Novel biosensing device for point-of-care applications with plastic antibodies grown on Au-Screen Printed Electrodes

Detalhes bibliográficos
Autor(a) principal: Moreira, Felismina T. C.
Data de Publicação: 2013
Outros Autores: Dutra, Rosa A.F., Noronha, João P. C., Fernandes, João S., Sales, M. Goreti F.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.22/6731
Resumo: A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.
id RCAP_b2e4fe181fc032e1c9fca0ef82228a85
oai_identifier_str oai:recipp.ipp.pt:10400.22/6731
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Novel biosensing device for point-of-care applications with plastic antibodies grown on Au-Screen Printed ElectrodesSurface molecular imprintSelf-assembled monolayerScreen-printed electrodesCardiac biomarkerMyoglobinBiosensorA gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.ElsevierRepositório Científico do Instituto Politécnico do PortoMoreira, Felismina T. C.Dutra, Rosa A.F.Noronha, João P. C.Fernandes, João S.Sales, M. Goreti F.2015-10-16T14:24:46Z20132013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/6731eng10.1016/j.snb.2013.03.099info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-13T12:47:08Zoai:recipp.ipp.pt:10400.22/6731Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:27:17.439088Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Novel biosensing device for point-of-care applications with plastic antibodies grown on Au-Screen Printed Electrodes
title Novel biosensing device for point-of-care applications with plastic antibodies grown on Au-Screen Printed Electrodes
spellingShingle Novel biosensing device for point-of-care applications with plastic antibodies grown on Au-Screen Printed Electrodes
Moreira, Felismina T. C.
Surface molecular imprint
Self-assembled monolayer
Screen-printed electrodes
Cardiac biomarker
Myoglobin
Biosensor
title_short Novel biosensing device for point-of-care applications with plastic antibodies grown on Au-Screen Printed Electrodes
title_full Novel biosensing device for point-of-care applications with plastic antibodies grown on Au-Screen Printed Electrodes
title_fullStr Novel biosensing device for point-of-care applications with plastic antibodies grown on Au-Screen Printed Electrodes
title_full_unstemmed Novel biosensing device for point-of-care applications with plastic antibodies grown on Au-Screen Printed Electrodes
title_sort Novel biosensing device for point-of-care applications with plastic antibodies grown on Au-Screen Printed Electrodes
author Moreira, Felismina T. C.
author_facet Moreira, Felismina T. C.
Dutra, Rosa A.F.
Noronha, João P. C.
Fernandes, João S.
Sales, M. Goreti F.
author_role author
author2 Dutra, Rosa A.F.
Noronha, João P. C.
Fernandes, João S.
Sales, M. Goreti F.
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Politécnico do Porto
dc.contributor.author.fl_str_mv Moreira, Felismina T. C.
Dutra, Rosa A.F.
Noronha, João P. C.
Fernandes, João S.
Sales, M. Goreti F.
dc.subject.por.fl_str_mv Surface molecular imprint
Self-assembled monolayer
Screen-printed electrodes
Cardiac biomarker
Myoglobin
Biosensor
topic Surface molecular imprint
Self-assembled monolayer
Screen-printed electrodes
Cardiac biomarker
Myoglobin
Biosensor
description A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.
publishDate 2013
dc.date.none.fl_str_mv 2013
2013-01-01T00:00:00Z
2015-10-16T14:24:46Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.22/6731
url http://hdl.handle.net/10400.22/6731
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.snb.2013.03.099
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131368316207104