigmatism with colour-led topography
spellingShingle Evaluation of posterior and total corneal astigmatism with colour-led topography
Mendes, João Guilherme Ribeiro
Topografia
Tomografia
Astigmatismo
Astigmatismo corneano total
Astigmatismo corneano posterior
Oftalmologia
Domínio/Área Científica::Ciências Médicas
title_short Evaluation of posterior and total corneal astigmatism with colour-led topography
title_full Evaluation of posterior and total corneal astigmatism with colour-led topography
title_fullStr Evaluation of posterior and total corneal astigmatism with colour-led topography
title_full_unstemmed Evaluation of posterior and total corneal astigmatism with colour-led topography
title_sort Evaluation of posterior and total corneal astigmatism with colour-led topography
author Mendes, João Guilherme Ribeiro
author_facet Mendes, João Guilherme Ribeiro
author_role author
dc.contributor.none.fl_str_mv Ribeiro, Maria Filomena Jorge
Repositório da Universidade de Lisboa
dc.contributor.author.fl_str_mv Mendes, João Guilherme Ribeiro
dc.subject.por.fl_str_mv Topografia
Tomografia
Astigmatismo
Astigmatismo corneano total
Astigmatismo corneano posterior
Oftalmologia
Domínio/Área Científica::Ciências Médicas
topic Topografia
Tomografia
Astigmatismo
Astigmatismo corneano total
Astigmatismo corneano posterior
Oftalmologia
Domínio/Área Científica::Ciências Médicas
description Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2021
publishDate 2021
dc.date.none.fl_str_mv 2021-07
2021-07-01T00:00:00Z
2022-04-18T15:07:23Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10451/52398
TID:202903796
url http://hdl.handle.net/10451/52398
identifier_str_mv TID:202903796
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799134585473204224