Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study

Detalhes bibliográficos
Autor(a) principal: Macedo-de-Araújo, Rute J.
Data de Publicação: 2023
Outros Autores: Seco, Rita Maria, González-Méijome, José Manuel
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://hdl.handle.net/1822/87546
Resumo: Purpose: To investigate the long-term influence of scleral lens (SL) wear on corneal biomechanical properties and intraocular pressure (IOP) in irregular and regular corneas. Secondary goal comprised evaluate the fluid reservoir (FR) thickness overtime and correlate it with the changes in corneal biomechanical parameters and IOP. Methods: Seventy (70) eyes with irregular corneas (IC Group) and 21 eyes with regular corneas (RC Group) were fitted with 16.4 mm SL and wore the lenses for 12 months. Corrected IOP (IOPcc), Goldmann equivalent IOP (IOPg) and corneal biomechanical parameters (Corneal Hysteresis (CH) and Corneal Resistance Factor (CRF)) were measured with Ocular Response Analyzer. Slit lamp images were analyzed with ImageJ software to assess FR thickness overtime. Measurements were taken at lens dispensing visit prior lens wear (LDV1) and after 60 min of lens wear (LDV2) and at 1, 6 and 12-month follow-up visits. Measurements were done immediately after lens removal. Results: There were no statistically significant differences on IOPcc, IOPg, CRF and CH over the follow-up visits in both groups. Mean IOPcc and IOPg fluctuations overtime were clinically insignificant and below 1 mmHg in both groups. IOPg, CH and CRF were significantly lower on IC Group (p < 0.001), although no statistically significant differences were found between groups for IOPcc. Regarding FR thickness, statistically significant differences were found over the follow-up on both groups, with a mean decrease of 186.29 µm on IC Group and 175.32 µm on RC Group (p < 0.001). Statistically significant moderate to high negative correlations between FR and IOPg, CRF and CH were found only in the RC Group. Conclusions: Long-term SL wear was not associated to changes in corneal biomechanical parameters neither on IOP as measured after lens removal. Besides IOP measurement without SL removal, more studies are needed to investigate the potential relationship with SL fitting characteristics (namely FR thickness).
id RCAP_8ca7ff7196726c0d020f6d6db34b101b
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/87546
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up studyCorneal biomechanicsIntraocular pressureScleral lensPurpose: To investigate the long-term influence of scleral lens (SL) wear on corneal biomechanical properties and intraocular pressure (IOP) in irregular and regular corneas. Secondary goal comprised evaluate the fluid reservoir (FR) thickness overtime and correlate it with the changes in corneal biomechanical parameters and IOP. Methods: Seventy (70) eyes with irregular corneas (IC Group) and 21 eyes with regular corneas (RC Group) were fitted with 16.4 mm SL and wore the lenses for 12 months. Corrected IOP (IOPcc), Goldmann equivalent IOP (IOPg) and corneal biomechanical parameters (Corneal Hysteresis (CH) and Corneal Resistance Factor (CRF)) were measured with Ocular Response Analyzer. Slit lamp images were analyzed with ImageJ software to assess FR thickness overtime. Measurements were taken at lens dispensing visit prior lens wear (LDV1) and after 60 min of lens wear (LDV2) and at 1, 6 and 12-month follow-up visits. Measurements were done immediately after lens removal. Results: There were no statistically significant differences on IOPcc, IOPg, CRF and CH over the follow-up visits in both groups. Mean IOPcc and IOPg fluctuations overtime were clinically insignificant and below 1 mmHg in both groups. IOPg, CH and CRF were significantly lower on IC Group (p < 0.001), although no statistically significant differences were found between groups for IOPcc. Regarding FR thickness, statistically significant differences were found over the follow-up on both groups, with a mean decrease of 186.29 µm on IC Group and 175.32 µm on RC Group (p < 0.001). Statistically significant moderate to high negative correlations between FR and IOPg, CRF and CH were found only in the RC Group. Conclusions: Long-term SL wear was not associated to changes in corneal biomechanical parameters neither on IOP as measured after lens removal. Besides IOP measurement without SL removal, more studies are needed to investigate the potential relationship with SL fitting characteristics (namely FR thickness).This project was supported in part by an unrestricted grant from Bausch & Lomb (Rochester, USA) and projects PTDC/SAU-BEB/098391/2008, PTDC/SAU-BEB/098392/2008 and the Strategic Fund ing UID/FIS/04650/2013. Authors declare that they do not have any proprietary or financial interest in any of the materials mentioned in this article. Authors thank Procornea (Netherlands) for their valuable cooperation.ElsevierUniversidade do MinhoMacedo-de-Araújo, Rute J.Seco, Rita MariaGonzález-Méijome, José Manuel20232023-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/1822/87546engMacedo-de-Araújo, R. J., Seco, R. M., & González-Méijome, J. M. (2023, December). Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study. Contact Lens and Anterior Eye. Elsevier BV. http://doi.org/10.1016/j.clae.2023.1020671367-048410.1016/j.clae.2023.1020673786371437863714https://www.sciencedirect.com/science/article/pii/S1367048423003016info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-12-16T01:20:05Zoai:repositorium.sdum.uminho.pt:1822/87546Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:54:22.154399Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study
title Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study
spellingShingle Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study
Macedo-de-Araújo, Rute J.
