Measuring retinal fluorescein leakage into the human vitreous with a modified confocal scanning laser ophthalmoscope
Autor(a) principal: | |
---|---|
Data de Publicação: | 2000 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://proa.ua.pt/index.php/revdeti/article/view/18348 |
Resumo: | A method is described to quantify blood-retinal barrier permeability to fluorescein. Data are collected from the vitreous of the human eye at two elapsed time intervals after intravenous fluorescein administration, using a modified confocal scanning laser ophthalmoscope. Data processing includes fundus image enhancement, image alignment, profile construction, filtering and interpolation, exponential fit and integration. Automatic determination of the center of fovea is obtained by a cross-correlation process. Grid overlapping on fundus images and on permeability maps allows for matching chorioretinal morphological structures with alterations of blood-retinal barrier permeability to fluorescein. |
id |
RCAP_8a839452d73395a0c2bbb1ba60c58ff6 |
---|---|
oai_identifier_str |
oai:proa.ua.pt:article/18348 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Measuring retinal fluorescein leakage into the human vitreous with a modified confocal scanning laser ophthalmoscopeA method is described to quantify blood-retinal barrier permeability to fluorescein. Data are collected from the vitreous of the human eye at two elapsed time intervals after intravenous fluorescein administration, using a modified confocal scanning laser ophthalmoscope. Data processing includes fundus image enhancement, image alignment, profile construction, filtering and interpolation, exponential fit and integration. Automatic determination of the center of fovea is obtained by a cross-correlation process. Grid overlapping on fundus images and on permeability maps allows for matching chorioretinal morphological structures with alterations of blood-retinal barrier permeability to fluorescein.Descreve-se neste trabalho um método de quantificação de um índice de permeabilidade da barreira hemato-retiniana para a fluoresceína. Os dados são obtidos no vítreo do olho humano em tempos diferentes após administração intravenosa de fluoresceína por um sistema com focal de varrimento laser modificado. O processamento inclui o aumento de contraste da imagem do fundo ocular, alinhamento de imagens, construção, filtragem e interpolação de perfis, ajuste exponencial e integração. A determinação automática do centro da fovea é obtida por um processo de correlação cruzada. Uma grelha é sobreposta na imagem da retina e no mapa de índices de permeabilidade, o que permite uma mais fácil correlação entre as estruturas da retina e as alterações da permeabilidade da barreira hemato-retiniana para a fluoresceína.UA Editora2000-01-01T00:00:00Zconference objectconference objectinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://proa.ua.pt/index.php/revdeti/article/view/18348oai:proa.ua.pt:article/18348Eletrónica e Telecomunicações; Vol 3 No 2 (2000); 180-186Eletrónica e Telecomunicações; vol. 3 n.º 2 (2000); 180-1862182-97721645-0493reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttps://proa.ua.pt/index.php/revdeti/article/view/18348https://proa.ua.pt/index.php/revdeti/article/view/18348/13230https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessBernardes, Rui C.Lobo, Conceição L.Cunha-Vaz, José G.2022-09-26T11:00:26Zoai:proa.ua.pt:article/18348Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:08:34.363526Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Measuring retinal fluorescein leakage into the human vitreous with a modified confocal scanning laser ophthalmoscope |
title |
Measuring retinal fluorescein leakage into the human vitreous with a modified confocal scanning laser ophthalmoscope |
spellingShingle |
Measuring retinal fluorescein leakage into the human vitreous with a modified confocal scanning laser ophthalmoscope Bernardes, Rui C. |
title_short |
Measuring retinal fluorescein leakage into the human vitreous with a modified confocal scanning laser ophthalmoscope |
title_full |
Measuring retinal fluorescein leakage into the human vitreous with a modified confocal scanning laser ophthalmoscope |
title_fullStr |
Measuring retinal fluorescein leakage into the human vitreous with a modified confocal scanning laser ophthalmoscope |
title_full_unstemmed |
Measuring retinal fluorescein leakage into the human vitreous with a modified confocal scanning laser ophthalmoscope |
title_sort |
Measuring retinal fluorescein leakage into the human vitreous with a modified confocal scanning laser ophthalmoscope |
author |
Bernardes, Rui C. |
author_facet |
Bernardes, Rui C. Lobo, Conceição L. Cunha-Vaz, José G. |
author_role |
author |
author2 |
Lobo, Conceição L. Cunha-Vaz, José G. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Bernardes, Rui C. Lobo, Conceição L. Cunha-Vaz, José G. |
description |
A method is described to quantify blood-retinal barrier permeability to fluorescein. Data are collected from the vitreous of the human eye at two elapsed time intervals after intravenous fluorescein administration, using a modified confocal scanning laser ophthalmoscope. Data processing includes fundus image enhancement, image alignment, profile construction, filtering and interpolation, exponential fit and integration. Automatic determination of the center of fovea is obtained by a cross-correlation process. Grid overlapping on fundus images and on permeability maps allows for matching chorioretinal morphological structures with alterations of blood-retinal barrier permeability to fluorescein. |
publishDate |
2000 |
dc.date.none.fl_str_mv |
2000-01-01T00:00:00Z |
dc.type.driver.fl_str_mv |
conference object conference object info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://proa.ua.pt/index.php/revdeti/article/view/18348 oai:proa.ua.pt:article/18348 |
url |
https://proa.ua.pt/index.php/revdeti/article/view/18348 |
identifier_str_mv |
oai:proa.ua.pt:article/18348 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://proa.ua.pt/index.php/revdeti/article/view/18348 https://proa.ua.pt/index.php/revdeti/article/view/18348/13230 |
dc.rights.driver.fl_str_mv |
https://creativecommons.org/licenses/by/4.0/ info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0/ |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
UA Editora |
publisher.none.fl_str_mv |
UA Editora |
dc.source.none.fl_str_mv |
Eletrónica e Telecomunicações; Vol 3 No 2 (2000); 180-186 Eletrónica e Telecomunicações; vol. 3 n.º 2 (2000); 180-186 2182-9772 1645-0493 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799130543038660608 |