Third-degree Atrioventricular Block and Asystole Induced by Double-Lumen Tube Intubation
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://doi.org/10.25751/rspa.18094 |
Resumo: | Single-lung ventilation with a double lumen tube remains essential in thoracic surgery. Though these tubes insertion can be associated with multiple complications, from airway trauma or pulmonary shunt, potentially lethal complications can also occur, as we describe in the following case report. The authors believe the double lumen tube insertion in this case report induced a third-degree atrioventricular block and underline the lack of case reports and literature evidence regarding this potential complication. To our knowledge, no studies to date have reported third-degree A-V block occurring with double lumen tube insertion. |
id |
RCAP_ac04be18491f2b343e9356d2b4aaace9 |
---|---|
oai_identifier_str |
oai:ojs.revistas.rcaap.pt:article/18094 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Third-degree Atrioventricular Block and Asystole Induced by Double-Lumen Tube IntubationBloqueio Auriculoventricular de Terceiro Grau e Assistolia Induzidos por Intubação com Tubo de Duplo LúmenCaso ClínicoSingle-lung ventilation with a double lumen tube remains essential in thoracic surgery. Though these tubes insertion can be associated with multiple complications, from airway trauma or pulmonary shunt, potentially lethal complications can also occur, as we describe in the following case report. The authors believe the double lumen tube insertion in this case report induced a third-degree atrioventricular block and underline the lack of case reports and literature evidence regarding this potential complication. To our knowledge, no studies to date have reported third-degree A-V block occurring with double lumen tube insertion.A ventilação de pulmão único com recurso a tubo de duplo lúmen ocupa um papel primordial na cirurgia torácica. Embora a inserção destes tubos possa estar associada a complicações variadas, desde trauma da via aérea ou shunt pulmonar, podem também ocorrer complicações potencialmente fatais, como descrevemos neste caso. Os autores consideram que a inserção do tubo de duplo lúmen no caso descrito induziu um bloqueio auriculoventricular de 3º grau e alertam para a escassez de casos clínicos descritos na literatura acerca desta complicação. Os autores desconhecem a existência de casos clínicos prévios a descrever bloqueio auriculoventricular de 3º grau com inserção de tubos de duplo lúmen.Sociedade Portuguesa de Anestesiologia2019-09-16T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://doi.org/10.25751/rspa.18094eng0871-6099Cunha, Ana SofiaGalveias, InêsFreitas, AnaCondec, Patríciainfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-23T15:34:48Zoai:ojs.revistas.rcaap.pt:article/18094Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:04:16.131142Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Third-degree Atrioventricular Block and Asystole Induced by Double-Lumen Tube Intubation Bloqueio Auriculoventricular de Terceiro Grau e Assistolia Induzidos por Intubação com Tubo de Duplo Lúmen |
title |
Third-degree Atrioventricular Block and Asystole Induced by Double-Lumen Tube Intubation |
spellingShingle |
Third-degree Atrioventricular Block and Asystole Induced by Double-Lumen Tube Intubation Cunha, Ana Sofia Caso Clínico |
title_short |
Third-degree Atrioventricular Block and Asystole Induced by Double-Lumen Tube Intubation |
title_full |
Third-degree Atrioventricular Block and Asystole Induced by Double-Lumen Tube Intubation |
title_fullStr |
Third-degree Atrioventricular Block and Asystole Induced by Double-Lumen Tube Intubation |
title_full_unstemmed |
Third-degree Atrioventricular Block and Asystole Induced by Double-Lumen Tube Intubation |
title_sort |
Third-degree Atrioventricular Block and Asystole Induced by Double-Lumen Tube Intubation |
author |
Cunha, Ana Sofia |
author_facet |
Cunha, Ana Sofia Galveias, Inês Freitas, Ana Condec, Patrícia |
author_role |
author |
author2 |
Galveias, Inês Freitas, Ana Condec, Patrícia |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Cunha, Ana Sofia Galveias, Inês Freitas, Ana Condec, Patrícia |
dc.subject.por.fl_str_mv |
Caso Clínico |
topic |
Caso Clínico |
description |
Single-lung ventilation with a double lumen tube remains essential in thoracic surgery. Though these tubes insertion can be associated with multiple complications, from airway trauma or pulmonary shunt, potentially lethal complications can also occur, as we describe in the following case report. The authors believe the double lumen tube insertion in this case report induced a third-degree atrioventricular block and underline the lack of case reports and literature evidence regarding this potential complication. To our knowledge, no studies to date have reported third-degree A-V block occurring with double lumen tube insertion. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-09-16T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://doi.org/10.25751/rspa.18094 |
url |
https://doi.org/10.25751/rspa.18094 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
0871-6099 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Anestesiologia |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Anestesiologia |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799130505941090304 |