Development of a manometric monitoring method for early detection of air microbiological contamination in the bloodstream

Detalhes bibliográficos
Autor(a) principal: dos Santos-Neto, Agenor G.
Data de Publicação: 2021
Outros Autores: Pinheiro, Malone S., dos Santos, Monica C., Alves, Lumar L., Poderoso, Renata R. S., Cardoso, Juliana C., Severino, Patricia, Souto, Eliana B., de Albuquerque-Junior, Ricardo L. C.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/73477
Resumo: Atmospheric air is a microbial habitat of pathogenic bioaerosols that may pose serious risks to humans. A commonly laboratory-based approach for the diagnosis of such infections in the bloodstream is the blood culture analysis. Its clinical relevance is attributed to the fact that these infections are characterized by high rates of morbidity and mortality, requiring the need for efficient methods for rapid diagnosis. For this reason, our study aimed to develop a method of manometric monitoring for the rapid detection of viable microorganisms in blood culture vials. A methodology was developed to detect pressure variation in intra-vials through a manometric instrument that was coupled to vials of blood culture containing culture broth that allowed microbial growth. This device allowed the early detection of microbial activity based on the production or use of intra-flask gases as a result of microbial metabolic activity. The analyzed variables were the pressure as a function of time, microbial species, and culture medium. The highest pressure found in the flasks without microorganisms was 40 mmHg between 2 and 6 h, and the lowest pressure was 42 mmHg between 21 and 24 h. The variation of the internal pressure in blood culture flasks according to different groups of microorganisms as a function of time demonstrated that the fermentative gram-negative bacilli and gram-positive cocci exhibited a significant increase in relation to their respective control groups (p < 0.001). The non-fermenting gram-negative bacilli showed expected results in relation to the pressure variation in which the production of negative pressures was noticed during the period of analysis, with a significant difference with respect to their control groups (p < 0.001). The developed methodology for the early detection of microorganisms responsible for bloodstream infection was demonstrated to be effective.
id RCAP_ae6ae6de0baa72e5b273d773301a72e7
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/73477
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Development of a manometric monitoring method for early detection of air microbiological contamination in the bloodstreamAtmospheric pathogens diagnosisBloodstream infectionsMicroorganismsGramnegative bacteriaManometric methodCiências Médicas::Biotecnologia MédicaScience & TechnologyAtmospheric air is a microbial habitat of pathogenic bioaerosols that may pose serious risks to humans. A commonly laboratory-based approach for the diagnosis of such infections in the bloodstream is the blood culture analysis. Its clinical relevance is attributed to the fact that these infections are characterized by high rates of morbidity and mortality, requiring the need for efficient methods for rapid diagnosis. For this reason, our study aimed to develop a method of manometric monitoring for the rapid detection of viable microorganisms in blood culture vials. A methodology was developed to detect pressure variation in intra-vials through a manometric instrument that was coupled to vials of blood culture containing culture broth that allowed microbial growth. This device allowed the early detection of microbial activity based on the production or use of intra-flask gases as a result of microbial metabolic activity. The analyzed variables were the pressure as a function of time, microbial species, and culture medium. The highest pressure found in the flasks without microorganisms was 40 mmHg between 2 and 6 h, and the lowest pressure was 42 mmHg between 21 and 24 h. The variation of the internal pressure in blood culture flasks according to different groups of microorganisms as a function of time demonstrated that the fermentative gram-negative bacilli and gram-positive cocci exhibited a significant increase in relation to their respective control groups (p < 0.001). The non-fermenting gram-negative bacilli showed expected results in relation to the pressure variation in which the production of negative pressures was noticed during the period of analysis, with a significant difference with respect to their control groups (p < 0.001). The developed methodology for the early detection of microorganisms responsible for bloodstream infection was demonstrated to be effective.e Fundação de Apoio à Pesquisa e à Inovação Tecnológica do Estado de Sergipe-Program Centelha (FAPITEC/SE) and by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES), and Portuguese Science and Technology Foundation (FCT) through the project UIDB/04469/2020 (strategic fund) funded by national funds, and co-financed Education (FCT/MEC) from national funds and FEDER, under the Partnership Agreement PT2020info:eu-repo/semantics/publishedVersionMDPIUniversidade do Minhodos Santos-Neto, Agenor G.Pinheiro, Malone S.dos Santos, Monica C.Alves, Lumar L.Poderoso, Renata R. S.Cardoso, Juliana C.Severino, PatriciaSouto, Eliana B.de Albuquerque-Junior, Ricardo L. C.2021-05-302021-05-30T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/73477engdos Santos-Neto, Agenor G.; Pinheiro, Malone S.; dos Santos, Monica C.; Alves, Lumar L.; Poderoso, Renata R. S.; Cardoso, Juliana C.; Severino, Patricia; Souto, Eliana; de Albuquerque-Junior, Ricardo L. C., Development of a manometric monitoring method for early detection of air microbiological contamination in the bloodstream. Atmosphere, 12(6), 702, 20212073-443310.3390/atmos12060702https://www.mdpi.com/2073-4433/12/6/702info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T11:55:47Zoai:repositorium.sdum.uminho.pt:1822/73477Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:45:20.492507Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Development of a manometric monitoring method for early detection of air microbiological contamination in the bloodstream
title Development of a manometric monitoring method for early detection of air microbiological contamination in the bloodstream
spellingShingle Development of a manometric monitoring method for early detection of air microbiological contamination in the bloodstream
dos Santos-Neto, Agenor G.
