Smartphone and computer cephalometric analysis: A trueness and precision study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-28902022000400204 |
Resumo: | Abstract Objectives: Performing digital cephalometric analysis on apps is a convenient feature of handheld devices. The objective of this study was to assess the accuracy of the OneCeph cephalometric tracing app on a smartphone and computer. Methods: 34 lateral cephalograms were traced in two sessions using three methods: OneCeph on a smartphone, OneCeph on a computer, and NemoCeph on a computer as the reference. For trueness analysis, the measurements were compared between each test method and the reference. For precision analysis, the measurements were compared between sessions. Results: Regarding trueness analysis, significant differences were found between OneCeph and NemoCeph for ANB (smartphone, -0.3±0.68; computer, -0.3±0.52), OL/SN (smartphone, -1.1±2.68; computer -2.0±2.98), and GoGn/SN (smartphone, -0.5±1.27; computer, -0.8±1.56). OneCeph reproducibility was high for all cephalometric variables except OL/SN, both on the smartphone and the computer (ICC [95%CI]: 0.888 [0.773-0.944] and 0.842 [0.583-0.931], respectively). Repeatability was high for all cephalometric variables except OL/SN and UINA on the smartphone (ICC [95%CI]: 0.889 [0.730-0.950] and 0.831 [0.687-0.912], respectively). Tracing time was significantly higher for both OneCeph methods. Conclusions: OneCeph demonstrated adequate accuracy and efficiency on both interfaces. Clinical judgment is advised when interpreting the measurement output of handheld devices, which may provide a higher frequency of gross landmark identification errors. |
id |
RCAP_ad4c08e63d74346df0306a8303cce686 |
---|---|
oai_identifier_str |
oai:scielo:S1646-28902022000400204 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Smartphone and computer cephalometric analysis: A trueness and precision studyAccuracyAppsCephalometrySmartphoneAbstract Objectives: Performing digital cephalometric analysis on apps is a convenient feature of handheld devices. The objective of this study was to assess the accuracy of the OneCeph cephalometric tracing app on a smartphone and computer. Methods: 34 lateral cephalograms were traced in two sessions using three methods: OneCeph on a smartphone, OneCeph on a computer, and NemoCeph on a computer as the reference. For trueness analysis, the measurements were compared between each test method and the reference. For precision analysis, the measurements were compared between sessions. Results: Regarding trueness analysis, significant differences were found between OneCeph and NemoCeph for ANB (smartphone, -0.3±0.68; computer, -0.3±0.52), OL/SN (smartphone, -1.1±2.68; computer -2.0±2.98), and GoGn/SN (smartphone, -0.5±1.27; computer, -0.8±1.56). OneCeph reproducibility was high for all cephalometric variables except OL/SN, both on the smartphone and the computer (ICC [95%CI]: 0.888 [0.773-0.944] and 0.842 [0.583-0.931], respectively). Repeatability was high for all cephalometric variables except OL/SN and UINA on the smartphone (ICC [95%CI]: 0.889 [0.730-0.950] and 0.831 [0.687-0.912], respectively). Tracing time was significantly higher for both OneCeph methods. Conclusions: OneCeph demonstrated adequate accuracy and efficiency on both interfaces. Clinical judgment is advised when interpreting the measurement output of handheld devices, which may provide a higher frequency of gross landmark identification errors.Sociedade Portuguesa de Estomatologia e Medicina Dentária2022-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-28902022000400204Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial v.63 n.4 2022reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-28902022000400204Amorim,MónicaDiamantino,FernandaPereira,RuiJardim,Luísinfo:eu-repo/semantics/openAccess2024-02-06T17:21:12Zoai:scielo:S1646-28902022000400204Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:28:18.838447Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Smartphone and computer cephalometric analysis: A trueness and precision study |
title |
Smartphone and computer cephalometric analysis: A trueness and precision study |
spellingShingle |
Smartphone and computer cephalometric analysis: A trueness and precision study Amorim,Mónica Accuracy Apps Cephalometry Smartphone |
title_short |
Smartphone and computer cephalometric analysis: A trueness and precision study |
title_full |
Smartphone and computer cephalometric analysis: A trueness and precision study |
title_fullStr |
Smartphone and computer cephalometric analysis: A trueness and precision study |
title_full_unstemmed |
Smartphone and computer cephalometric analysis: A trueness and precision study |
title_sort |
Smartphone and computer cephalometric analysis: A trueness and precision study |
author |
Amorim,Mónica |
author_facet |
Amorim,Mónica Diamantino,Fernanda Pereira,Rui Jardim,Luís |
author_role |
author |
author2 |
Diamantino,Fernanda Pereira,Rui Jardim,Luís |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Amorim,Mónica Diamantino,Fernanda Pereira,Rui Jardim,Luís |
dc.subject.por.fl_str_mv |
Accuracy Apps Cephalometry Smartphone |
topic |
Accuracy Apps Cephalometry Smartphone |
description |
Abstract Objectives: Performing digital cephalometric analysis on apps is a convenient feature of handheld devices. The objective of this study was to assess the accuracy of the OneCeph cephalometric tracing app on a smartphone and computer. Methods: 34 lateral cephalograms were traced in two sessions using three methods: OneCeph on a smartphone, OneCeph on a computer, and NemoCeph on a computer as the reference. For trueness analysis, the measurements were compared between each test method and the reference. For precision analysis, the measurements were compared between sessions. Results: Regarding trueness analysis, significant differences were found between OneCeph and NemoCeph for ANB (smartphone, -0.3±0.68; computer, -0.3±0.52), OL/SN (smartphone, -1.1±2.68; computer -2.0±2.98), and GoGn/SN (smartphone, -0.5±1.27; computer, -0.8±1.56). OneCeph reproducibility was high for all cephalometric variables except OL/SN, both on the smartphone and the computer (ICC [95%CI]: 0.888 [0.773-0.944] and 0.842 [0.583-0.931], respectively). Repeatability was high for all cephalometric variables except OL/SN and UINA on the smartphone (ICC [95%CI]: 0.889 [0.730-0.950] and 0.831 [0.687-0.912], respectively). Tracing time was significantly higher for both OneCeph methods. Conclusions: OneCeph demonstrated adequate accuracy and efficiency on both interfaces. Clinical judgment is advised when interpreting the measurement output of handheld devices, which may provide a higher frequency of gross landmark identification errors. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-12-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-28902022000400204 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-28902022000400204 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S1646-28902022000400204 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Estomatologia e Medicina Dentária |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Estomatologia e Medicina Dentária |
dc.source.none.fl_str_mv |
Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial v.63 n.4 2022 reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799137353070018560 |