Evaluation of analgesia after cesarean section.
Autor(a) principal: | |
---|---|
Data de Publicação: | 2001 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://www.actamedicaportuguesa.com/revista/index.php/amp/article/view/1864 |
Resumo: | The aim of this study was to evaluate the efficacy of post-caesarean analgesia comparing three techniques most frequently used.For three months all pregnant women submitted to elective or urgent caesarean section, under general or regional anaesthesia, were evaluate with a total of 129 parturient. These parturient were divided into three groups with different techniques of postoperative analgesia: Group 1 (n = 26) received intravenous pethidine and paracetamol per os, group 2 (n = 58) received epidural morphine and group 3 (n = 45) epidural morphine and intravenous propacetamol. Pain was assessed at rest and during mobilisation using a scale of 0-without pain, 1-mild pain, 2-moderate pain and 3-severe pain. Overall satisfaction was assessed with a verbal qualitative scale of very good, good, sufficient and bad. Side effects were analysed.The records of pain at rest and during mobilisation were significantly lower with epidural analgesia compared with intravenous pethidine. There were no significant differences between groups 2 and 3. Similar results were observed in the degree of satisfaction. For 50% of parturient of epidural analgesia (groups 2 and 3) and only 4% of intravenous pethidine (group 1) the analgesic technique was very good. Propacetamol and epidural morphine (group 3) had better pain scores (very good and good) when compared with morphine alone (group 2) but there were no significant differences. Epidural morphine was associated with more pruritus.From this study we are able to conclude that epidural morphine offers a good quality of analgesia with better satisfaction and minimal side effects. |
id |
RCAP_860a3f0e6ff46e3dbeef9be47ca24fcf |
---|---|
oai_identifier_str |
oai:ojs.www.actamedicaportuguesa.com:article/1864 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Evaluation of analgesia after cesarean section.Avaliação da analgesia após cesariana.The aim of this study was to evaluate the efficacy of post-caesarean analgesia comparing three techniques most frequently used.For three months all pregnant women submitted to elective or urgent caesarean section, under general or regional anaesthesia, were evaluate with a total of 129 parturient. These parturient were divided into three groups with different techniques of postoperative analgesia: Group 1 (n = 26) received intravenous pethidine and paracetamol per os, group 2 (n = 58) received epidural morphine and group 3 (n = 45) epidural morphine and intravenous propacetamol. Pain was assessed at rest and during mobilisation using a scale of 0-without pain, 1-mild pain, 2-moderate pain and 3-severe pain. Overall satisfaction was assessed with a verbal qualitative scale of very good, good, sufficient and bad. Side effects were analysed.The records of pain at rest and during mobilisation were significantly lower with epidural analgesia compared with intravenous pethidine. There were no significant differences between groups 2 and 3. Similar results were observed in the degree of satisfaction. For 50% of parturient of epidural analgesia (groups 2 and 3) and only 4% of intravenous pethidine (group 1) the analgesic technique was very good. Propacetamol and epidural morphine (group 3) had better pain scores (very good and good) when compared with morphine alone (group 2) but there were no significant differences. Epidural morphine was associated with more pruritus.From this study we are able to conclude that epidural morphine offers a good quality of analgesia with better satisfaction and minimal side effects.The aim of this study was to evaluate the efficacy of post-caesarean analgesia comparing three techniques most frequently used.For three months all pregnant women submitted to elective or urgent caesarean section, under general or regional anaesthesia, were evaluate with a total of 129 parturient. These parturient were divided into three groups with different techniques of postoperative analgesia: Group 1 (n = 26) received intravenous pethidine and paracetamol per os, group 2 (n = 58) received epidural morphine and group 3 (n = 45) epidural morphine and intravenous propacetamol. Pain was assessed at rest and during mobilisation using a scale of 0-without pain, 1-mild pain, 2-moderate pain and 3-severe pain. Overall satisfaction was assessed with a verbal qualitative scale of very good, good, sufficient and bad. Side effects were analysed.The records of pain at rest and during mobilisation were significantly lower with epidural analgesia compared with intravenous pethidine. There were no significant differences