A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.19/4076 |
Resumo: | Adequate airtightness levels are fundamental for the indoor environmental quality and energy efficiency of buildings. The quantitative characterization of expected leaks of common building elements is useful for practitioners that intend to improve building enclosures for airtightness optimization. This study intends to contribute to the quantification of the permeability of windows with a focus on the Southern European context of low airtightness in heavy construction buildings, where windows play an important role. A large experimental investigation was therefore carried out in 23 spaces, establishing three possible set-ups (nothing sealed, window sealed and window and roller-shutter sealed), using the fan pressurization method. A total of 104 tests were performed. Results revealed that the windows’ permeability indices ranged from 4.8 to 96.4 m3/(h m2) and from 1.2 to 30.8 m3/(h m), with average values of 28.7 m3/(h m2) and 8.9 m3/(h m), the roller-shutter contribution can be highly variable; also the year of construction, the frame material and the opening system are the key parameters for the airtightness of windows |
id |
RCAP_9e1ba4c91e7f71f61d1b87383d73172c |
---|---|
oai_identifier_str |
oai:repositorio.ipv.pt:10400.19/4076 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
A contribution for the quantification of the influence of windows on the airtightness of Southern European buildingsWindowsAirtightnessLeakagePermeabilityRoller-shutterBlower doorAdequate airtightness levels are fundamental for the indoor environmental quality and energy efficiency of buildings. The quantitative characterization of expected leaks of common building elements is useful for practitioners that intend to improve building enclosures for airtightness optimization. This study intends to contribute to the quantification of the permeability of windows with a focus on the Southern European context of low airtightness in heavy construction buildings, where windows play an important role. A large experimental investigation was therefore carried out in 23 spaces, establishing three possible set-ups (nothing sealed, window sealed and window and roller-shutter sealed), using the fan pressurization method. A total of 104 tests were performed. Results revealed that the windows’ permeability indices ranged from 4.8 to 96.4 m3/(h m2) and from 1.2 to 30.8 m3/(h m), with average values of 28.7 m3/(h m2) and 8.9 m3/(h m), the roller-shutter contribution can be highly variable; also the year of construction, the frame material and the opening system are the key parameters for the airtightness of windowsElsevierRepositório Científico do Instituto Politécnico de ViseuAlmeida, RicardoRamos, Nuno M.M.Pereira, Pedro F.2017-01-23T10:02:13Z20172017-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.19/4076engAlmeida, R. M. S. F., Ramos, N. M. M., & Pereira, P. F. (2017). A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings. Energy and Buildings, 139, 174–185.10.1016/j.enbuild.2017.01.012metadata only accessinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-01-16T15:27:01Zoai:repositorio.ipv.pt:10400.19/4076Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:42:46.824576Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings |
title |
A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings |
spellingShingle |
A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings Almeida, Ricardo Windows Airtightness Leakage Permeability Roller-shutter Blower door |
title_short |
A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings |
title_full |
A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings |
title_fullStr |
A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings |
title_full_unstemmed |
A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings |
title_sort |
A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings |
author |
Almeida, Ricardo |
author_facet |
Almeida, Ricardo Ramos, Nuno M.M. Pereira, Pedro F. |
author_role |
author |
author2 |
Ramos, Nuno M.M. Pereira, Pedro F. |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Repositório Científico do Instituto Politécnico de Viseu |
dc.contributor.author.fl_str_mv |
Almeida, Ricardo Ramos, Nuno M.M. Pereira, Pedro F. |
dc.subject.por.fl_str_mv |
Windows Airtightness Leakage Permeability Roller-shutter Blower door |
topic |
Windows Airtightness Leakage Permeability Roller-shutter Blower door |
description |
Adequate airtightness levels are fundamental for the indoor environmental quality and energy efficiency of buildings. The quantitative characterization of expected leaks of common building elements is useful for practitioners that intend to improve building enclosures for airtightness optimization. This study intends to contribute to the quantification of the permeability of windows with a focus on the Southern European context of low airtightness in heavy construction buildings, where windows play an important role. A large experimental investigation was therefore carried out in 23 spaces, establishing three possible set-ups (nothing sealed, window sealed and window and roller-shutter sealed), using the fan pressurization method. A total of 104 tests were performed. Results revealed that the windows’ permeability indices ranged from 4.8 to 96.4 m3/(h m2) and from 1.2 to 30.8 m3/(h m), with average values of 28.7 m3/(h m2) and 8.9 m3/(h m), the roller-shutter contribution can be highly variable; also the year of construction, the frame material and the opening system are the key parameters for the airtightness of windows |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-01-23T10:02:13Z 2017 2017-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.19/4076 |
url |
http://hdl.handle.net/10400.19/4076 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Almeida, R. M. S. F., Ramos, N. M. M., & Pereira, P. F. (2017). A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings. Energy and Buildings, 139, 174–185. 10.1016/j.enbuild.2017.01.012 |
dc.rights.driver.fl_str_mv |
metadata only access info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
metadata only access |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799130895388508160 |