Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/73825 |
Resumo: | This work reports the development of a simple and rapid electrochemical immunosensor for the determination of breast cancer biomarker Cancer Antigen 153 (CA153). Disposable and cost-effective chips, consisting of gold screen-printed electrodes (AuSPEs), were used to develop the portable electrochemical devices for monitoring the biomarker in point-of-care (PoC), under clinical context. The biosensor preparation consisted of two simple steps. First, a self-assembled monolayer (SAM) of mercaptosuccinic acid (MSA) was formed at the AuSPE surface. Then, the CA153 antibody was covalently bound to the carboxylic groups standing at the electrode surface using EDC/NHS chemistry. The performance of the developed immunosensor was evaluated by assessing the sensor sensitivity, linear response interval, selectivity and detection limit (LOD). The developed immunosensor provided a wide linear concentration range (from 1.0 to 1000UmL1) and low detection levels were achieved (LOD of 0.95UmL1), enabling the sensitive detection of the cancer biomarker at clinically relevant levels, using square wave voltammetry (SWV) as electroanalytical technique. Moreover, selectivity studies performed against other cancer biomarkers (CA 125 and CA 199) revealed that the antibody has high selectivity for CA15-3 antigen. The immunosensor was applied to the quantification of CA15-3 in artificial serum samples with satisfactory results. |
id |
RCAP_92d03000c327f9ce1fe5f2818efccd4c |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/73825 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-careCA 15-3Cancer biomarkerElectrochemical biosensorImmunosensorScreen-printed electrode (SPE)Point-of-care (PoC) analysisScience & TechnologyThis work reports the development of a simple and rapid electrochemical immunosensor for the determination of breast cancer biomarker Cancer Antigen 153 (CA153). Disposable and cost-effective chips, consisting of gold screen-printed electrodes (AuSPEs), were used to develop the portable electrochemical devices for monitoring the biomarker in point-of-care (PoC), under clinical context. The biosensor preparation consisted of two simple steps. First, a self-assembled monolayer (SAM) of mercaptosuccinic acid (MSA) was formed at the AuSPE surface. Then, the CA153 antibody was covalently bound to the carboxylic groups standing at the electrode surface using EDC/NHS chemistry. The performance of the developed immunosensor was evaluated by assessing the sensor sensitivity, linear response interval, selectivity and detection limit (LOD). The developed immunosensor provided a wide linear concentration range (from 1.0 to 1000UmL1) and low detection levels were achieved (LOD of 0.95UmL1), enabling the sensitive detection of the cancer biomarker at clinically relevant levels, using square wave voltammetry (SWV) as electroanalytical technique. Moreover, selectivity studies performed against other cancer biomarkers (CA 125 and CA 199) revealed that the antibody has high selectivity for CA15-3 antigen. The immunosensor was applied to the quantification of CA15-3 in artificial serum samples with satisfactory results.This research had the financial support of FCT (Fundação para a Ciência e Tecnologia) and co-financed by the European Union (FEDER funds) under the Partnership Agreement PT2020, Research Grants Pest-C/QUI/UIDB/00081/2020 (CIQUP) and NORTE-01-0247-FEDER-017834 (project RamSERS). J.A. Ribeiro (ref. SFRH/BPD/105395/2014) and C.M. Pereira (ref. SFRH/BSAB/150320/2019) acknowledge FCT under the QREN – POPH – Advanced Training, subsidized by European Union and national MEC funds.info:eu-repo/semantics/publishedVersionElsevier BVUniversidade do MinhoRebelo, TâniaRibeiro, JoséSales, M. G. F.Pereira, Carlos M.2021-082021-08-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/73825engRebelo, Tânia; Ribeiro, José; Sales, M. G. F.; Pereira, Carlos M., Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care. Sensing and Bio-Sensing Research, 33(100445), 20212214-180410.1016/j.sbsr.2021.100445https://www.sciencedirect.com/science/article/pii/S2214180421000507info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:45:02Zoai:repositorium.sdum.uminho.pt:1822/73825Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:42:50.477309Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care |
title |
Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care |
spellingShingle |
Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care Rebelo, Tânia CA 15-3 Cancer biomarker Electrochemical biosensor Immunosensor Screen-printed electrode (SPE) Point-of-care (PoC) analysis Science & Technology |
title_short |
Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care |
title_full |
Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care |
title_fullStr |
Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care |
title_full_unstemmed |
Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care |
title_sort |
Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care |
author |
Rebelo, Tânia |
author_facet |
Rebelo, Tânia Ribeiro, José Sales, M. G. F. Pereira, Carlos M. |
author_role |
author |
author2 |
Ribeiro, José Sales, M. G. F. Pereira, Carlos M. |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Rebelo, Tânia Ribeiro, José Sales, M. G. F. Pereira, Carlos M. |
dc.subject.por.fl_str_mv |
CA 15-3 Cancer biomarker Electrochemical biosensor Immunosensor Screen-printed electrode (SPE) Point-of-care (PoC) analysis Science & Technology |
topic |
CA 15-3 Cancer biomarker Electrochemical biosensor Immunosensor Screen-printed electrode (SPE) Point-of-care (PoC) analysis Science & Technology |
description |
This work reports the development of a simple and rapid electrochemical immunosensor for the determination of breast cancer biomarker Cancer Antigen 153 (CA153). Disposable and cost-effective chips, consisting of gold screen-printed electrodes (AuSPEs), were used to develop the portable electrochemical devices for monitoring the biomarker in point-of-care (PoC), under clinical context. The biosensor preparation consisted of two simple steps. First, a self-assembled monolayer (SAM) of mercaptosuccinic acid (MSA) was formed at the AuSPE surface. Then, the CA153 antibody was covalently bound to the carboxylic groups standing at the electrode surface using EDC/NHS chemistry. The performance of the developed immunosensor was evaluated by assessing the sensor sensitivity, linear response interval, selectivity and detection limit (LOD). The developed immunosensor provided a wide linear concentration range (from 1.0 to 1000UmL1) and low detection levels were achieved (LOD of 0.95UmL1), enabling the sensitive detection of the cancer biomarker at clinically relevant levels, using square wave voltammetry (SWV) as electroanalytical technique. Moreover, selectivity studies performed against other cancer biomarkers (CA 125 and CA 199) revealed that the antibody has high selectivity for CA15-3 antigen. The immunosensor was applied to the quantification of CA15-3 in artificial serum samples with satisfactory results. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-08 2021-08-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/73825 |
url |
http://hdl.handle.net/1822/73825 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Rebelo, Tânia; Ribeiro, José; Sales, M. G. F.; Pereira, Carlos M., Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care. Sensing and Bio-Sensing Research, 33(100445), 2021 2214-1804 10.1016/j.sbsr.2021.100445 https://www.sciencedirect.com/science/article/pii/S2214180421000507 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier BV |
publisher.none.fl_str_mv |
Elsevier BV |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132983070818304 |