The performance of Plusoptix A09 in detection of Refractive Amblyopia Risk Factors

Detalhes bibliográficos
Autor(a) principal: Lemos, José Alberto
Data de Publicação: 2016
Outros Autores: Gonçalves, Rita, Ribeiro, Isabel, Mota, Ágata, Mateus, Catarina, Vieira, Bruna, Tenedório, Paula
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://doi.org/10.48560/rspo.7537
Resumo: Purpose: To assess the accuracy of the Plusoptix A09 noncycloplegic photorefraction for detection of refractive amblyopia risk factors (RARFs) in children and determine cutoff points. Methods: This study included 402 children observed in Pediatric Ophthalmology Clinic between June and December 2014. All children underwent initially photorefraction using Plusoptix A09 followed by cycloplegic retinoscopy (obtained during a complete ophthalmologic examination). Patients were considered to have RARFs based on American Association for Pediatric Ophthalmology and Strabismus 2013 guidelines. Considering cycloplegic retinoscopy as the gold standard, accuracy parameters of noncycloplegic photorefraction were calculated for detection of RARFs. Results: RARFs were found in 148 (36.8%) and 151 (37.6%) cases by cycloplegic retinoscopy and photorefraction, respectively. Plusoptix showed an overall 85.1% sensitivity for 90% specificity, 83.4% positive predictive value and 91.2% negative predictive value for detection of RARFs. Plusoptix had good specificity for detection of all specific types of RARFs (between 93.0 and 98.1%), and good sensitivity for detection of myopia (96.6%) and astigmatism (91.0%), however its sensitivity for detecting hyperopia RARFs was only 48.9%. Using a cutoff point of +1,5D for hyperopia instead of +3.5D (in children > 48 months), sensitivity can be improved to 88.6% in this group. Conclusions: The Plusoptix A09 is a useful, portable and accurate tool for the detection of RARFs in pediatric populations. However, in hyperopic RARFs an alternative cutoff value should be used.
id RCAP_a2b119ad319f90005f475bdc6308aa35
oai_identifier_str oai:ojs.revistas.rcaap.pt:article/7537
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling The performance of Plusoptix A09 in detection of Refractive Amblyopia Risk FactorsArtigos OriginaisPurpose: To assess the accuracy of the Plusoptix A09 noncycloplegic photorefraction for detection of refractive amblyopia risk factors (RARFs) in children and determine cutoff points. Methods: This study included 402 children observed in Pediatric Ophthalmology Clinic between June and December 2014. All children underwent initially photorefraction using Plusoptix A09 followed by cycloplegic retinoscopy (obtained during a complete ophthalmologic examination). Patients were considered to have RARFs based on American Association for Pediatric Ophthalmology and Strabismus 2013 guidelines. Considering cycloplegic retinoscopy as the gold standard, accuracy parameters of noncycloplegic photorefraction were calculated for detection of RARFs. Results: RARFs were found in 148 (36.8%) and 151 (37.6%) cases by cycloplegic retinoscopy and photorefraction, respectively. Plusoptix showed an overall 85.1% sensitivity for 90% specificity, 83.4% positive predictive value and 91.2% negative predictive value for detection of RARFs. Plusoptix had good specificity for detection of all specific types of RARFs (between 93.0 and 98.1%), and good sensitivity for detection of myopia (96.6%) and astigmatism (91.0%), however its sensitivity for detecting hyperopia RARFs was only 48.9%. Using a cutoff point of +1,5D for hyperopia instead of +3.5D (in children > 48 months), sensitivity can be improved to 88.6% in this group. Conclusions: The Plusoptix A09 is a useful, portable and accurate tool for the detection of RARFs in pediatric populations. However, in hyperopic RARFs an alternative cutoff value should be used.Ajnet2016-09-05T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://doi.org/10.48560/rspo.7537eng1646-69501646-6950Lemos, José AlbertoGonçalves, RitaRibeiro, IsabelMota, ÁgataMateus, CatarinaVieira, BrunaTenedório, Paulainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-22T17:05:56Zoai:ojs.revistas.rcaap.pt:article/7537Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:01:35.796104Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv The performance of Plusoptix A09 in detection of Refractive Amblyopia Risk Factors
title The performance of Plusoptix A09 in detection of Refractive Amblyopia Risk Factors
spellingShingle The performance of Plusoptix A09 in detection of Refractive Amblyopia Risk Factors
Lemos, José Alberto
Artigos Originais
title_short The performance of Plusoptix A09 in detection of Refractive Amblyopia Risk Factors
title_full The performance of Plusoptix A09 in detection of Refractive Amblyopia Risk Factors
title_fullStr The performance of Plusoptix A09 in detection of Refractive Amblyopia Risk Factors
title_full_unstemmed The performance of Plusoptix A09 in detection of Refractive Amblyopia Risk Factors
title_sort The performance of Plusoptix A09 in detection of Refractive Amblyopia Risk Factors
author Lemos, José Alberto
author_facet Lemos, José Alberto
Gonçalves, Rita
Ribeiro, Isabel
Mota, Ágata
Mateus, Catarina
Vieira, Bruna
Tenedório, Paula
author_role author
author2 Gonçalves, Rita
Ribeiro, Isabel
Mota, Ágata
Mateus, Catarina
Vieira, Bruna
Tenedório, Paula
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Lemos, José Alberto
Gonçalves, Rita
Ribeiro, Isabel
Mota, Ágata
Mateus, Catarina
Vieira, Bruna
Tenedório, Paula
dc.subject.por.fl_str_mv Artigos Originais
topic Artigos Originais
description Purpose: To assess the accuracy of the Plusoptix A09 noncycloplegic photorefraction for detection of refractive amblyopia risk factors (RARFs) in children and determine cutoff points. Methods: This study included 402 children observed in Pediatric Ophthalmology Clinic between June and December 2014. All children underwent initially photorefraction using Plusoptix A09 followed by cycloplegic retinoscopy (obtained during a complete ophthalmologic examination). Patients were considered to have RARFs based on American Association for Pediatric Ophthalmology and Strabismus 2013 guidelines. Considering cycloplegic retinoscopy as the gold standard, accuracy parameters of noncycloplegic photorefraction were calculated for detection of RARFs. Results: RARFs were found in 148 (36.8%) and 151 (37.6%) cases by cycloplegic retinoscopy and photorefraction, respectively. Plusoptix showed an overall 85.1% sensitivity for 90% specificity, 83.4% positive predictive value and 91.2% negative predictive value for detection of RARFs. Plusoptix had good specificity for detection of all specific types of RARFs (between 93.0 and 98.1%), and good sensitivity for detection of myopia (96.6%) and astigmatism (91.0%), however its sensitivity for detecting hyperopia RARFs was only 48.9%. Using a cutoff point of +1,5D for hyperopia instead of +3.5D (in children > 48 months), sensitivity can be improved to 88.6% in this group. Conclusions: The Plusoptix A09 is a useful, portable and accurate tool for the detection of RARFs in pediatric populations. However, in hyperopic RARFs an alternative cutoff value should be used.
publishDate 2016
dc.date.none.fl_str_mv 2016-09-05T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.48560/rspo.7537
url https://doi.org/10.48560/rspo.7537
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1646-6950
1646-6950
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Ajnet
publisher.none.fl_str_mv Ajnet
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130481160093696