Ionic permeability of soft contact lenses

Detalhes bibliográficos
Autor(a) principal: Silva, Ana Rita Ferreira da
Data de Publicação: 2013
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/28070
Resumo: Dissertação de mestrado em Optometria Avançada
id RCAP_a9f732e57c64550eae474405ae292eb8
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/28070
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Ionic permeability of soft contact lensesPermeabilidade iónica das lentes de contacto molesDifusãoHidrogelPermeabilidade iónicaSilicone hidrogelDiffusionHydrogelIonic permeabilitySilicone hydrogel617.7681.735Dissertação de mestrado em Optometria AvançadaA permeabilidade iónica das lentes de contacto ao sal é considerada pelos fabricantes um parâmetro de controlo de qualidade do material. Este parâmetro diz respeito à capacidade dos iões de Na + Cl- passarem através da matriz da lente de contacto e, acredita-se que o movimento da lente de contacto sobre a superfície ocular seja afetado quando este assume valores inferiores a 2-4 × 10 -7. Contudo existe pouca informação bibliográfica disponível referente a este assunto. Recorrendo à técnica de Ionoflux, em que a lente estudada é colocada entre dois compartimentos contendo água ultrapura e solução de 1M de NaCl, medimos a permeabilidade iónica de uma lente de hidrogel convencional e de três de silicone hidrogel. A razão pelo qual estas lentes foram escolhidas deve-se ao facto de terem diferentes conteúdos em água e desenho similar quando são do mesmo fabricante. Foram avaliadas as seguintes condições experimentais: permeabilidade iónica das lentes de contacto a iões Na+ Cl- com agitação na câmara dadora, sem agitação na câmara dadora depois de estas terem sido previamente banhadas numa solução NaCl 1M ou em água ultra pura. Foi também avaliado qual o efeito da potência das lentes (-1.00,-1.50 e -4.75) e o efeito de 1 mês de uso no valor da permeabilidade iónica das lentes Comfilcon A. Este trabalho permitiu constatar que existem diferenças na ordem de menos de 5% entre as condições experimentais com e sem agitação. Também se verificaram diferenças significantes no valor da permeabilidade iónica obtida quando as lentes foram previamente banhadas em água pura e em solução de 1M de NaCl. Resultados inovadores foram obtidos quando foi avaliado o efeito de uso durante um mês no valor de permeabilidade iónica: diminuição de cerca de 25 a 38% da permeabilidade iónica. Entre as lentes de -1.00 e -4.75 verificou-se um incremento de cerca de 26% na permeabilidade iónica.The ionic permeability of contact lenses salt, is regarded by manufacturers as a quality control parameter of the material. This parameter refers to the ability of the Na + Cl ions have to pass through the matrix of the contact lens and it is believed that the movement of the contact lens over the ocular surface is affected when this assumes values lower than 2.4 × 10 -7. However, there is little biographical information available concerning this subject. Using the Ionoflux Technique, wherein the lens studied was placed between two compartments, containing ultrapure water and 1M NaCl solution, we measure the ion permeability of a lens of conventional hydrogel and three silicon hydrogel. The reason that these lenses were chosen due to the fact that they have different water contents and similar design when they are of the same manufacturer. We evaluated the following experimental conditions: ionic permeability of contact lenses to Na+ and Cl- ions with stirring in the donor chamber, without stirring in the donor chamber, after they have previously been soaked in 1M NaCl solution or ultrapure water. It was also evaluated the effect of power lens (-1.00, -1.50 and -4.75) and the effect of 1 month using in the value of the ion permeability of lenses Comfilcon A. With this work it was established that there are differences in the order of less than 5% between the experimental conditions with and without stirring. Also no significant differences were found in the ionic permeability value obtained when lenses were first soaked in pure water and in a 1M NaCl solution. Completely innovative results were obtained when we evaluated the effect of using for a month in the ionic permeability value. With use there was a decrease of about 25 to 38% of the ionic permeability. Between -1.00 and -4.75 D lenses there was an increase of about 26% in ionic permeability.González-Méijome, José ManuelCompañ-Moreno, V.Universidade do MinhoSilva, Ana Rita Ferreira da20132013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/1822/28070eng201346923info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:27:21Zoai:repositorium.sdum.uminho.pt:1822/28070Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:21:54.786535Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Ionic permeability of soft contact lenses
Permeabilidade iónica das lentes de contacto moles
title Ionic permeability of soft contact lenses
spellingShingle Ionic permeability of soft contact lenses
Silva, Ana Rita Ferreira da
Difusão
Hidrogel
Permeabilidade iónica
Silicone hidrogel
Diffusion
Hydrogel
Ionic permeability
Silicone hydrogel
617.7
681.735
title_short Ionic permeability of soft contact lenses
title_full Ionic permeability of soft contact lenses
title_fullStr Ionic permeability of soft contact lenses
title_full_unstemmed Ionic permeability of soft contact lenses
title_sort Ionic permeability of soft contact lenses
author Silva, Ana Rita Ferreira da
author_facet Silva, Ana Rita Ferreira da
author_role author
dc.contributor.none.fl_str_mv González-Méijome, José Manuel
Compañ-Moreno, V.
Universidade do Minho
dc.contributor.author.fl_str_mv Silva, Ana Rita Ferreira da
dc.subject.por.fl_str_mv Difusão
Hidrogel
Permeabilidade iónica
Silicone hidrogel
Diffusion
Hydrogel
Ionic permeability
Silicone hydrogel
617.7
681.735
topic Difusão
Hidrogel
Permeabilidade iónica
Silicone hidrogel
Diffusion
Hydrogel
Ionic permeability
Silicone hydrogel
617.7
681.735
description Dissertação de mestrado em Optometria Avançada
publishDate 2013
dc.date.none.fl_str_mv 2013
2013-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/28070
url http://hdl.handle.net/1822/28070
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 201346923
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132687755116544