Accuracy of intraoral digital impressions and conventional impressions: at the level of partial removable prostheses.

Detalhes bibliográficos
Autor(a) principal: Sousa, Vera Lúcia Azevedo de
Data de Publicação: 2017
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/81980
Resumo: Trabalho de Projeto do Mestrado Integrado em Medicina Dentária apresentado à Faculdade de Medicina
id RCAP_91e0c33be79e3aab6405546ace1e13f4
oai_identifier_str oai:estudogeral.uc.pt:10316/81980
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Accuracy of intraoral digital impressions and conventional impressions: at the level of partial removable prostheses.Precisão das impressões intra-orais digitais e convencionais: ao nível da prótese removívelimpressão intra-oral digitalimpressão convencionalprótese parcial removívelCerec inLab SW15.0Cerec Omnicamintraoral digital impressionconventional impressionpartial removable prosthesesCerec OmnicamCerec inLab SW 15.0Trabalho de Projeto do Mestrado Integrado em Medicina Dentária apresentado à Faculdade de MedicinaIntrodução: A introdução do sistema CAD/CAM permite utilizar ficheiros STL obtidos por uma câmara intra-oral para confeção de próteses removíveis em modelos 3D, com a ausência do envio de modelos de gesso ou impressões convencionais em silicone ou alginato para o laboratório.Materiais e Métodos: Realizou-se uma revisão bibliográfica na base de dados PubMed com a combinação de palavras-chave e conectores Booleanos: “removable dentures” OR “removable prostheses” AND (“digital impression technique” OR “CAD/CAM”) NOT “fixed prostheses”, seguida de uma segunda revisão nas bases de dados PubMed, Web of ScienceTM, B-On, ClinicalKey® e ScienceDirect com a combinação: “CAD/CAM” AND “Intraoral digital impression” AND “Prosthodontic”. O estudo clínico piloto consistiu na realização, em 3 doentes, de duas impressões convencionais em alginato e duas impressões digitais intraorais com o scanner Cerec Omnicam (Dentsply Sirona, Wals, Áustria), efetuadas pelo mesmo operador. Os dois modelos de gesso obtidos das impressões convencionais foram digitalizados, pelo mesmo scanner, e as duas imagens resultantes foram sobrepostas, assim como as duas imagens das impressões digitais. Seguiu-se a análise através de medições lineares no software Cerec inLab SW 15.0 (Sirona Dental Systems, Wals, Áustria).Resultados: Na revisão bibliográfica obtivemos 35 artigos na Pubmed. Após leitura do título, abstract e aplicando os critérios de inclusão, selecionamos 4 artigos. Atráves das bases de dados ClinicalKey®, B-On, Web of ScienceTM e ScienceDirect selecionamos 14 artigos e 5 por referência cruzada manual, ficando com 23 artigos. Na análise das imagens, realizamos medições lineares, horizontais e verticais, para verificar a exatidão e a precisão, respectivamente. A exatidão variou em média 0,31mm e 0,49mm entre o modelo de referência e os modelos virtuais obtido pela digitalização do modelo de referência e da digitalização intra-oral, respectivamente. A precisão das impressões digitais intra-orais apresenta melhores resultados do que as impressões convencionais em desdentações parciais com pequenas áreas edêntulas. Conclusão: Dentro das limitações deste estudo, podemos verificar que análise da precisão das impressões digitais apresentou melhores resultados do que os modelos de referência digitalizados em desdentados parciais com pequenas áreas êdentulas. Neste estudo piloto verificou-se que a precisão da técnica de impressão digital é influenciada pelas condições da cavidade oral e pelo tipo de substrato digitalizado, já as diferenças na exatidão podem atribuir-se à mudança dimensional do alginato e distorção dos modelos de referência. A análise da exatidão da técnica de impressão convencional é influenciada pelos problemas intrínsecos à mesma e por não terem sido utilizados pontos de referência precisos para efetuar as medições.Introduction: The introduction of CAD/CAM technology allows the use of STL files obtained by an intraoral camera for production of fixed and removable prostheses, without sending cast stone models or conventional intraoral impressions in silicone or alginate to the laboratory.Materials and Methods: A literature review was carried out through the search engine: Pubmed, using the combinations of key-words and Boolean connectors: “removable dentures” OR “removable prostheses” AND (“digital impression technique” OR “CAD-CAM”) NOT “fixed prostheses” and then a second literature review was carried out through the search engines: PubMed, Web of ScienceTM, B-On, ClinicalKey® and ScienceDirect, using the combination:“CAD/CAM” AND “Intraoral digital impression” AND “Prosthodontic”. A clinical pilot study was performed with 