Atmospheric pathogens diagnosis
Bloodstream infections
Microorganisms
Gramnegative bacteria
Manometric method
Ciências Médicas::Biotecnologia Médica
Science & Technology
title_short Development of a manometric monitoring method for early detection of air microbiological contamination in the bloodstream
title_full Development of a manometric monitoring method for early detection of air microbiological contamination in the bloodstream
title_fullStr Development of a manometric monitoring method for early detection of air microbiological contamination in the bloodstream
title_full_unstemmed Development of a manometric monitoring method for early detection of air microbiological contamination in the bloodstream
title_sort Development of a manometric monitoring method for early detection of air microbiological contamination in the bloodstream
author dos Santos-Neto, Agenor G.
author_facet dos Santos-Neto, Agenor G.
Pinheiro, Malone S.
dos Santos, Monica C.
Alves, Lumar L.
Poderoso, Renata R. S.
Cardoso, Juliana C.
Severino, Patricia
Souto, Eliana B.
de Albuquerque-Junior, Ricardo L. C.
author_role author
author2 Pinheiro, Malone S.
dos Santos, Monica C.
Alves, Lumar L.
Poderoso, Renata R. S.
Cardoso, Juliana C.
Severino, Patricia
Souto, Eliana B.
de Albuquerque-Junior, Ricardo L. C.
author2_role author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv dos Santos-Neto, Agenor G.
Pinheiro, Malone S.
dos Santos, Monica C.
Alves, Lumar L.
Poderoso, Renata R. S.
Cardoso, Juliana C.
Severino, Patricia
Souto, Eliana B.
de Albuquerque-Junior, Ricardo L. C.
dc.subject.por.fl_str_mv Atmospheric pathogens diagnosis
Bloodstream infections
Microorganisms
Gramnegative bacteria
Manometric method
Ciências Médicas::Biotecnologia Médica
Science & Technology
topic Atmospheric pathogens diagnosis
Bloodstream infections
Microorganisms
Gramnegative bacteria
Manometric method
Ciências Médicas::Biotecnologia Médica
Science & Technology
description Atmospheric air is a microbial habitat of pathogenic bioaerosols that may pose serious risks to humans. A commonly laboratory-based approach for the diagnosis of such infections in the bloodstream is the blood culture analysis. Its clinical relevance is attributed to the fact that these infections are characterized by high rates of morbidity and mortality, requiring the need for efficient methods for rapid diagnosis. For this reason, our study aimed to develop a method of manometric monitoring for the rapid detection of viable microorganisms in blood culture vials. A methodology was developed to detect pressure variation in intra-vials through a manometric instrument that was coupled to vials of blood culture containing culture broth that allowed microbial growth. This device allowed the early detection of microbial activity based on the production or use of intra-flask gases as a result of microbial metabolic activity. The analyzed variables were the pressure as a function of time, microbial species, and culture medium. The highest pressure found in the flasks without microorganisms was 40 mmHg between 2 and 6 h, and the lowest pressure was 42 mmHg between 21 and 24 h. The variation of the internal pressure in blood culture flasks according to different groups of microorganisms as a function of time demonstrated that the fermentative gram-negative bacilli and gram-positive cocci exhibited a significant increase in relation to their respective control groups (p < 0.001). The non-fermenting gram-negative bacilli showed expected results in relation to the pressure variation in which the production of negative pressures was noticed during the period of analysis, with a significant difference with respect to their control groups (p < 0.001). The developed methodology for the early detection of microorganisms responsible for bloodstream infection was demonstrated to be effective.
publishDate 2021
dc.date.none.fl_str_mv 2021-05-30
2021-05-30T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/73477
url http://hdl.handle.net/1822/73477
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv dos Santos-Neto, Agenor G.; Pinheiro, Malone S.; dos Santos, Monica C.; Alves, Lumar L.; Poderoso, Renata R. S.; Cardoso, Juliana C.; Severino, Patricia; Souto, Eliana; de Albuquerque-Junior, Ricardo L. C., Development of a manometric monitoring method for early detection of air microbiological contamination in the bloodstream. Atmosphere, 12(6), 702, 2021
2073-4433
10.3390/atmos12060702
https://www.mdpi.com/2073-4433/12/6/702
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132205673349120