Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care

Detalhes bibliográficos
Autor(a) principal: Rebelo, Tânia
Data de Publicação: 2021
Outros Autores: Ribeiro, José, Sales, M. G. F., Pereira, Carlos M.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/73825
Resumo: This work reports the development of a simple and rapid electrochemical immunosensor for the determination of breast cancer biomarker Cancer Antigen 153 (CA153). Disposable and cost-effective chips, consisting of gold screen-printed electrodes (AuSPEs), were used to develop the portable electrochemical devices for monitoring the biomarker in point-of-care (PoC), under clinical context. The biosensor preparation consisted of two simple steps. First, a self-assembled monolayer (SAM) of mercaptosuccinic acid (MSA) was formed at the AuSPE surface. Then, the CA153 antibody was covalently bound to the carboxylic groups standing at the electrode surface using EDC/NHS chemistry. The performance of the developed immunosensor was evaluated by assessing the sensor sensitivity, linear response interval, selectivity and detection limit (LOD). The developed immunosensor provided a wide linear concentration range (from 1.0 to 1000UmL1) and low detection levels were achieved (LOD of 0.95UmL1), enabling the sensitive detection of the cancer biomarker at clinically relevant levels, using square wave voltammetry (SWV) as electroanalytical technique. Moreover, selectivity studies performed against other cancer biomarkers (CA 125 and CA 199) revealed that the antibody has high selectivity for CA15-3 antigen. The immunosensor was applied to the quantification of CA15-3 in artificial serum samples with satisfactory results.
id RCAP_92d03000c327f9ce1fe5f2818efccd4c
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/73825
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-careCA 15-3Cancer biomarkerElectrochemical biosensorImmunosensorScreen-printed electrode (SPE)Point-of-care (PoC) analysisScience & TechnologyThis work reports the development of a simple and rapid electrochemical immunosensor for the determination of breast cancer biomarker Cancer Antigen 153 (CA153). Disposable and cost-effective chips, consisting of gold screen-printed electrodes (AuSPEs), were used to develop the portable electrochemical devices for monitoring the biomarker in point-of-care (PoC), under clinical context. The biosensor preparation consisted of two simple steps. First, a self-assembled monolayer (SAM) of mercaptosuccinic acid (MSA) was formed at the AuSPE surface. Then, the CA153 antibody was covalently bound to the carboxylic groups standing at the electrode surface using EDC/NHS chemistry. The performance of the developed immunosensor was evaluated by assessing the sensor sensitivity, linear response interval, selectivity and detection limit (LOD). The developed immunosensor provided a wide linear concentration range (from 1.0 to 1000UmL1) and low detection levels were achieved (LOD of 0.95UmL1), enabling the sensitive detection of the cancer biomarker at clinically relevant levels, using square wave voltammetry (SWV) as electroanalytical technique. Moreover, selectivity studies performed against other cancer biomarkers (CA 125 and CA 199) revealed that the antibody has high selectivity for CA15-3 antigen. The immunosensor was applied to the quantification of CA15-3 in artificial serum samples with satisfactory results.This research had the financial support of FCT (Fundação para a Ciência e Tecnologia) and co-financed by the European Union (FEDER funds) under the Partnership Agreement PT2020, Research Grants Pest-C/QUI/UIDB/00081/2020 (CIQUP) and NORTE-01-0247-FEDER-017834 (project RamSERS). J.A. Ribeiro (ref. SFRH/BPD/105395/2014) and C.M. Pereira (ref. SFRH/BSAB/150320/2019) acknowledge FCT under the QREN – POPH – Advanced Training, subsidized by European Union and national MEC funds.info:eu-repo/semantics/publishedVersionElsevier BVUniversidade do MinhoRebelo, TâniaRibeiro, JoséSales, M. G. F.Pereira, Carlos M.2021-082021-08-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/73825engRebelo, Tânia; Ribeiro, José; Sales, M. G. F.; Pereira, Carlos M., Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care. Sensing and Bio-Sensing Research, 33(100445), 20212214-180410.1016/j.sbsr.2021.100445https://www.sciencedirect.com/science/article/pii/S2214180421000507info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:45:02Zoai:repositorium.sdum.uminho.pt:1822/73825Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:42:50.477309Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care
title Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care
spellingShingle Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care
Rebelo, Tânia
CA 15-3
Cancer biomarker
Electrochemical biosensor
Immunosensor
Screen-printed electrode (SPE)
Point-of-care (PoC) analysis
Science & Technology
title_short Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care
title_full Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care
title_fullStr Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care
title_full_unstemmed Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care
title_sort Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care
author Rebelo, Tânia
author_facet Rebelo, Tânia
Ribeiro, José
Sales, M. G. F.
Pereira, Carlos M.
author_role author
author2 Ribeiro, José
Sales, M. G. F.
Pereira, Carlos M.
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Rebelo, Tânia
Ribeiro, José
Sales, M. G. F.
Pereira, Carlos M.
dc.subject.por.fl_str_mv CA 15-3
Cancer biomarker
Electrochemical biosensor
Immunosensor
Screen-printed electrode (SPE)
Point-of-care (PoC) analysis
Science & Technology
topic CA 15-3
Cancer biomarker
Electrochemical biosensor
Immunosensor
Screen-printed electrode (SPE)
Point-of-care (PoC) analysis
Science & Technology
description This work reports the development of a simple and rapid electrochemical immunosensor for the determination of breast cancer biomarker Cancer Antigen 153 (CA153). Disposable and cost-effective chips, consisting of gold screen-printed electrodes (AuSPEs), were used to develop the portable electrochemical devices for monitoring the biomarker in point-of-care (PoC), under clinical context. The biosensor preparation consisted of two simple steps. First, a self-assembled monolayer (SAM) of mercaptosuccinic acid (MSA) was formed at the AuSPE surface. Then, the CA153 antibody was covalently bound to the carboxylic groups standing at the electrode surface using EDC/NHS chemistry. The performance of the developed immunosensor was evaluated by assessing the sensor sensitivity, linear response interval, selectivity and detection limit (LOD). The developed immunosensor provided a wide linear concentration range (from 1.0 to 1000UmL1) and low detection levels were achieved (LOD of 0.95UmL1), enabling the sensitive detection of the cancer biomarker at clinically relevant levels, using square wave voltammetry (SWV) as electroanalytical technique. Moreover, selectivity studies performed against other cancer biomarkers (CA 125 and CA 199) revealed that the antibody has high selectivity for CA15-3 antigen. The immunosensor was applied to the quantification of CA15-3 in artificial serum samples with satisfactory results.
publishDate 2021
dc.date.none.fl_str_mv 2021-08
2021-08-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/73825
url http://hdl.handle.net/1822/73825
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Rebelo, Tânia; Ribeiro, José; Sales, M. G. F.; Pereira, Carlos M., Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care. Sensing and Bio-Sensing Research, 33(100445), 2021
2214-1804
10.1016/j.sbsr.2021.100445
https://www.sciencedirect.com/science/article/pii/S2214180421000507
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier BV
publisher.none.fl_str_mv Elsevier BV
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132983070818304