3 patients, each patient had two conventional impressions in alginate and two intraoral digital impressions done with the Cerec Omnicam scanner (Dentsply Sirona, Wals, Austria), by the same operator; posteriorly, two stone cast models were also scanned. The two scans of the digital impressions were overlapped as were the two scans the stone cast models and analyzed in the Cerec inLab SW 15.0 software (Sirona Dental Systems, Wals, Austria). Results: In the literature review, we obtained 35 articles in the PubMed. After reading title, abstract and applying the inclusion criteria, we selected 4 articles. Through search engine ClinicalKey®, Web of ScienceTM, B-On and ScienceDirect were selected 14 articles and 5 articles by manual cross reference, staying with 23 articles. In the images analysis, linear measurements, horizontal and vertical were obtained, to verify trueness and precision, respectively. The trueness varied in mean 0.31mm and 0.49mm between the reference model and the virtual models obtained by the scan of the reference model and the intraoral scan, respectively. The precision of intraoral digital impressions are better than conventional impressions in partial edentulous jaws with small edentulous areas. Conclusion: Within the limitations of this study, we can verify that the precision analysis of intraoral scans was better than the scans of reference model in partial edentulous jaws with small edentulous areas. In this pilot study we verified that the precision of digital impression technique is influenced by the oral cavity conditions and by substrate scanning and the differences in the trueness can be attributed to the dimensional change of the alginate and distortion of the reference models. The trueness analysis of the conventional impression technique was influenced by intrinsic problems and the fact that precise reference points for measurements were not used.2017-07-19info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10316/81980http://hdl.handle.net/10316/81980TID:201985489engSousa, Vera Lúcia Azevedo deinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2019-06-02T13:53:27Zoai:estudogeral.uc.pt:10316/81980Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:03:58.593994Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Accuracy of intraoral digital impressions and conventional impressions: at the level of partial removable prostheses.
Precisão das impressões intra-orais digitais e convencionais: ao nível da prótese removível
title Accuracy of intraoral digital impressions and conventional impressions: at the level of partial removable prostheses.
spellingShingle Accuracy of intraoral digital impressions and conventional impressions: at the level of partial removable prostheses.
Sousa, Vera Lúcia Azevedo de
impressão intra-oral digital
impressão convencional
prótese parcial removível
Cerec inLab SW15.0
Cerec Omnicam
intraoral digital impression
conventional impression
partial removable prostheses
Cerec Omnicam
Cerec inLab SW 15.0
title_short Accuracy of intraoral digital impressions and conventional impressions: at the level of partial removable prostheses.
title_full Accuracy of intraoral digital impressions and conventional impressions: at the level of partial removable prostheses.
title_fullStr Accuracy of intraoral digital impressions and conventional impressions: at the level of partial removable prostheses.
title_full_unstemmed Accuracy of intraoral digital impressions and conventional impressions: at the level of partial removable prostheses.
title_sort Accuracy of intraoral digital impressions and conventional impressions: at the level of partial removable prostheses.
author Sousa, Vera Lúcia Azevedo de
author_facet Sousa, Vera Lúcia Azevedo de
author_role author
dc.contributor.author.fl_str_mv Sousa, Vera Lúcia Azevedo de
dc.subject.por.fl_str_mv impressão intra-oral digital
impressão convencional
prótese parcial removível
Cerec inLab SW15.0
Cerec Omnicam
intraoral digital impression
conventional impression
partial removable prostheses
Cerec Omnicam
Cerec inLab SW 15.0
topic impressão intra-oral digital
impressão convencional
prótese parcial removível
Cerec inLab SW15.0
Cerec Omnicam
intraoral digital impression
conventional impression
partial removable prostheses
Cerec Omnicam
Cerec inLab SW 15.0
description Trabalho de Projeto do Mestrado Integrado em Medicina Dentária apresentado à Faculdade de Medicina
publishDate 2017
dc.date.none.fl_str_mv 2017-07-19
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/81980
http://hdl.handle.net/10316/81980
TID:201985489
url http://hdl.handle.net/10316/81980
identifier_str_mv TID:201985489
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133932903464960