Avaliação da eficácia e segurança do encerramento percutâneo de foramen ovale patente

Detalhes bibliográficos
Autor(a) principal: Azevedo, Patrícia Coelho de
Data de Publicação: 2019
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/89578
Resumo: Trabalho Final do Mestrado Integrado em Medicina apresentado à Faculdade de Medicina
id RCAP_b3bd40eef6f3531a6ef879e9965c4f79
oai_identifier_str oai:estudogeral.uc.pt:10316/89578
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Avaliação da eficácia e segurança do encerramento percutâneo de foramen ovale patenteEvaluation of the efficiency and safety of the percutaneous closure of the patent foramen ovaleacidente vascular cerebralforamen ovale patenteembolia paradoxalencerramento percutâneocriptogénicostrokepatent foramen ovaleparadoxical embolismpercutaneous closurecryptogenicTrabalho Final do Mestrado Integrado em Medicina apresentado à Faculdade de MedicinaIntrodução: A associação entre um evento cerebrovascular isquémico e a presença de foramen ovale patente (FOP) não é consensual. Esta investigação visa estudar doentes com evento cerebrovascular isquémico, de etiologia indeterminada (criptogénico), e avaliar a eficácia e segurança do encerramento percutâneo na prevenção de novo evento cerebrovascular.Métodos: Estudo observacional retrospetivo, que incluiu doentes com antecedentes de acidente isquémico transitório (AIT) ou acidente vascular cerebral (AVC), criptogénicos, submetidos a encerramento percutâneo de FOP para prevenção secundária de embolia paradoxal. O desfecho primário de eficácia foi definido como ocorrência de AVC/AIT ou embolismo periférico durante o seguimento. O desfecho primário de segurança foi definido como ocorrência de fibrilhação auricular de novo. Os desfechos secundários foram a ocorrência de morte, evento cardiovascular ou hemorragia major no seguimento clínico.Resultados: A amostra incluiu 113 casos de encerramento percutâneo de FOP com seguimento médio de 14.8±8.9 meses. Foram registadas as características anatómicas do FOP e as características clínicas de risco de recorrência isquémica. Os algoritmos de risco RoPE, AF-RoPE e CHA2DS2VASc foram obtidos para cada doente. Não se registaram complicações relacionadas com o procedimento. No seguimento, observaram-se 3 desfechos primários de eficácia na forma de AVC (2.8%), traduzindo uma redução de 59.4% no risco de recorrência de AVC/AIT comparativamente à terapêutica médica. Observaram-se 3 desfechos de fibrilhação auricular paroxística (2.8%) e uma tromboembolia pulmonar aguda (0.9%). Não se registou mortalidade. O AF-RoPE score foi significativo na discriminação de recorrência de AVC (р=0.035).Discussão: Os nossos resultados estão de acordo com os estudos que demonstram eficácia e segurança do encerramento do FOP na prevenção de eventos adversos cerebrovasculares, e vantagem da utilização do AF-RoPE score para a seleção dos doentes que beneficiam do encerramento.Conclusão: O encerramento percutâneo de FOP é um procedimento eficaz e seguro na prevenção de eventos adversos cerebrovasculares, particularmente em doentes com alto AF-RoPE score.Introduction: The association between an ischemic cerebrovascular event and the presence of patent foramen ovale (PFO) is not consensual. This research aims to study patients with cerebrovascular event of unknown etiology (cryptogenic) and to evaluate the efficiency and safety of the percutaneous closure in the prevention of new cerebrovascular event. Methods: Retrospective observational study, which included patients with a history of transient ischemic attack (TIA) or stroke, cryptogenic, undergoing percutaneous closure of FOP for secondary prevention of paradoxical embolism. The primary efficacy endpoint was defined as the occurrence of stroke/TIA or peripheral embolism during follow-up. The primary safety endpoint was defined as the occurrence of atrial fibrillation. Secondary outcomes were death, major cardiovascular events, or major bleeding at follow-up.Results: The sample included 113 cases of percutaneous closure of FOP with an average follow-up of 14.8 ± 8.9 months. The anatomical characteristics of PFO and the clinical characteristics of risk of ischemic recurrence were recorded. The risk algorithms RoPE, AF-RoPE and CHA2DS2VASc were obtained for each patient. In the follow-up, 3 primary efficacy endpoint (2.8%) were observed, reflecting a 59.4% reduction in the risk of recurrence of stroke/TIA compared to medical therapy. There were 3 cases of paroxysmal atrial fibrillation (2.8%) and one acute pulmonary thromboembolism (0.9%). There was no mortality. The AF-RoPE score was significant in discriminating recurrence of stroke (р = 0.035).Discussion: The results are in line with the studies which demonstrate the efficiency and safety of closure of PFO in the prevention of adverse cerebrovascular events, and an advantage in using the AF-RoPE score for the selection of patients who benefit from the closure.Conclusion: The percutaneous closure of PFO is an effective and safe procedure in the prevention of adverse cerebrovascular events, particularly in patients with high AF-RoPE score.2019-01-28info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/10316/89578http://hdl.handle.net/10316/89578TID:202479366porAzevedo, Patrícia Coelho deinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-05-25T01:45:42Zoai:estudogeral.uc.pt:10316/89578Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:09:51.121784Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Avaliação da eficácia e segurança do encerramento percutâneo de foramen ovale patente
Evaluation of the efficiency and safety of the percutaneous closure of the patent foramen ovale
title Avaliação da eficácia e segurança do encerramento percutâneo de foramen ovale patente
spellingShingle Avaliação da eficácia e segurança do encerramento percutâneo de foramen ovale patente
Azevedo, Patrícia Coelho de
acidente vascular cerebral
foramen ovale patente
embolia paradoxal
encerramento percutâneo
criptogénico
stroke
patent foramen ovale
paradoxical embolism
percutaneous closure
cryptogenic
title_short Avaliação da eficácia e segurança do encerramento percutâneo de foramen ovale patente
title_full Avaliação da eficácia e segurança do encerramento percutâneo de foramen ovale patente
title_fullStr Avaliação da eficácia e segurança do encerramento percutâneo de foramen ovale patente
title_full_unstemmed Avaliação da eficácia e segurança do encerramento percutâneo de foramen ovale patente
title_sort Avaliação da eficácia e segurança do encerramento percutâneo de foramen ovale patente
author Azevedo, Patrícia Coelho de
author_facet Azevedo, Patrícia Coelho de
author_role author
dc.contributor.author.fl_str_mv Azevedo, Patrícia Coelho de
dc.subject.por.fl_str_mv acidente vascular cerebral
foramen ovale patente
embolia paradoxal
encerramento percutâneo
criptogénico
stroke
patent foramen ovale
paradoxical embolism
percutaneous closure
cryptogenic
topic acidente vascular cerebral
foramen ovale patente
embolia paradoxal
encerramento percutâneo
criptogénico
stroke
patent foramen ovale
paradoxical embolism
percutaneous closure
cryptogenic
description Trabalho Final do Mestrado Integrado em Medicina apresentado à Faculdade de Medicina
publishDate 2019
dc.date.none.fl_str_mv 2019-01-28
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/89578
http://hdl.handle.net/10316/89578
TID:202479366
url http://hdl.handle.net/10316/89578
identifier_str_mv TID:202479366
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1817552178268602368