Validation of an HPLC-DAD/UV method for the quantification of cyclamate in tabletop sweeteners: risk of exceeding the acceptable daily intake

Detalhes bibliográficos
Autor(a) principal: Vasco, Elsa
Data de Publicação: 2017
Outros Autores: Sargaço, B., Serra, C.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.18/5269
Resumo: Cyclamate is widely used as intense sweetener in the European Union. The absence of a maximum limit for the use of cyclamate in tabletop sweeteners and the growing demand for this type of product highlights the importance of developing robust analytical methods for the determination of its content to understand if the consumption of tabletop sweeteners can have a negative impact on human health. The present work aimed at the optimisation and validation of an high-performance liquid chromatography (HPLC) analytical method for cyclamate determination in tabletop sweeteners based on the procedure of European Standard EN 12857. The validated method was then applied to the determination of this sweetener in different types of tabletop sweeteners (liquid, powder and tablets). Both standards and samples solutions were submitted to a derivatisation procedure which converted cyclamate to N,N-dichlorocyclohexylamine. The derivatised product was separated and quantified using a reversed-phase column, a mobile phase composed of water (20%) and methanol (80%), isocratic flow of 1 ml min-1, and detection by ultraviolet spectrophotometry at a wavelength of 314 nm. The analytical method was internally validated according to the following validation parameters: working range, linearity, limits of detection and quantification, sensitivity, precision (repeatability and intermediate precision), and uncertainty. This method proved to be specific and selective for the determination of this sweetener, showing repeatability, RSDr ≤ 3%, intermediate precision, RSDR ≤ 3.3%, and recovery rates from 92% to 108% for the different tabletop sweeteners. The method uncertainty was 9.4%. The concentration of cyclamate in the samples varied significantly, from 2.9% to 73.9%, which demonstrated that a possible excessive consumption of one of the analysed sweeteners can lead to exceeding the acceptable daily intake for cyclamate.
id RCAP_9dff239876c6553f69aeac5e71eeaee8
oai_identifier_str oai:repositorio.insa.pt:10400.18/5269
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Validation of an HPLC-DAD/UV method for the quantification of cyclamate in tabletop sweeteners: risk of exceeding the acceptable daily intakeCyclamateADIHPLCtabletop SweetenersQuantificationValidationDaily intakeComposição de AlimentosCyclamate is widely used as intense sweetener in the European Union. The absence of a maximum limit for the use of cyclamate in tabletop sweeteners and the growing demand for this type of product highlights the importance of developing robust analytical methods for the determination of its content to understand if the consumption of tabletop sweeteners can have a negative impact on human health. The present work aimed at the optimisation and validation of an high-performance liquid chromatography (HPLC) analytical method for cyclamate determination in tabletop sweeteners based on the procedure of European Standard EN 12857. The validated method was then applied to the determination of this sweetener in different types of tabletop sweeteners (liquid, powder and tablets). Both standards and samples solutions were submitted to a derivatisation procedure which converted cyclamate to N,N-dichlorocyclohexylamine. The derivatised product was separated and quantified using a reversed-phase column, a mobile phase composed of water (20%) and methanol (80%), isocratic flow of 1 ml min-1, and detection by ultraviolet spectrophotometry at a wavelength of 314 nm. The analytical method was internally validated according to the following validation parameters: working range, linearity, limits of detection and quantification, sensitivity, precision (repeatability and intermediate precision), and uncertainty. This method proved to be specific and selective for the determination of this sweetener, showing repeatability, RSDr ≤ 3%, intermediate precision, RSDR ≤ 3.3%, and recovery rates from 92% to 108% for the different tabletop sweeteners. The method uncertainty was 9.4%. The concentration of cyclamate in the samples varied significantly, from 2.9% to 73.9%, which demonstrated that a possible excessive consumption of one of the analysed sweeteners can lead to exceeding the acceptable daily intake for cyclamate.Taylor & FrancisRepositório Científico do Instituto Nacional de SaúdeVasco, ElsaSargaço, B.Serra, C.2018-03-06T19:32:29Z2017-062017-06-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.18/5269engFood Addit Contam Part A: Chem Anal Control Expo Risk Assess. 2017 Jun;34(6):883-890. doi: 10.1080/19440049.2017.1306756. Epub 2017 Apr 11.1944-0049 (print)10.1080/19440049.2017.1306756info:eu-repo/semantics/embargoedAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-20T15:40:46Zoai:repositorio.insa.pt:10400.18/5269Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:39:58.601859Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Validation of an HPLC-DAD/UV method for the quantification of cyclamate in tabletop sweeteners: risk of exceeding the acceptable daily intake
