Electroanalysis of Pharmaceuticals on Boron‐Doped Diamond Electrodes: A Review
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.22/14702 |
Resumo: | Boron‐doped diamond (BDD) electrodes possess outstanding physical, chemical, and electronic properties and have been successfully, yet in a limited way, explored in the electroanalysis of substances with therapeutic action (analgesics, antipyretics, antibiotics, anti‐inflammatories, antihypertensives, antidepressants, vitamins, and others) in diverse milieus (pharmaceutical formulations, urine, serum, whole blood, surface waters, seawaters, groundwater, wastewaters, etc.). Therefore, in this Review, a broad overview of the available scientific information on recent progress and achievements of the application of bare or modified BDD electrodes to the bioanalytical and environmental detection of pharmaceutical compounds is presented. The main parameters, for example boron concentration, applied operational conditions during pretreatment, chemical and physical structure, and other influential factors on the electroanalytical BDD electrodes performance, are discussed. |
id |
RCAP_a8826c8822e0b00316a8b0ab171d3a47 |
---|---|
oai_identifier_str |
oai:recipp.ipp.pt:10400.22/14702 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Electroanalysis of Pharmaceuticals on Boron‐Doped Diamond Electrodes: A ReviewBoron-doped diamondElectrodesElectroanalysisElectrochemical sensorPharmaceuticalsBoron‐doped diamond (BDD) electrodes possess outstanding physical, chemical, and electronic properties and have been successfully, yet in a limited way, explored in the electroanalysis of substances with therapeutic action (analgesics, antipyretics, antibiotics, anti‐inflammatories, antihypertensives, antidepressants, vitamins, and others) in diverse milieus (pharmaceutical formulations, urine, serum, whole blood, surface waters, seawaters, groundwater, wastewaters, etc.). Therefore, in this Review, a broad overview of the available scientific information on recent progress and achievements of the application of bare or modified BDD electrodes to the bioanalytical and environmental detection of pharmaceutical compounds is presented. The main parameters, for example boron concentration, applied operational conditions during pretreatment, chemical and physical structure, and other influential factors on the electroanalytical BDD electrodes performance, are discussed.John Wiley and SonsRepositório Científico do Instituto Politécnico do PortoSousa, Camila P.Ribeiro, Francisco W. P.Oliveira, Thiago M. B. F.Salazar‐Banda, Giancarlo R.Lima‐Neto, Pedro de Morais, SimoneCorreia, Adriana N.2019-05-022119-01-01T00:00:00Z2019-05-02T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/14702eng10.1002/celc.201801742metadata only accessinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-13T12:58:22Zoai:recipp.ipp.pt:10400.22/14702Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:34:31.549646Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Electroanalysis of Pharmaceuticals on Boron‐Doped Diamond Electrodes: A Review |
title |
Electroanalysis of Pharmaceuticals on Boron‐Doped Diamond Electrodes: A Review |
spellingShingle |
Electroanalysis of Pharmaceuticals on Boron‐Doped Diamond Electrodes: A Review Sousa, Camila P. Boron-doped diamond Electrodes Electroanalysis Electrochemical sensor Pharmaceuticals |
title_short |
Electroanalysis of Pharmaceuticals on Boron‐Doped Diamond Electrodes: A Review |
title_full |
Electroanalysis of Pharmaceuticals on Boron‐Doped Diamond Electrodes: A Review |
title_fullStr |
Electroanalysis of Pharmaceuticals on Boron‐Doped Diamond Electrodes: A Review |
title_full_unstemmed |
Electroanalysis of Pharmaceuticals on Boron‐Doped Diamond Electrodes: A Review |
title_sort |
Electroanalysis of Pharmaceuticals on Boron‐Doped Diamond Electrodes: A Review |
author |
Sousa, Camila P. |
author_facet |
Sousa, Camila P. Ribeiro, Francisco W. P. Oliveira, Thiago M. B. F. Salazar‐Banda, Giancarlo R. Lima‐Neto, Pedro de Morais, Simone Correia, Adriana N. |
author_role |
author |
author2 |
Ribeiro, Francisco W. P. Oliveira, Thiago M. B. F. Salazar‐Banda, Giancarlo R. Lima‐Neto, Pedro de Morais, Simone Correia, Adriana N. |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Repositório Científico do Instituto Politécnico do Porto |
dc.contributor.author.fl_str_mv |
Sousa, Camila P. Ribeiro, Francisco W. P. Oliveira, Thiago M. B. F. Salazar‐Banda, Giancarlo R. Lima‐Neto, Pedro de Morais, Simone Correia, Adriana N. |
dc.subject.por.fl_str_mv |
Boron-doped diamond Electrodes Electroanalysis Electrochemical sensor Pharmaceuticals |
topic |
Boron-doped diamond Electrodes Electroanalysis Electrochemical sensor Pharmaceuticals |
description |
Boron‐doped diamond (BDD) electrodes possess outstanding physical, chemical, and electronic properties and have been successfully, yet in a limited way, explored in the electroanalysis of substances with therapeutic action (analgesics, antipyretics, antibiotics, anti‐inflammatories, antihypertensives, antidepressants, vitamins, and others) in diverse milieus (pharmaceutical formulations, urine, serum, whole blood, surface waters, seawaters, groundwater, wastewaters, etc.). Therefore, in this Review, a broad overview of the available scientific information on recent progress and achievements of the application of bare or modified BDD electrodes to the bioanalytical and environmental detection of pharmaceutical compounds is presented. The main parameters, for example boron concentration, applied operational conditions during pretreatment, chemical and physical structure, and other influential factors on the electroanalytical BDD electrodes performance, are discussed. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-05-02 2019-05-02T00:00:00Z 2119-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.22/14702 |
url |
http://hdl.handle.net/10400.22/14702 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1002/celc.201801742 |
dc.rights.driver.fl_str_mv |
metadata only access info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
metadata only access |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
John Wiley and Sons |
publisher.none.fl_str_mv |
John Wiley and Sons |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1817552115679100928 |