Drinking water treatment in a gravimetric flow system with TiO2 coated membranes
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/1822/15110 |
Resumo: | This paper presents filtration results for drinking water treatment obtained with a commercial cellulose acetate membrane of 0.45 μm pore diameter, with and without TiO2 coating. The deposition of titanium dioxide thin films onto membrane surface was made by pulsed-frequency d.c. reactive magnetron sputtering at room temperature from a high purity Ti target in Ar/O2/N2 atmosphere, at different conditions for cathode current and for deposition time. The proposed membranes were used in a filtration system driven by gravitation without the requirement of energy supply. The obtained results showed that the proposed system is able to remove color and turbidity from raw water. Besides, the modified membrane presented better results than the neat one regarding to membrane fouling and chlorine removal. |
id |
RCAP_992286f372a2be29bc1449296e20d1cc |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/15110 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Drinking water treatment in a gravimetric flow system with TiO2 coated membranesDrinking waterMembrane modificationTiO2 filmMembrane foulingTiO film 2Science & TechnologyThis paper presents filtration results for drinking water treatment obtained with a commercial cellulose acetate membrane of 0.45 μm pore diameter, with and without TiO2 coating. The deposition of titanium dioxide thin films onto membrane surface was made by pulsed-frequency d.c. reactive magnetron sputtering at room temperature from a high purity Ti target in Ar/O2/N2 atmosphere, at different conditions for cathode current and for deposition time. The proposed membranes were used in a filtration system driven by gravitation without the requirement of energy supply. The obtained results showed that the proposed system is able to remove color and turbidity from raw water. Besides, the modified membrane presented better results than the neat one regarding to membrane fouling and chlorine removal.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) and Fundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG)ElsevierUniversidade do MinhoBergamasco, RosangêlaSilva, Flávia Vieira daArakawa, Flávia SayuriYamaguchi, YamaguchiReis, Miria Hespanhol MirandaTavares, C. J.Amorim, M. T. Pessoa deTavares, Célia Regina Granhen2011-10-152011-10-15T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/15110eng1385-894710.1016/j.cej.2011.08.056info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:36:51Zoai:repositorium.sdum.uminho.pt:1822/15110Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:33:01.891106Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Drinking water treatment in a gravimetric flow system with TiO2 coated membranes |
title |
Drinking water treatment in a gravimetric flow system with TiO2 coated membranes |
spellingShingle |
Drinking water treatment in a gravimetric flow system with TiO2 coated membranes Bergamasco, Rosangêla Drinking water Membrane modification TiO2 film Membrane fouling TiO film 2 Science & Technology |
title_short |
Drinking water treatment in a gravimetric flow system with TiO2 coated membranes |
title_full |
Drinking water treatment in a gravimetric flow system with TiO2 coated membranes |
title_fullStr |
Drinking water treatment in a gravimetric flow system with TiO2 coated membranes |
title_full_unstemmed |
Drinking water treatment in a gravimetric flow system with TiO2 coated membranes |
title_sort |
Drinking water treatment in a gravimetric flow system with TiO2 coated membranes |
author |
Bergamasco, Rosangêla |
author_facet |
Bergamasco, Rosangêla Silva, Flávia Vieira da Arakawa, Flávia Sayuri Yamaguchi, Yamaguchi Reis, Miria Hespanhol Miranda Tavares, C. J. Amorim, M. T. Pessoa de Tavares, Célia Regina Granhen |
author_role |
author |
author2 |
Silva, Flávia Vieira da Arakawa, Flávia Sayuri Yamaguchi, Yamaguchi Reis, Miria Hespanhol Miranda Tavares, C. J. Amorim, M. T. Pessoa de Tavares, Célia Regina Granhen |
author2_role |
author author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Bergamasco, Rosangêla Silva, Flávia Vieira da Arakawa, Flávia Sayuri Yamaguchi, Yamaguchi Reis, Miria Hespanhol Miranda Tavares, C. J. Amorim, M. T. Pessoa de Tavares, Célia Regina Granhen |
dc.subject.por.fl_str_mv |
Drinking water Membrane modification TiO2 film Membrane fouling TiO film 2 Science & Technology |
topic |
Drinking water Membrane modification TiO2 film Membrane fouling TiO film 2 Science & Technology |
description |
This paper presents filtration results for drinking water treatment obtained with a commercial cellulose acetate membrane of 0.45 μm pore diameter, with and without TiO2 coating. The deposition of titanium dioxide thin films onto membrane surface was made by pulsed-frequency d.c. reactive magnetron sputtering at room temperature from a high purity Ti target in Ar/O2/N2 atmosphere, at different conditions for cathode current and for deposition time. The proposed membranes were used in a filtration system driven by gravitation without the requirement of energy supply. The obtained results showed that the proposed system is able to remove color and turbidity from raw water. Besides, the modified membrane presented better results than the neat one regarding to membrane fouling and chlorine removal. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-10-15 2011-10-15T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/15110 |
url |
http://hdl.handle.net/1822/15110 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
1385-8947 10.1016/j.cej.2011.08.056 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799132846538883072 |