Ergonomia aplicada ao desenvolvimento de palmilhas para calçado de proteção

Detalhes bibliográficos
Autor(a) principal: Lima, Ana Lúcia Gadelha de Moura
Data de Publicação: 2022
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://hdl.handle.net/1822/79697
Resumo: Dissertação de mestrado em Engenharia Humana
id RCAP_9eacfd43cd927e77a8d9946fb4d7b83c
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/79697
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Ergonomia aplicada ao desenvolvimento de palmilhas para calçado de proteçãoErgonomics applied to the development of insoles for protective footwearAnálise de marchaErgonomia, palmilhasPressão plantarErgonomicsGait analysisInsolesPlantar pressureEngenharia e Tecnologia::Outras Engenharias e TecnologiasDissertação de mestrado em Engenharia HumanaA participação da Ergonomia e Fatores Humanos tem uma importante função no design de calçados de segurança e palmilhas, proporcionando não apenas proteção dos pés contra lesões de impacto e compressão, mas também conforto e estabilidade, de modo que não afete a dinâmica da marcha do usuário. A vista disso, o presente estudo teve como objetivo analisar os efeitos da utilização de uma nova palmilha para calçados de proteção, em termos de pressão plantar, através da medição com plataforma de pressões e analisar a cinemática do padrão de marcha utilizando o protocolo do Oxford Foot Model através do sistema optométrico tridimensional Vicon Motion Capture System, em comparação com a palmilha anteriormente utilizada. O presente trabalho foi realizado em laboratório, com uma amostra de 25 participantes. Os ensaios foram executados comparando os ambientes com a palmilha standard e com a palmilha inovadora nos três rockers da marcha, representados pelo calcanhar, mediopé e antepé, no pé direito e no pé esquerdo separadamente, de acordo com a classificação do tipo de pé do participante. Na pressão plantar, foi analisada a distribuição da pressão plantar total e máxima. Na análise biomecânica da marcha foram comparadas as cincos variáveis medidas da cinemática do tornozelo e articulações intrínsecas dos pés esquerdo e direito para cada sujeito, em termos de correlação, amplitude de movimento e coeficiente de variação. Um indicador de conforto e eficácia da palmilha é a melhora da distribuição da pressão plantar sem nenhum custo cinemático associado. Os resultados apontaram que a palmilha inovadora apresentou uma melhor distribuição nomeadamente em termos de pressão plantar máxima nas regiões do antepé e retropé, associadas aos eventos de rocker de calcanhar e de antepé, importantes nas fases de receção da carga (retropé) e de propulsão (antepé). Na análise biomecânica da marcha constatou-se que não houve variação na mecânica normal do pé em nenhum dos três ambientes analisados (descalço, palmilha standard e palmilha inovadora). A articulação do hálux foi a que apresentou maiores divergências com o pé descalço, no que diz respeito à amplitude de movimento e variabilidade.The participation of Ergonomics and Human Factors fulfil an important role in the design of safety shoes and insoles, providing not only protection of the feet against impact and compaction injuries, but also comfort and stability, so that it does not affect the user's gait dynamics. In view of this, the present study aimed to analyse the effects of using a new insole for protective shoes, in terms of plantar pressure, through the measurement with a pressure platform and to analyse a kinematics of the gait pattern using the Oxford Foot Model protocol through the three-dimensional optometric system Vicon Motion Capture System, compared to a previously used insole. The present work was carried out in the laboratory, with a sample of 25 participants. The tests were performed comparing the environments with the insole standard insole and the innovative insole on the three rockers of the gait, represented by the heel, midfoot and forefoot, on the right and left foot separately, according to the classification of the participant's foot type. In plantar pressure, the distribution of total and maximum plantar pressure was analysed. In the biomechanical analysis of gait, the five measured variables of ankle kinematics and intrinsic joints of the left and right feet were compared for each subject, in terms of correlation, range of motion and coefficient of variation. An indicator of the comfort and effectiveness of the insole is improved plantar pressure distribution with no associated kinematic cost. The results demonstrate that the innovative insole presented a better distribution, namely in terms of maximum plantar pressure in the forefoot and hindfoot regions, associated with the heel and forefoot rocker events, important in the load reception (hindfoot) and propulsion phases (forefoot). In the biomechanical analysis of gait, it was found that there was no variation in the normal mechanics of the foot in any of the three environments analyzed (barefoot, standard insole and innovative insole). The hallux joint was the one that presented the greatest divergences with the bare foot, in terms of amplitude and variability.Costa, Nélson Bruno Martins Marques daCosta, Susana Raquel PintoUniversidade do MinhoLima, Ana Lúcia Gadelha de Moura2022-02-212022-02-21T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttps://hdl.handle.net/1822/79697por203004256info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-04T01:16:57Zoai:repositorium.sdum.uminho.pt:1822/79697Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:55:23.663306Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Ergonomia aplicada ao desenvolvimento de palmilhas para calçado de proteção
Ergonomics applied to the development of insoles for protective footwear
title Ergonomia aplicada ao desenvolvimento de palmilhas para calçado de proteção
spellingShingle Ergonomia aplicada ao desenvolvimento de palmilhas para calçado de proteção
Lima, Ana Lúcia Gadelha de Moura
Análise de marcha
Ergonomia, palmilhas
Pressão plantar
Ergonomics
Gait analysis
Insoles
Plantar pressure
Engenharia e Tecnologia::Outras Engenharias e Tecnologias
title_short Ergonomia aplicada ao desenvolvimento de palmilhas para calçado de proteção
title_full Ergonomia aplicada ao desenvolvimento de palmilhas para calçado de proteção
title_fullStr Ergonomia aplicada ao desenvolvimento de palmilhas para calçado de proteção
title_full_unstemmed Ergonomia aplicada ao desenvolvimento de palmilhas para calçado de proteção
title_sort Ergonomia aplicada ao desenvolvimento de palmilhas para calçado de proteção
author Lima, Ana Lúcia Gadelha de Moura
author_facet Lima, Ana Lúcia Gadelha de Moura
author_role author
dc.contributor.none.fl_str_mv Costa, Nélson Bruno Martins Marques da
Costa, Susana Raquel Pinto
Universidade do Minho
dc.contributor.author.fl_str_mv Lima, Ana Lúcia Gadelha de Moura
dc.subject.por.fl_str_mv Análise de marcha
Ergonomia, palmilhas
Pressão plantar
Ergonomics
Gait analysis
Insoles
Plantar pressure
Engenharia e Tecnologia::Outras Engenharias e Tecnologias
topic Análise de marcha
Ergonomia, palmilhas
Pressão plantar
Ergonomics
Gait analysis
Insoles
Plantar pressure
Engenharia e Tecnologia::Outras Engenharias e Tecnologias
description Dissertação de mestrado em Engenharia Humana
publishDate 2022
dc.date.none.fl_str_mv 2022-02-21
2022-02-21T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/79697
url https://hdl.handle.net/1822/79697
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv 203004256
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132338782732288