between groups 2 and 3. Similar results were observed in the degree of satisfaction. For 50% of parturient of epidural analgesia (groups 2 and 3) and only 4% of intravenous pethidine (group 1) the analgesic technique was very good. Propacetamol and epidural morphine (group 3) had better pain scores (very good and good) when compared with morphine alone (group 2) but there were no significant differences. Epidural morphine was associated with more pruritus.From this study we are able to conclude that epidural morphine offers a good quality of analgesia with better satisfaction and minimal side effects.Ordem dos Médicos2001-08-31info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://www.actamedicaportuguesa.com/revista/index.php/amp/article/view/1864oai:ojs.www.actamedicaportuguesa.com:article/1864Acta Médica Portuguesa; Vol. 14 No. 4 (2001): Julho-Agosto; 395-8Acta Médica Portuguesa; Vol. 14 N.º 4 (2001): Julho-Agosto; 395-81646-07580870-399Xreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPporhttps://www.actamedicaportuguesa.com/revista/index.php/amp/article/view/1864https://www.actamedicaportuguesa.com/revista/index.php/amp/article/view/1864/1440Ribeiro, INunes, FGhira, Minfo:eu-repo/semantics/openAccess2022-12-20T10:59:24Zoai:ojs.www.actamedicaportuguesa.com:article/1864Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:17:27.306717Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Evaluation of analgesia after cesarean section. Avaliação da analgesia após cesariana. |
title |
Evaluation of analgesia after cesarean section. |
spellingShingle |
Evaluation of analgesia after cesarean section. Ribeiro, I |
title_short |
Evaluation of analgesia after cesarean section. |
title_full |
Evaluation of analgesia after cesarean section. |
title_fullStr |
Evaluation of analgesia after cesarean section. |
title_full_unstemmed |
Evaluation of analgesia after cesarean section. |
title_sort |
Evaluation of analgesia after cesarean section. |
author |
Ribeiro, I |
author_facet |
Ribeiro, I Nunes, F Ghira, M |
author_role |
author |
author2 |
Nunes, F Ghira, M |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Ribeiro, I Nunes, F Ghira, M |
description |
The aim of this study was to evaluate the efficacy of post-caesarean analgesia comparing three techniques most frequently used.For three months all pregnant women submitted to elective or urgent caesarean section, under general or regional anaesthesia, were evaluate with a total of 129 parturient. These parturient were divided into three groups with different techniques of postoperative analgesia: Group 1 (n = 26) received intravenous pethidine and paracetamol per os, group 2 (n = 58) received epidural morphine and group 3 (n = 45) epidural morphine and intravenous propacetamol. Pain was assessed at rest and during mobilisation using a scale of 0-without pain, 1-mild pain, 2-moderate pain and 3-severe pain. Overall satisfaction was assessed with a verbal qualitative scale of very good, good, sufficient and bad. Side effects were analysed.The records of pain at rest and during mobilisation were significantly lower with epidural analgesia compared with intravenous pethidine. There were no significant differences between groups 2 and 3. Similar results were observed in the degree of satisfaction. For 50% of parturient of epidural analgesia (groups 2 and 3) and only 4% of intravenous pethidine (group 1) the analgesic technique was very good. Propacetamol and epidural morphine (group 3) had better pain scores (very good and good) when compared with morphine alone (group 2) but there were no significant differences. Epidural morphine was associated with more pruritus.From this study we are able to conclude that epidural morphine offers a good quality of analgesia with better satisfaction and minimal side effects. |
publishDate |
2001 |
dc.date.none.fl_str_mv |
2001-08-31 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.actamedicaportuguesa.com/revista/index.php/amp/article/view/1864 oai:ojs.www.actamedicaportuguesa.com:article/1864 |
url |
https://www.actamedicaportuguesa.com/revista/index.php/amp/article/view/1864 |
identifier_str_mv |
oai:ojs.www.actamedicaportuguesa.com:article/1864 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://www.actamedicaportuguesa.com/revista/index.php/amp/article/view/1864 https://www.actamedicaportuguesa.com/revista/index.php/amp/article/view/1864/1440 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Ordem dos Médicos |
publisher.none.fl_str_mv |
Ordem dos Médicos |
dc.source.none.fl_str_mv |
Acta Médica Portuguesa; Vol. 14 No. 4 (2001): Julho-Agosto; 395-8 Acta Médica Portuguesa; Vol. 14 N.º 4 (2001): Julho-Agosto; 395-8 1646-0758 0870-399X reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799130627761504256 |