A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings

Detalhes bibliográficos
Autor(a) principal: Almeida, Ricardo
Data de Publicação: 2017
Outros Autores: Ramos, Nuno M.M., Pereira, Pedro F.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.19/4076
Resumo: Adequate airtightness levels are fundamental for the indoor environmental quality and energy efficiency of buildings. The quantitative characterization of expected leaks of common building elements is useful for practitioners that intend to improve building enclosures for airtightness optimization. This study intends to contribute to the quantification of the permeability of windows with a focus on the Southern European context of low airtightness in heavy construction buildings, where windows play an important role. A large experimental investigation was therefore carried out in 23 spaces, establishing three possible set-ups (nothing sealed, window sealed and window and roller-shutter sealed), using the fan pressurization method. A total of 104 tests were performed. Results revealed that the windows’ permeability indices ranged from 4.8 to 96.4 m3/(h m2) and from 1.2 to 30.8 m3/(h m), with average values of 28.7 m3/(h m2) and 8.9 m3/(h m), the roller-shutter contribution can be highly variable; also the year of construction, the frame material and the opening system are the key parameters for the airtightness of windows
id RCAP_9e1ba4c91e7f71f61d1b87383d73172c
oai_identifier_str oai:repositorio.ipv.pt:10400.19/4076
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling A contribution for the quantification of the influence of windows on the airtightness of Southern European buildingsWindowsAirtightnessLeakagePermeabilityRoller-shutterBlower doorAdequate airtightness levels are fundamental for the indoor environmental quality and energy efficiency of buildings. The quantitative characterization of expected leaks of common building elements is useful for practitioners that intend to improve building enclosures for airtightness optimization. This study intends to contribute to the quantification of the permeability of windows with a focus on the Southern European context of low airtightness in heavy construction buildings, where windows play an important role. A large experimental investigation was therefore carried out in 23 spaces, establishing three possible set-ups (nothing sealed, window sealed and window and roller-shutter sealed), using the fan pressurization method. A total of 104 tests were performed. Results revealed that the windows’ permeability indices ranged from 4.8 to 96.4 m3/(h m2) and from 1.2 to 30.8 m3/(h m), with average values of 28.7 m3/(h m2) and 8.9 m3/(h m), the roller-shutter contribution can be highly variable; also the year of construction, the frame material and the opening system are the key parameters for the airtightness of windowsElsevierRepositório Científico do Instituto Politécnico de ViseuAlmeida, RicardoRamos, Nuno M.M.Pereira, Pedro F.2017-01-23T10:02:13Z20172017-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.19/4076engAlmeida, R. M. S. F., Ramos, N. M. M., & Pereira, P. F. (2017). A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings. Energy and Buildings, 139, 174–185.10.1016/j.enbuild.2017.01.012metadata only accessinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-01-16T15:27:01Zoai:repositorio.ipv.pt:10400.19/4076Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:42:46.824576Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings
title A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings
spellingShingle A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings
Almeida, Ricardo
Windows
Airtightness
Leakage
Permeability
Roller-shutter
Blower door
title_short A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings
title_full A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings
title_fullStr A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings
title_full_unstemmed A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings
title_sort A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings
author Almeida, Ricardo
author_facet Almeida, Ricardo
Ramos, Nuno M.M.
Pereira, Pedro F.
author_role author
author2 Ramos, Nuno M.M.
Pereira, Pedro F.
author2_role author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Politécnico de Viseu
dc.contributor.author.fl_str_mv Almeida, Ricardo
Ramos, Nuno M.M.
Pereira, Pedro F.
dc.subject.por.fl_str_mv Windows
Airtightness
Leakage
Permeability
Roller-shutter
Blower door
topic Windows
Airtightness
Leakage
Permeability
Roller-shutter
Blower door
description Adequate airtightness levels are fundamental for the indoor environmental quality and energy efficiency of buildings. The quantitative characterization of expected leaks of common building elements is useful for practitioners that intend to improve building enclosures for airtightness optimization. This study intends to contribute to the quantification of the permeability of windows with a focus on the Southern European context of low airtightness in heavy construction buildings, where windows play an important role. A large experimental investigation was therefore carried out in 23 spaces, establishing three possible set-ups (nothing sealed, window sealed and window and roller-shutter sealed), using the fan pressurization method. A total of 104 tests were performed. Results revealed that the windows’ permeability indices ranged from 4.8 to 96.4 m3/(h m2) and from 1.2 to 30.8 m3/(h m), with average values of 28.7 m3/(h m2) and 8.9 m3/(h m), the roller-shutter contribution can be highly variable; also the year of construction, the frame material and the opening system are the key parameters for the airtightness of windows
publishDate 2017
dc.date.none.fl_str_mv 2017-01-23T10:02:13Z
2017
2017-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.19/4076
url http://hdl.handle.net/10400.19/4076
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Almeida, R. M. S. F., Ramos, N. M. M., & Pereira, P. F. (2017). A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings. Energy and Buildings, 139, 174–185.
10.1016/j.enbuild.2017.01.012
dc.rights.driver.fl_str_mv metadata only access
info:eu-repo/semantics/openAccess
rights_invalid_str_mv metadata only access
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130895388508160