Mammography image quality: pectoral major muscle presentation in the mediolateral oblique view
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://doi.org/10.25758/set.1361 |
Resumo: | The mammography technique is, currently, the most reliable imaging method for the diagnosis of breast cancer, and for this reason, it is essential the production of mammograms with high quality and consistency. Considering that the goal of mammography is to maximize the visualization of breast tissue, the aim of this work is to explore the presentation of the pectoral major muscle in the mammographic image. We intended to assess the relationship between the technical procedures of the image acquisition and the presentation of the muscle, according to the current mammography quality criteria. The mammograms were collected from two reference hospitals in Porto, and thereafter, the image processing and statistical analysis were performed to assess qualitative and quantitative indicators of the image quality. In general, analyzing both clinical institutions and based on these indicators, the hospital that uses a fixed angulation of the potter-bucky apart from the patient's body habitus presented better results. This indicates that the existence of failures due to positioning errors is smaller when compared to the quality standard assessed. It was found, therefore, that the angulation of the potter-bucky device has a relevant and statistical significance on the quality of the mammographic images produced. |
id |
RCAP_915ce3020ae3df3a3f7d2e7969935135 |
---|---|
oai_identifier_str |
oai:journals.ipl.pt:article/577 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Mammography image quality: pectoral major muscle presentation in the mediolateral oblique viewQualidade de imagem em mamografia: apresentação do músculo grande peitoral na incidência oblíqua médio-lateralMamografiaOblíqua médio-lateral (OML)Execução técnicaQualidade de imagemMúsculo grande peitoralCritérios de qualidade mamográficaMammographyMediolateral oblique viewTechnical procedureImage qualityPectoral major muscleMammography quality standardsThe mammography technique is, currently, the most reliable imaging method for the diagnosis of breast cancer, and for this reason, it is essential the production of mammograms with high quality and consistency. Considering that the goal of mammography is to maximize the visualization of breast tissue, the aim of this work is to explore the presentation of the pectoral major muscle in the mammographic image. We intended to assess the relationship between the technical procedures of the image acquisition and the presentation of the muscle, according to the current mammography quality criteria. The mammograms were collected from two reference hospitals in Porto, and thereafter, the image processing and statistical analysis were performed to assess qualitative and quantitative indicators of the image quality. In general, analyzing both clinical institutions and based on these indicators, the hospital that uses a fixed angulation of the potter-bucky apart from the patient's body habitus presented better results. This indicates that the existence of failures due to positioning errors is smaller when compared to the quality standard assessed. It was found, therefore, that the angulation of the potter-bucky device has a relevant and statistical significance on the quality of the mammographic images produced.A mamografia é, atualmente, o principal método de diagnóstico imagiológico da patologia mamária, sendo, por isso, essencial a produção consistente de imagens mamográficas de elevada qualidade. Assim, e uma vez que a mamografia visa a maximização da visualização do tecido mamário, o principal objetivo deste estudo consiste em investigar a apresentação mamográfica do músculo grande peitoral na incidência oblíqua médio-lateral (OML) da mama. Pretendeu-se relacionar os padrões técnicos de aquisição de imagem à forma de apresentação do referido músculo, avaliando-os de acordo com os atuais critérios de qualidade de imagem. As imagens mamográficas foram recolhidas a partir de duas instituições hospitalares de referência do Porto, sendo posteriormente efetuada uma análise e tratamento estatístico dos indicadores qualitativos e quantitativos de qualidade das mesmas. Numa análise global por instituição, e tendo por base estes indicadores, a instituição que utiliza uma angulação fixa do potter-bucky, independentemente do biótipo corporal da paciente, apresentou resultados melhores, indicando assim que a existência de falhas devido a erros de posicionamento é menor por comparação aos critérios de qualidade padrão. Constatou-se, portanto, que a angulação do potter-bucky tem um impacto relevante e estatisticamente significativo na qualidade das imagens mamográficas.Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa)2022-08-25info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://doi.org/10.25758/set.1361oai:journals.ipl.pt:article/577Saúde e Tecnologia; No. 15 (2016): Maio 2016; 28-33Saúde & Tecnologia; N.