Metamaterial vivaldi antenna array for breast cancer detection
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://hdl.handle.net/1822/79895 |
Resumo: | The objective of this work is the design and validation of a directional Vivaldi antenna to detect tumor cells’ electromagnetic waves with a frequency of around 5 GHz. The proposed antenna is 33% smaller than a traditional Vivaldi antenna due to the use of metamaterials in its design. It has an excellent return loss of 25 dB at 5 GHz and adequate radiation characteristics as its gain is 6.2 dB at 5 GHz. The unit cell size of the proposed metamaterial is 0.058λ × 0.054λ at the operation frequency of 5 GHz. The proposed antenna was designed and optimized in CST microwave software, and the measured and simulated results were in good agreement. The experimental study demonstrates that an array composed with the presented antennas can detect the existence of tumors in a liquid breast phantom with positional accuracy through the analysis of the minimum amplitude of S<sub>ii</sub>. |
id |
RCAP_9290c2b6f00933f17b299330080d4d76 |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/79895 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Metamaterial vivaldi antenna array for breast cancer detectiontumor detectionmetamaterial (MTM)antipodal Vivaldi antenna (AVA)antenna arraybreast phantomEngenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e InformáticaEngenharia e Tecnologia::Engenharia MédicaScience & TechnologyThe objective of this work is the design and validation of a directional Vivaldi antenna to detect tumor cells’ electromagnetic waves with a frequency of around 5 GHz. The proposed antenna is 33% smaller than a traditional Vivaldi antenna due to the use of metamaterials in its design. It has an excellent return loss of 25 dB at 5 GHz and adequate radiation characteristics as its gain is 6.2 dB at 5 GHz. The unit cell size of the proposed metamaterial is 0.058λ × 0.054λ at the operation frequency of 5 GHz. The proposed antenna was designed and optimized in CST microwave software, and the measured and simulated results were in good agreement. The experimental study demonstrates that an array composed with the presented antennas can detect the existence of tumors in a liquid breast phantom with positional accuracy through the analysis of the minimum amplitude of S<sub>ii</sub>.FCT national funds, under the national support to R&D units grant, through the reference project UIDB/04436/2020 and UIDP/04436/2020Multidisciplinary Digital Publishing InstituteUniversidade do MinhoSlimi, MarwaJmai, BassemDinis, HugoGharsallah, AliMendes, P. M.2022-05-232022-05-23T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/1822/79895engSlimi, M.; Jmai, B.; Dinis, H.; Gharsallah, A.; Mendes, P.M. Metamaterial Vivaldi Antenna Array for Breast Cancer Detection. Sensors 2022, 22, 3945. https://doi.org/10.3390/s221039451424-82201424-822010.3390/s2210394535632355https://www.mdpi.com/1424-8220/22/10/3945info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-05-11T07:16:30Zoai:repositorium.sdum.uminho.pt:1822/79895Portal AgregadorONGhttps://www.rcaap.pt/oai/openairemluisa.alvim@gmail.comopendoar:71602024-05-11T07:16:30Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Metamaterial vivaldi antenna array for breast cancer detection |
title |
Metamaterial vivaldi antenna array for breast cancer detection |
spellingShingle |
Metamaterial vivaldi antenna array for breast cancer detection Slimi, Marwa tumor detection metamaterial (MTM) antipodal Vivaldi antenna (AVA) antenna array breast phantom Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática Engenharia e Tecnologia::Engenharia Médica Science & Technology |
title_short |
Metamaterial vivaldi antenna array for breast cancer detection |
title_full |
Metamaterial vivaldi antenna array for breast cancer detection |
title_fullStr |
Metamaterial vivaldi antenna array for breast cancer detection |
title_full_unstemmed |
Metamaterial vivaldi antenna array for breast cancer detection |
title_sort |
Metamaterial vivaldi antenna array for breast cancer detection |
author |
Slimi, Marwa |
author_facet |
Slimi, Marwa Jmai, Bassem Dinis, Hugo Gharsallah, Ali Mendes, P. M. |
author_role |
author |
author2 |
Jmai, Bassem Dinis, Hugo Gharsallah, Ali Mendes, P. M. |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Slimi, Marwa Jmai, Bassem Dinis, Hugo Gharsallah, Ali Mendes, P. M. |
dc.subject.por.fl_str_mv |
tumor detection metamaterial (MTM) antipodal Vivaldi antenna (AVA) antenna array breast phantom Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática Engenharia e Tecnologia::Engenharia Médica Science & Technology |
topic |
tumor detection metamaterial (MTM) antipodal Vivaldi antenna (AVA) antenna array breast phantom Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática Engenharia e Tecnologia::Engenharia Médica Science & Technology |
description |
The objective of this work is the design and validation of a directional Vivaldi antenna to detect tumor cells’ electromagnetic waves with a frequency of around 5 GHz. The proposed antenna is 33% smaller than a traditional Vivaldi antenna due to the use of metamaterials in its design. It has an excellent return loss of 25 dB at 5 GHz and adequate radiation characteristics as its gain is 6.2 dB at 5 GHz. The unit cell size of the proposed metamaterial is 0.058λ × 0.054λ at the operation frequency of 5 GHz. The proposed antenna was designed and optimized in CST microwave software, and the measured and simulated results were in good agreement. The experimental study demonstrates that an array composed with the presented antennas can detect the existence of tumors in a liquid breast phantom with positional accuracy through the analysis of the minimum amplitude of S<sub>ii</sub>. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-05-23 2022-05-23T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/1822/79895 |
url |
https://hdl.handle.net/1822/79895 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Slimi, M.; Jmai, B.; Dinis, H.; Gharsallah, A.; Mendes, P.M. Metamaterial Vivaldi Antenna Array for Breast Cancer Detection. Sensors 2022, 22, 3945. https://doi.org/10.3390/s22103945 1424-8220 1424-8220 10.3390/s22103945 35632355 https://www.mdpi.com/1424-8220/22/10/3945 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Multidisciplinary Digital Publishing Institute |
publisher.none.fl_str_mv |
Multidisciplinary Digital Publishing Institute |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
mluisa.alvim@gmail.com |
_version_ |
1817545260765544448 |