Intra- and Interreader Variability of Orbital Volume Quantification Using 3D Computed Tomography for Reconstructed Orbital Fractures
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.17/3617 |
Resumo: | Purpose: Management of orbital fractures continues to present some difficulties, particularly regarding the prediction of late complications. Radiographic assessment provides a detailed evaluation, but the results lack consistency to be considered a standard factor in the decision-making process. Studies focusing on reliability of post-operative imaging are lacking. Materials and methods: We performed a retrospective study using patients from a major trauma center with unilateral orbital floor fracture who underwent surgery. Using three-dimensional volume assessment software, we performed a volume calculation and determined the intra- and interreader variation by intraclass correlation coefficient analysis. Results: Twenty-four orbits were assessed. Mean orbital volume (SD) was 24.02 (2,43) cm3 for reader 1 and 24.08 (2,51) cm3 for reader 2. The intraclass correlation coefficient (95% CI) was 0.95 (0.91-0.98) between readers and 0.96 (0.91-0.98) for intra-reader variability. Normal and reconstructed orbits assessed separately also showed very high correlation coefficient for both intra- and inter-subject variability. Conclusion: Results show an almost perfect agreement of volume assessment between readers. The presence of reconstruction material does not seem to add variability. Although reproducible and reliable, radiological volume assessments have not yet shown a clear correlation with clinical outcomes and post-operative management decisions should be based mainly on clinical findings. |
id |
RCAP_80b40bf329e409bd5a5152a414cacbee |
---|---|
oai_identifier_str |
oai:repositorio.chlc.min-saude.pt:10400.17/3617 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Intra- and Interreader Variability of Orbital Volume Quantification Using 3D Computed Tomography for Reconstructed Orbital FracturesHumansImaging, Three-DimensionalOrbitReconstructive Surgical ProceduresReproducibility of ResultsRetrospective StudiesTomography, X-Ray ComputedEnophthalmosOrbital FracturesHSJ CIR MAXFACHSJ NRADPurpose: Management of orbital fractures continues to present some difficulties, particularly regarding the prediction of late complications. Radiographic assessment provides a detailed evaluation, but the results lack consistency to be considered a standard factor in the decision-making process. Studies focusing on reliability of post-operative imaging are lacking. Materials and methods: We performed a retrospective study using patients from a major trauma center with unilateral orbital floor fracture who underwent surgery. Using three-dimensional volume assessment software, we performed a volume calculation and determined the intra- and interreader variation by intraclass correlation coefficient analysis. Results: Twenty-four orbits were assessed. Mean orbital volume (SD) was 24.02 (2,43) cm3 for reader 1 and 24.08 (2,51) cm3 for reader 2. The intraclass correlation coefficient (95% CI) was 0.95 (0.91-0.98) between readers and 0.96 (0.91-0.98) for intra-reader variability. Normal and reconstructed orbits assessed separately also showed very high correlation coefficient for both intra- and inter-subject variability. Conclusion: Results show an almost perfect agreement of volume assessment between readers. The presence of reconstruction material does not seem to add variability. Although reproducible and reliable, radiological volume assessments have not yet shown a clear correlation with clinical outcomes and post-operative management decisions should be based mainly on clinical findings.ElsevierRepositório do Centro Hospitalar Universitário de Lisboa Central, EPEGomes de Oliveira, PPerry da Câmara, CValejo Coelho, P2021-03-19T16:50:35Z2019-072019-07-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.17/3617engJ Craniomaxillofac Surg. 2019 Jul;47(7):1060-1064.10.1016/j.jcms.2019.04.010info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-10T09:43:47Zoai:repositorio.chlc.min-saude.pt:10400.17/3617Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:20:55.059533Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Intra- and Interreader Variability of Orbital Volume Quantification Using 3D Computed Tomography for Reconstructed Orbital Fractures |
title |
Intra- and Interreader Variability of Orbital Volume Quantification Using 3D Computed Tomography for Reconstructed Orbital Fractures |
spellingShingle |
Intra- and Interreader Variability of Orbital Volume Quantification Using 3D Computed Tomography for Reconstructed Orbital Fractures Gomes de Oliveira, P Humans Imaging, Three-Dimensional Orbit Reconstructive Surgical Procedures Reproducibility of Results Retrospective Studies Tomography, X-Ray Computed Enophthalmos Orbital Fractures HSJ CIR MAXFAC HSJ NRAD |
title_short |
Intra- and Interreader Variability of Orbital Volume Quantification Using 3D Computed Tomography for Reconstructed Orbital Fractures |
title_full |
Intra- and Interreader Variability of Orbital Volume Quantification Using 3D Computed Tomography for Reconstructed Orbital Fractures |
title_fullStr |
Intra- and Interreader Variability of Orbital Volume Quantification Using 3D Computed Tomography for Reconstructed Orbital Fractures |
title_full_unstemmed |
Intra- and Interreader Variability of Orbital Volume Quantification Using 3D Computed Tomography for Reconstructed Orbital Fractures |
title_sort |
Intra- and Interreader Variability of Orbital Volume Quantification Using 3D Computed Tomography for Reconstructed Orbital Fractures |
author |
Gomes de Oliveira, P |
author_facet |
Gomes de Oliveira, P Perry da Câmara, C Valejo Coelho, P |
author_role |
author |
author2 |
Perry da Câmara, C Valejo Coelho, P |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Repositório do Centro Hospitalar Universitário de Lisboa Central, EPE |
dc.contributor.author.fl_str_mv |
Gomes de Oliveira, P Perry da Câmara, C Valejo Coelho, P |
dc.subject.por.fl_str_mv |
Humans Imaging, Three-Dimensional Orbit Reconstructive Surgical Procedures Reproducibility of Results Retrospective Studies Tomography, X-Ray Computed Enophthalmos Orbital Fractures HSJ CIR MAXFAC HSJ NRAD |
topic |
Humans Imaging, Three-Dimensional Orbit Reconstructive Surgical Procedures Reproducibility of Results Retrospective Studies Tomography, X-Ray Computed Enophthalmos Orbital Fractures HSJ CIR MAXFAC HSJ NRAD |
description |
Purpose: Management of orbital fractures continues to present some difficulties, particularly regarding the prediction of late complications. Radiographic assessment provides a detailed evaluation, but the results lack consistency to be considered a standard factor in the decision-making process. Studies focusing on reliability of post-operative imaging are lacking. Materials and methods: We performed a retrospective study using patients from a major trauma center with unilateral orbital floor fracture who underwent surgery. Using three-dimensional volume assessment software, we performed a volume calculation and determined the intra- and interreader variation by intraclass correlation coefficient analysis. Results: Twenty-four orbits were assessed. Mean orbital volume (SD) was 24.02 (2,43) cm3 for reader 1 and 24.08 (2,51) cm3 for reader 2. The intraclass correlation coefficient (95% CI) was 0.95 (0.91-0.98) between readers and 0.96 (0.91-0.98) for intra-reader variability. Normal and reconstructed orbits assessed separately also showed very high correlation coefficient for both intra- and inter-subject variability. Conclusion: Results show an almost perfect agreement of volume assessment between readers. The presence of reconstruction material does not seem to add variability. Although reproducible and reliable, radiological volume assessments have not yet shown a clear correlation with clinical outcomes and post-operative management decisions should be based mainly on clinical findings. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-07 2019-07-01T00:00:00Z 2021-03-19T16:50:35Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.17/3617 |
url |
http://hdl.handle.net/10400.17/3617 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
J Craniomaxillofac Surg. 2019 Jul;47(7):1060-1064. 10.1016/j.jcms.2019.04.010 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799131305696296960 |