Assessment of indoor air quality in geriatric environments of southwestern Europe
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10198/24233 |
Resumo: | The objective of this study was to evaluate physical–chemical and microbial indicators of indoor air quality in three nursing houses (NHs) located in rural areas of the northeast of Portugal. The parameters were measured during two campaigns (winter and summer), twice a day, and in four distinct spaces for spatial variability assessment: dining room, living room, double bedroom and outdoor of the NHs. Physical–chemical indicators were assessed by using a Graywolf IQ 610 probe. Airborne microbial levels were evaluated by direct impaction to the culture media, and subsequently, the microorganisms were identified molecularly. Mean concentrations of physical–chemical (with the exception of total volatile organic compounds, TVOCs) and microbial indicators did not exceed the legal limits. Overall, in all NHs, the indoor-to-outdoor (I/O) concentration ratios of chemical and biological pollutants were ≤ 1 in the summer, while in the winter were > 1. Bacillus, Micrococcus and Staphylococcus were the dominant bacterial genera, and Aspergillus, Cladosporium and Penicillium were the dominant fungal genera. The diversity of species was higher in summer. The main results suggest that a good air quality prevails in all studied spaces, although conditions less desirable have been identified in winter, indicating the need to deepen the study of air quality in these places, since these are occupied by elderly people who are more susceptible to infections. |
id |
RCAP_93a02ad0adef57ea62bbcbff224a633c |
---|---|
oai_identifier_str |
oai:bibliotecadigital.ipb.pt:10198/24233 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Assessment of indoor air quality in geriatric environments of southwestern EuropeBiocontaminantCarbon oxidesIAQIndoor/outdoor ratioNursing homeShannon–Wiener indexThe objective of this study was to evaluate physical–chemical and microbial indicators of indoor air quality in three nursing houses (NHs) located in rural areas of the northeast of Portugal. The parameters were measured during two campaigns (winter and summer), twice a day, and in four distinct spaces for spatial variability assessment: dining room, living room, double bedroom and outdoor of the NHs. Physical–chemical indicators were assessed by using a Graywolf IQ 610 probe. Airborne microbial levels were evaluated by direct impaction to the culture media, and subsequently, the microorganisms were identified molecularly. Mean concentrations of physical–chemical (with the exception of total volatile organic compounds, TVOCs) and microbial indicators did not exceed the legal limits. Overall, in all NHs, the indoor-to-outdoor (I/O) concentration ratios of chemical and biological pollutants were ≤ 1 in the summer, while in the winter were > 1. Bacillus, Micrococcus and Staphylococcus were the dominant bacterial genera, and Aspergillus, Cladosporium and Penicillium were the dominant fungal genera. The diversity of species was higher in summer. The main results suggest that a good air quality prevails in all studied spaces, although conditions less desirable have been identified in winter, indicating the need to deepen the study of air quality in these places, since these are occupied by elderly people who are more susceptible to infections.The authors are grateful to the Foundation for Science and Technology (FCT, Portugal) for financial support by national funds FCT/MCTES to CIMO [UIDB/00690/2020]. The authors would also like to acknowledge Leonardo Furst for the support provided in the elaboration of some figures, as well as all the members of each nursing home team for his unconditional support throughout the study.Biblioteca Digital do IPBPereira, ErmelindaMadacussengua, ObeteBaptista, PaulaFeliciano, Manuel2018-01-19T10:00:00Z20212021-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10198/24233engPereira, Ermelinda; Madacussengua, Obete; Baptista, Paula; Feliciano, Manuel (2021). Assessment of indoor air quality in geriatric environments of southwestern Europe. Aerobiologia. ISSN 0393-5965. 37:1, p. 139-1530393-596510.1007/s10453-020-09681-5info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-21T10:54:09Zoai:bibliotecadigital.ipb.pt:10198/24233Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T23:15:05.190886Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Assessment of indoor air quality in geriatric environments of southwestern Europe |
title |
Assessment of indoor air quality in geriatric environments of southwestern Europe |
spellingShingle |
Assessment of indoor air quality in geriatric environments of southwestern Europe Pereira, Ermelinda Biocontaminant Carbon oxides IAQ Indoor/outdoor ratio Nursing home Shannon–Wiener index |
title_short |
Assessment of indoor air quality in geriatric environments of southwestern Europe |
title_full |
Assessment of indoor air quality in geriatric environments of southwestern Europe |
title_fullStr |
Assessment of indoor air quality in geriatric environments of southwestern Europe |
title_full_unstemmed |
Assessment of indoor air quality in geriatric environments of southwestern Europe |
title_sort |
Assessment of indoor air quality in geriatric environments of southwestern Europe |
author |
Pereira, Ermelinda |
author_facet |
Pereira, Ermelinda Madacussengua, Obete Baptista, Paula Feliciano, Manuel |
author_role |
author |
author2 |
Madacussengua, Obete Baptista, Paula Feliciano, Manuel |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Biblioteca Digital do IPB |
dc.contributor.author.fl_str_mv |
Pereira, Ermelinda Madacussengua, Obete Baptista, Paula Feliciano, Manuel |
dc.subject.por.fl_str_mv |
Biocontaminant Carbon oxides IAQ Indoor/outdoor ratio Nursing home Shannon–Wiener index |
topic |
Biocontaminant Carbon oxides IAQ Indoor/outdoor ratio Nursing home Shannon–Wiener index |
description |
The objective of this study was to evaluate physical–chemical and microbial indicators of indoor air quality in three nursing houses (NHs) located in rural areas of the northeast of Portugal. The parameters were measured during two campaigns (winter and summer), twice a day, and in four distinct spaces for spatial variability assessment: dining room, living room, double bedroom and outdoor of the NHs. Physical–chemical indicators were assessed by using a Graywolf IQ 610 probe. Airborne microbial levels were evaluated by direct impaction to the culture media, and subsequently, the microorganisms were identified molecularly. Mean concentrations of physical–chemical (with the exception of total volatile organic compounds, TVOCs) and microbial indicators did not exceed the legal limits. Overall, in all NHs, the indoor-to-outdoor (I/O) concentration ratios of chemical and biological pollutants were ≤ 1 in the summer, while in the winter were > 1. Bacillus, Micrococcus and Staphylococcus were the dominant bacterial genera, and Aspergillus, Cladosporium and Penicillium were the dominant fungal genera. The diversity of species was higher in summer. The main results suggest that a good air quality prevails in all studied spaces, although conditions less desirable have been identified in winter, indicating the need to deepen the study of air quality in these places, since these are occupied by elderly people who are more susceptible to infections. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-01-19T10:00:00Z 2021 2021-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10198/24233 |
url |
http://hdl.handle.net/10198/24233 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Pereira, Ermelinda; Madacussengua, Obete; Baptista, Paula; Feliciano, Manuel (2021). Assessment of indoor air quality in geriatric environments of southwestern Europe. Aerobiologia. ISSN 0393-5965. 37:1, p. 139-153 0393-5965 10.1007/s10453-020-09681-5 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1817551909992529920 |