Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinic

Detalhes bibliográficos
Autor(a) principal: Galrinho, Bárbara
Data de Publicação: 2019
Outros Autores: São João, Ricardo, Salvado, Francisco
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.15/2768
Resumo: To evaluate bone loss after three years in implants placed at the implantology consult at the Egas Moniz University Clinic, relating bone loss to the type of loading (conventional or immediate load). A comparative and retrospective study, performed on a sample of 65 implants, placed in 24 of 327 patients, who attended the implantology consult at the Egas Moniz University Clinic in 2015, representing 7.3% of the study population through the measurement of distance between implant platform and bone using radiographs. Three years after implant placement with and without immediate loading there is statistically significant bone loss mesially and distally. It was found that when compared bone loss in loaded vs unloaded mesially and distally implants, there were no statistically significant differences. The bone loss of the unloaded implants was compared three years after being placed, with the bone level of the loaded implants also three years later. No significant difference was found. Although no statistically significant differences were found between bone loss in loaded implants vs unloaded mesially and distally, as it is supported by the literature, it was possible to conclude that there was, in fact, a statistically significant bone loss, mesially and distally, three years after implant placement with and without immediate loading. This may be due to poor oral hygiene, a history of periodontitis, smoking and peri-implantitis.
id RCAP_857256c8d1963b8996c75cbafa3ea90a
oai_identifier_str oai:repositorio.ipsantarem.pt:10400.15/2768
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinicImplantologyImmediate loadingConventional loadingRadiographsTo evaluate bone loss after three years in implants placed at the implantology consult at the Egas Moniz University Clinic, relating bone loss to the type of loading (conventional or immediate load). A comparative and retrospective study, performed on a sample of 65 implants, placed in 24 of 327 patients, who attended the implantology consult at the Egas Moniz University Clinic in 2015, representing 7.3% of the study population through the measurement of distance between implant platform and bone using radiographs. Three years after implant placement with and without immediate loading there is statistically significant bone loss mesially and distally. It was found that when compared bone loss in loaded vs unloaded mesially and distally implants, there were no statistically significant differences. The bone loss of the unloaded implants was compared three years after being placed, with the bone level of the loaded implants also three years later. No significant difference was found. Although no statistically significant differences were found between bone loss in loaded implants vs unloaded mesially and distally, as it is supported by the literature, it was possible to conclude that there was, in fact, a statistically significant bone loss, mesially and distally, three years after implant placement with and without immediate loading. This may be due to poor oral hygiene, a history of periodontitis, smoking and peri-implantitis.Panevėžio kolegija / University of Applied SciencesRepositório Científico do Instituto Politécnico de SantarémGalrinho, BárbaraSão João, RicardoSalvado, Francisco2020-01-06T11:24:04Z20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.15/2768engGalrinho, B., São João, R. & Salvado, F. (2019). Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinic. Taikomieji tyrimai studijose ir praktikoje - Applied research in studies and practice, 15 (1), 40-46.2029-1280info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-21T07:34:02Zoai:repositorio.ipsantarem.pt:10400.15/2768Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T01:54:41.804831Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinic
title Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinic
spellingShingle Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinic
Galrinho, Bárbara
Implantology
Immediate loading
Conventional loading
Radiographs
title_short Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinic
title_full Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinic
title_fullStr Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinic
title_full_unstemmed Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinic
title_sort Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinic
author Galrinho, Bárbara
author_facet Galrinho, Bárbara
São João, Ricardo
Salvado, Francisco
author_role author
author2 São João, Ricardo
Salvado, Francisco
author2_role author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Politécnico de Santarém
dc.contributor.author.fl_str_mv Galrinho, Bárbara
São João, Ricardo
Salvado, Francisco
dc.subject.por.fl_str_mv Implantology
Immediate loading
Conventional loading
Radiographs
topic Implantology
Immediate loading
Conventional loading
Radiographs
description To evaluate bone loss after three years in implants placed at the implantology consult at the Egas Moniz University Clinic, relating bone loss to the type of loading (conventional or immediate load). A comparative and retrospective study, performed on a sample of 65 implants, placed in 24 of 327 patients, who attended the implantology consult at the Egas Moniz University Clinic in 2015, representing 7.3% of the study population through the measurement of distance between implant platform and bone using radiographs. Three years after implant placement with and without immediate loading there is statistically significant bone loss mesially and distally. It was found that when compared bone loss in loaded vs unloaded mesially and distally implants, there were no statistically significant differences. The bone loss of the unloaded implants was compared three years after being placed, with the bone level of the loaded implants also three years later. No significant difference was found. Although no statistically significant differences were found between bone loss in loaded implants vs unloaded mesially and distally, as it is supported by the literature, it was possible to conclude that there was, in fact, a statistically significant bone loss, mesially and distally, three years after implant placement with and without immediate loading. This may be due to poor oral hygiene, a history of periodontitis, smoking and peri-implantitis.
publishDate 2019
dc.date.none.fl_str_mv 2019
2019-01-01T00:00:00Z
2020-01-06T11:24:04Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.15/2768
url http://hdl.handle.net/10400.15/2768
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Galrinho, B., São João, R. & Salvado, F. (2019). Retrospective comparative study of bone loss in implants with and without immediate loading in the Egas Moniz university clinic. Taikomieji tyrimai studijose ir praktikoje - Applied research in studies and practice, 15 (1), 40-46.
2029-1280
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Panevėžio kolegija / University of Applied Sciences
publisher.none.fl_str_mv Panevėžio kolegija / University of Applied Sciences
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1817553709443317760