Preliminary results on position reconstruction for ZEPLIN III
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , , , , , , , , , , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10316/4380 https://doi.org/10.1016/j.nima.2006.10.254 |
Resumo: | ZEPLIN III is a two-phase xenon detector for direct dark matter search that will look for rare nuclear recoils from elastic scattering of Weakly Interacting Massive Particles off xenon atoms. ZEPLIN III measures both the scintillation and ionisation signals produced in the liquid by the interacting particle. The prompt scintillation is detected by an array of 31 photomultipliers (PM) immersed in the liquid, and a strong electric field extracts the ionisation electrons to the vapour phase. Electroluminescence photons are produced in the gas and detected by the same PM array. In this paper we describe position reconstruction methods that use both these signals to achieve a position accuracy of a few millimetres in the horizontal plane and sub-millimetre in the vertical coordinate. |
id |
RCAP_9147e88491a4b1ea3079e26737701148 |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/4380 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Preliminary results on position reconstruction for ZEPLIN IIIDetectorsPositionReconstructionZEPLIN III is a two-phase xenon detector for direct dark matter search that will look for rare nuclear recoils from elastic scattering of Weakly Interacting Massive Particles off xenon atoms. ZEPLIN III measures both the scintillation and ionisation signals produced in the liquid by the interacting particle. The prompt scintillation is detected by an array of 31 photomultipliers (PM) immersed in the liquid, and a strong electric field extracts the ionisation electrons to the vapour phase. Electroluminescence photons are produced in the gas and detected by the same PM array. In this paper we describe position reconstruction methods that use both these signals to achieve a position accuracy of a few millimetres in the horizontal plane and sub-millimetre in the vertical coordinate.http://www.sciencedirect.com/science/article/B6TJM-4MD310K-D/1/a5d0b57794dcd67b6d2dd09a098299d62007info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/4380http://hdl.handle.net/10316/4380https://doi.org/10.1016/j.nima.2006.10.254engNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 573:1-2 (2007) 200-203Lindote, A.Araújo, H. M.Cunha, J. Pinto daAkimov, D. Yu.Chepel, V.Davidge, D.Dawson, J. V.Joshi, M.Lebedenko, V. N.Liubarsky, I.Lopes, M. I.Neves, F.Quenby, J. J.Silva, C.Solovov, V.Sumner, T. J.Thorne, C.Walker, R. J.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2021-11-02T09:08:44Zoai:estudogeral.uc.pt:10316/4380Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:59:33.503219Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Preliminary results on position reconstruction for ZEPLIN III |
title |
Preliminary results on position reconstruction for ZEPLIN III |
spellingShingle |
Preliminary results on position reconstruction for ZEPLIN III Lindote, A. Detectors Position Reconstruction |
title_short |
Preliminary results on position reconstruction for ZEPLIN III |
title_full |
Preliminary results on position reconstruction for ZEPLIN III |
title_fullStr |
Preliminary results on position reconstruction for ZEPLIN III |
title_full_unstemmed |
Preliminary results on position reconstruction for ZEPLIN III |
title_sort |
Preliminary results on position reconstruction for ZEPLIN III |
author |
Lindote, A. |
author_facet |
Lindote, A. Araújo, H. M. Cunha, J. Pinto da Akimov, D. Yu. Chepel, V. Davidge, D. Dawson, J. V. Joshi, M. Lebedenko, V. N. Liubarsky, I. Lopes, M. I. Neves, F. Quenby, J. J. Silva, C. Solovov, V. Sumner, T. J. Thorne, C. Walker, R. J. |
author_role |
author |
author2 |
Araújo, H. M. Cunha, J. Pinto da Akimov, D. Yu. Chepel, V. Davidge, D. Dawson, J. V. Joshi, M. Lebedenko, V. N. Liubarsky, I. Lopes, M. I. Neves, F. Quenby, J. J. Silva, C. Solovov, V. Sumner, T. J. Thorne, C. Walker, R. J. |
author2_role |
author author author author author author author author author author author author author author author author author |
dc.contributor.author.fl_str_mv |
Lindote, A. Araújo, H. M. Cunha, J. Pinto da Akimov, D. Yu. Chepel, V. Davidge, D. Dawson, J. V. Joshi, M. Lebedenko, V. N. Liubarsky, I. Lopes, M. I. Neves, F. Quenby, J. J. Silva, C. Solovov, V. Sumner, T. J. Thorne, C. Walker, R. J. |
dc.subject.por.fl_str_mv |
Detectors Position Reconstruction |
topic |
Detectors Position Reconstruction |
description |
ZEPLIN III is a two-phase xenon detector for direct dark matter search that will look for rare nuclear recoils from elastic scattering of Weakly Interacting Massive Particles off xenon atoms. ZEPLIN III measures both the scintillation and ionisation signals produced in the liquid by the interacting particle. The prompt scintillation is detected by an array of 31 photomultipliers (PM) immersed in the liquid, and a strong electric field extracts the ionisation electrons to the vapour phase. Electroluminescence photons are produced in the gas and detected by the same PM array. In this paper we describe position reconstruction methods that use both these signals to achieve a position accuracy of a few millimetres in the horizontal plane and sub-millimetre in the vertical coordinate. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10316/4380 http://hdl.handle.net/10316/4380 https://doi.org/10.1016/j.nima.2006.10.254 |
url |
http://hdl.handle.net/10316/4380 https://doi.org/10.1016/j.nima.2006.10.254 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 573:1-2 (2007) 200-203 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
aplication/PDF |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133887215960065 |