Resumo: This paper describes the use of a FIA system for the automatic determination of uric acid in urine, using a tubular amperometric detector. In this system, glassy carbon electrodes of tubular configuration were activated by successive cyclical scans from - 0.30 to 2.00 V versus Ag/AgCl reference electrode in 0.50 mol.L-1 sulphuric acid solution. Samples were diluted in supporting electrolyte before analysis and no other pre-treatment was employed. Such dilution enabled the matrix effects to be reduced and therefore improving the sensitivity provided by the activation step that allows the uric acid (UA) to be detected at lower concentration levels after dilution. Uric acid determination was performed in a single channel FIA manifold, which provided reproducibility of sample transport to the detector and enabled a sampling rate of 120 samples per hour to be achieved. The tubular configuration of the cell offered robustness to the system since it was rigidly fixed to the manifold, allowing the manifold to be generalised for routine analysis application. The results obtained with the FIA system for UA determination in urine were compared with those from the enzymatic method used in clinical analysis laboratories. No statistical difference between methods was found at the 95% confidence level. Relative deviations between both methods were within ± 4% and the proposed system showed good repeatability (about 3%, n = 10).
id RCAP_b306dad7da39bfdafcdb514fd4769878
oai_identifier_str oai:scielo:S0872-19042004000300006
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Automatic Determination of Uric Acid in Urine in a FIA System with a Tubular Amperometric Detectouric acidamperometric detectiontubular electrodesFIAThis paper describes the use of a FIA system for the automatic determination of uric acid in urine, using a tubular amperometric detector. In this system, glassy carbon electrodes of tubular configuration were activated by successive cyclical scans from - 0.30 to 2.00 V versus Ag/AgCl reference electrode in 0.50 mol.L-1 sulphuric acid solution. Samples were diluted in supporting electrolyte before analysis and no other pre-treatment was employed. Such dilution enabled the matrix effects to be reduced and therefore improving the sensitivity provided by the activation step that allows the uric acid (UA) to be detected at lower concentration levels after dilution. Uric acid determination was performed in a single channel FIA manifold, which provided reproducibility of sample transport to the detector and enabled a sampling rate of 120 samples per hour to be achieved. The tubular configuration of the cell offered robustness to the system since it was rigidly fixed to the manifold, allowing the manifold to be generalised for routine analysis application. The results obtained with the FIA system for UA determination in urine were compared with those from the enzymatic method used in clinical analysis laboratories. No statistical difference between methods was found at the 95% confidence level. Relative deviations between both methods were within ± 4% and the proposed system showed good repeatability (about 3%, n = 10).Sociedade Portuguesa de Electroquímica2004-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042004000300006Portugaliae Electrochimica Acta v.22 n.3 2004reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042004000300006Quinaz Garcia,M. BeatrizLima,José L.F.C.Silva,M. LuísaSousa,João P.info:eu-repo/semantics/openAccess2024-02-06T17:06:44Zoai:scielo:S0872-19042004000300006Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:19:57.761282Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Automatic Determination of Uric Acid in Urine in a FIA System with a Tubular Amperometric Detecto
title Automatic Determination of Uric Acid in Urine in a FIA System with a Tubular Amperometric Detecto
spellingShingle Automatic Determination of Uric Acid in Urine in a FIA System with a Tubular Amperometric Detecto
Quinaz Garcia,M. Beatriz
uric acid
amperometric detection
tubular electrodes
FIA
title_short Automatic Determination of Uric Acid in Urine in a FIA System with a Tubular Amperometric Detecto
title_full Automatic Determination of Uric Acid in Urine in a FIA System with a Tubular Amperometric Detecto
title_fullStr Automatic Determination of Uric Acid in Urine in a FIA System with a Tubular Amperometric Detecto
title_full_unstemmed Automatic Determination of Uric Acid in Urine in a FIA System with a Tubular Amperometric Detecto
title_sort Automatic Determination of Uric Acid in Urine in a FIA System with a Tubular Amperometric Detecto
author Quinaz Garcia,M. Beatriz
author_facet Quinaz Garcia,M. Beatriz
Lima,José L.F.C.
Silva,M. Luísa
Sousa,João P.
author_role author
author2 Lima,José L.F.C.
Silva,M. Luísa
Sousa,João P.
author2_role author
author
author
dc.contributor.author.fl_str_mv Quinaz Garcia,M. Beatriz
Lima,José L.F.C.
Silva,M. Luísa
Sousa,João P.
dc.subject.por.fl_str_mv uric acid
amperometric detection
tubular electrodes
FIA
topic uric acid
amperometric detection
tubular electrodes
FIA
description This paper describes the use of a FIA system for the automatic determination of uric acid in urine, using a tubular amperometric detector. In this system, glassy carbon electrodes of tubular configuration were activated by successive cyclical scans from - 0.30 to 2.00 V versus Ag/AgCl reference electrode in 0.50 mol.L-1 sulphuric acid solution. Samples were diluted in supporting electrolyte before analysis and no other pre-treatment was employed. Such dilution enabled the matrix effects to be reduced and therefore improving the sensitivity provided by the activation step that allows the uric acid (UA) to be detected at lower concentration levels after dilution. Uric acid determination was performed in a single channel FIA manifold, which provided reproducibility of sample transport to the detector and enabled a sampling rate of 120 samples per hour to be achieved. The tubular configuration of the cell offered robustness to the system since it was rigidly fixed to the manifold, allowing the manifold to be generalised for routine analysis application. The results obtained with the FIA system for UA determination in urine were compared with those from the enzymatic method used in clinical analysis laboratories. No statistical difference between methods was found at the 95% confidence level. Relative deviations between both methods were within ± 4% and the proposed system showed good repeatability (about 3%, n = 10).
publishDate 2004
dc.date.none.fl_str_mv 2004-01-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042004000300006
url http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042004000300006
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042004000300006
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Portuguesa de Electroquímica
publisher.none.fl_str_mv Sociedade Portuguesa de Electroquímica
dc.source.none.fl_str_mv Portugaliae Electrochimica Acta v.22 n.3 2004
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799137288944353280