title Validation of an HPLC-DAD/UV method for the quantification of cyclamate in tabletop sweeteners: risk of exceeding the acceptable daily intake
spellingShingle Validation of an HPLC-DAD/UV method for the quantification of cyclamate in tabletop sweeteners: risk of exceeding the acceptable daily intake
Vasco, Elsa
Cyclamate
ADI
HPLC
tabletop Sweeteners
Quantification
Validation
Daily intake
Composição de Alimentos
title_short Validation of an HPLC-DAD/UV method for the quantification of cyclamate in tabletop sweeteners: risk of exceeding the acceptable daily intake
title_full Validation of an HPLC-DAD/UV method for the quantification of cyclamate in tabletop sweeteners: risk of exceeding the acceptable daily intake
title_fullStr Validation of an HPLC-DAD/UV method for the quantification of cyclamate in tabletop sweeteners: risk of exceeding the acceptable daily intake
title_full_unstemmed Validation of an HPLC-DAD/UV method for the quantification of cyclamate in tabletop sweeteners: risk of exceeding the acceptable daily intake
title_sort Validation of an HPLC-DAD/UV method for the quantification of cyclamate in tabletop sweeteners: risk of exceeding the acceptable daily intake
author Vasco, Elsa
author_facet Vasco, Elsa
Sargaço, B.
Serra, C.
author_role author
author2 Sargaço, B.
Serra, C.
author2_role author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Nacional de Saúde
dc.contributor.author.fl_str_mv Vasco, Elsa
Sargaço, B.
Serra, C.
dc.subject.por.fl_str_mv Cyclamate
ADI
HPLC
tabletop Sweeteners
Quantification
Validation
Daily intake
Composição de Alimentos
topic Cyclamate
ADI
HPLC
tabletop Sweeteners
Quantification
Validation
Daily intake
Composição de Alimentos
description Cyclamate is widely used as intense sweetener in the European Union. The absence of a maximum limit for the use of cyclamate in tabletop sweeteners and the growing demand for this type of product highlights the importance of developing robust analytical methods for the determination of its content to understand if the consumption of tabletop sweeteners can have a negative impact on human health. The present work aimed at the optimisation and validation of an high-performance liquid chromatography (HPLC) analytical method for cyclamate determination in tabletop sweeteners based on the procedure of European Standard EN 12857. The validated method was then applied to the determination of this sweetener in different types of tabletop sweeteners (liquid, powder and tablets). Both standards and samples solutions were submitted to a derivatisation procedure which converted cyclamate to N,N-dichlorocyclohexylamine. The derivatised product was separated and quantified using a reversed-phase column, a mobile phase composed of water (20%) and methanol (80%), isocratic flow of 1 ml min-1, and detection by ultraviolet spectrophotometry at a wavelength of 314 nm. The analytical method was internally validated according to the following validation parameters: working range, linearity, limits of detection and quantification, sensitivity, precision (repeatability and intermediate precision), and uncertainty. This method proved to be specific and selective for the determination of this sweetener, showing repeatability, RSDr ≤ 3%, intermediate precision, RSDR ≤ 3.3%, and recovery rates from 92% to 108% for the different tabletop sweeteners. The method uncertainty was 9.4%. The concentration of cyclamate in the samples varied significantly, from 2.9% to 73.9%, which demonstrated that a possible excessive consumption of one of the analysed sweeteners can lead to exceeding the acceptable daily intake for cyclamate.
publishDate 2017
dc.date.none.fl_str_mv 2017-06
2017-06-01T00:00:00Z
2018-03-06T19:32:29Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.18/5269
url http://hdl.handle.net/10400.18/5269
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Food Addit Contam Part A: Chem Anal Control Expo Risk Assess. 2017 Jun;34(6):883-890. doi: 10.1080/19440049.2017.1306756. Epub 2017 Apr 11.
1944-0049 (print)
10.1080/19440049.2017.1306756
dc.rights.driver.fl_str_mv info:eu-repo/semantics/embargoedAccess
eu_rights_str_mv embargoedAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Taylor & Francis
publisher.none.fl_str_mv Taylor & Francis
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132141046464512