Corneal biomechanics
Intraocular pressure
Scleral lens
title_short Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study
title_full Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study
title_fullStr Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study
title_full_unstemmed Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study
title_sort Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study
author Macedo-de-Araújo, Rute J.
author_facet Macedo-de-Araújo, Rute J.
Seco, Rita Maria
González-Méijome, José Manuel
author_role author
author2 Seco, Rita Maria
González-Méijome, José Manuel
author2_role author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Macedo-de-Araújo, Rute J.
Seco, Rita Maria
González-Méijome, José Manuel
dc.subject.por.fl_str_mv Corneal biomechanics
Intraocular pressure
Scleral lens
topic Corneal biomechanics
Intraocular pressure
Scleral lens
description Purpose: To investigate the long-term influence of scleral lens (SL) wear on corneal biomechanical properties and intraocular pressure (IOP) in irregular and regular corneas. Secondary goal comprised evaluate the fluid reservoir (FR) thickness overtime and correlate it with the changes in corneal biomechanical parameters and IOP. Methods: Seventy (70) eyes with irregular corneas (IC Group) and 21 eyes with regular corneas (RC Group) were fitted with 16.4 mm SL and wore the lenses for 12 months. Corrected IOP (IOPcc), Goldmann equivalent IOP (IOPg) and corneal biomechanical parameters (Corneal Hysteresis (CH) and Corneal Resistance Factor (CRF)) were measured with Ocular Response Analyzer. Slit lamp images were analyzed with ImageJ software to assess FR thickness overtime. Measurements were taken at lens dispensing visit prior lens wear (LDV1) and after 60 min of lens wear (LDV2) and at 1, 6 and 12-month follow-up visits. Measurements were done immediately after lens removal. Results: There were no statistically significant differences on IOPcc, IOPg, CRF and CH over the follow-up visits in both groups. Mean IOPcc and IOPg fluctuations overtime were clinically insignificant and below 1 mmHg in both groups. IOPg, CH and CRF were significantly lower on IC Group (p < 0.001), although no statistically significant differences were found between groups for IOPcc. Regarding FR thickness, statistically significant differences were found over the follow-up on both groups, with a mean decrease of 186.29 µm on IC Group and 175.32 µm on RC Group (p < 0.001). Statistically significant moderate to high negative correlations between FR and IOPg, CRF and CH were found only in the RC Group. Conclusions: Long-term SL wear was not associated to changes in corneal biomechanical parameters neither on IOP as measured after lens removal. Besides IOP measurement without SL removal, more studies are needed to investigate the potential relationship with SL fitting characteristics (namely FR thickness).
publishDate 2023
dc.date.none.fl_str_mv 2023
2023-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/87546
url https://hdl.handle.net/1822/87546
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Macedo-de-Araújo, R. J., Seco, R. M., & González-Méijome, J. M. (2023, December). Prospective assessment of corneal biomechanical properties and intraocular pressure after scleral lens wear: A 12-month follow-up study. Contact Lens and Anterior Eye. Elsevier BV. http://doi.org/10.1016/j.clae.2023.102067
1367-0484
10.1016/j.clae.2023.102067
37863714
37863714
https://www.sciencedirect.com/science/article/pii/S1367048423003016
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799136431802679296