º 15 (2016): Maio 2016; 28-331646-9704reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPporhttps://journals.ipl.pt/stecnologia/article/view/577https://doi.org/10.25758/set.1361https://journals.ipl.pt/stecnologia/article/view/577/504Direitos de Autor (c) 2022 Saúde & Tecnologiainfo:eu-repo/semantics/openAccessMota, Joana P. SantosVentura, Sandra M. Rua2022-12-20T10:58:58Zoai:journals.ipl.pt:article/577Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:21:23.812285Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Mammography image quality: pectoral major muscle presentation in the mediolateral oblique view Qualidade de imagem em mamografia: apresentação do músculo grande peitoral na incidência oblíqua médio-lateral |
title |
Mammography image quality: pectoral major muscle presentation in the mediolateral oblique view |
spellingShingle |
Mammography image quality: pectoral major muscle presentation in the mediolateral oblique view Mota, Joana P. Santos Mamografia Oblíqua médio-lateral (OML) Execução técnica Qualidade de imagem Músculo grande peitoral Critérios de qualidade mamográfica Mammography Mediolateral oblique view Technical procedure Image quality Pectoral major muscle Mammography quality standards |
title_short |
Mammography image quality: pectoral major muscle presentation in the mediolateral oblique view |
title_full |
Mammography image quality: pectoral major muscle presentation in the mediolateral oblique view |
title_fullStr |
Mammography image quality: pectoral major muscle presentation in the mediolateral oblique view |
title_full_unstemmed |
Mammography image quality: pectoral major muscle presentation in the mediolateral oblique view |
title_sort |
Mammography image quality: pectoral major muscle presentation in the mediolateral oblique view |
author |
Mota, Joana P. Santos |
author_facet |
Mota, Joana P. Santos Ventura, Sandra M. Rua |
author_role |
author |
author2 |
Ventura, Sandra M. Rua |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Mota, Joana P. Santos Ventura, Sandra M. Rua |
dc.subject.por.fl_str_mv |
Mamografia Oblíqua médio-lateral (OML) Execução técnica Qualidade de imagem Músculo grande peitoral Critérios de qualidade mamográfica Mammography Mediolateral oblique view Technical procedure Image quality Pectoral major muscle Mammography quality standards |
topic |
Mamografia Oblíqua médio-lateral (OML) Execução técnica Qualidade de imagem Músculo grande peitoral Critérios de qualidade mamográfica Mammography Mediolateral oblique view Technical procedure Image quality Pectoral major muscle Mammography quality standards |
description |
The mammography technique is, currently, the most reliable imaging method for the diagnosis of breast cancer, and for this reason, it is essential the production of mammograms with high quality and consistency. Considering that the goal of mammography is to maximize the visualization of breast tissue, the aim of this work is to explore the presentation of the pectoral major muscle in the mammographic image. We intended to assess the relationship between the technical procedures of the image acquisition and the presentation of the muscle, according to the current mammography quality criteria. The mammograms were collected from two reference hospitals in Porto, and thereafter, the image processing and statistical analysis were performed to assess qualitative and quantitative indicators of the image quality. In general, analyzing both clinical institutions and based on these indicators, the hospital that uses a fixed angulation of the potter-bucky apart from the patient's body habitus presented better results. This indicates that the existence of failures due to positioning errors is smaller when compared to the quality standard assessed. It was found, therefore, that the angulation of the potter-bucky device has a relevant and statistical significance on the quality of the mammographic images produced. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-08-25 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://doi.org/10.25758/set.1361 oai:journals.ipl.pt:article/577 |
url |
https://doi.org/10.25758/set.1361 |
identifier_str_mv |
oai:journals.ipl.pt:article/577 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://journals.ipl.pt/stecnologia/article/view/577 https://doi.org/10.25758/set.1361 https://journals.ipl.pt/stecnologia/article/view/577/504 |
dc.rights.driver.fl_str_mv |
Direitos de Autor (c) 2022 Saúde & Tecnologia info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Direitos de Autor (c) 2022 Saúde & Tecnologia |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa) |
publisher.none.fl_str_mv |
Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa) |
dc.source.none.fl_str_mv |
Saúde e Tecnologia; No. 15 (2016): Maio 2016; 28-33 Saúde & Tecnologia; N.º 15 (2016): Maio 2016; 28-33 1646-9704 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1817550779122188288 |