The influence of ventilation systems on domestic gas appliances: an experimental study

Detalhes bibliográficos
Autor(a) principal: Pinto, Manuel
Data de Publicação: 2013
Outros Autores: Viegas, João
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.19/2388
Resumo: Ventilation systems play an important role in the energy consumption of heating and cooling, defining hygrothermal conditions and air quality of dwellings. Among other functions, they are absolutely necessary to ensure oxygen levels needed for household combustion appliances. In Portugal in multifamily housing and with natural ventilation systems, installing a mechanical exhaust fan in every kitchen (decentralized ventilation) is common. In this paper, the impact of such a device is evaluated regarding the performance of a water heating appliance for heating the indoor environment or for domestic hot water (B-type gas appliance usually installed in the kitchen). The combination of natural or mechanical ventilation in the kitchen with the natural exhaust of the gas appliance’s combustion products were tested as well as the evaluation of critical conditions that lead to stopping the gas appliance safely or to reversing the combustion products in the respective exhaust duct. One of the main conclusions to be drawn is that in the case of mechanical exhaust in the kitchen simultaneously with the natural exhaust of the gas appliance’s combustion products, the kitchen’s exterior air inlet is a key device for ensuring proper exhaust of combustion products. In extreme situations, reduced air intake by other means or high extraction flows, they can prevent safely stopping the appliance or even reversing the flow of the combustion products. For this purpose, the maximum flow of mechanical exhaust should also be limited.
id RCAP_b73218c9c6526b8e442b15f1984c3374
oai_identifier_str oai:repositorio.ipv.pt:10400.19/2388
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling The influence of ventilation systems on domestic gas appliances: an experimental studyAir permeabilityGas appliancesDwellingsVentilation systemsReverse flowVentilation systems play an important role in the energy consumption of heating and cooling, defining hygrothermal conditions and air quality of dwellings. Among other functions, they are absolutely necessary to ensure oxygen levels needed for household combustion appliances. In Portugal in multifamily housing and with natural ventilation systems, installing a mechanical exhaust fan in every kitchen (decentralized ventilation) is common. In this paper, the impact of such a device is evaluated regarding the performance of a water heating appliance for heating the indoor environment or for domestic hot water (B-type gas appliance usually installed in the kitchen). The combination of natural or mechanical ventilation in the kitchen with the natural exhaust of the gas appliance’s combustion products were tested as well as the evaluation of critical conditions that lead to stopping the gas appliance safely or to reversing the combustion products in the respective exhaust duct. One of the main conclusions to be drawn is that in the case of mechanical exhaust in the kitchen simultaneously with the natural exhaust of the gas appliance’s combustion products, the kitchen’s exterior air inlet is a key device for ensuring proper exhaust of combustion products. In extreme situations, reduced air intake by other means or high extraction flows, they can prevent safely stopping the appliance or even reversing the flow of the combustion products. For this purpose, the maximum flow of mechanical exhaust should also be limited.Repositório Científico do Instituto Politécnico de ViseuPinto, ManuelViegas, João2015-01-02T01:30:08Z20132013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.19/2388eng10.1016/j.buildenv.2013.07.008info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-01-16T15:25:39Zoai:repositorio.ipv.pt:10400.19/2388Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:41:35.189329Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv The influence of ventilation systems on domestic gas appliances: an experimental study
title The influence of ventilation systems on domestic gas appliances: an experimental study
spellingShingle The influence of ventilation systems on domestic gas appliances: an experimental study
Pinto, Manuel
Air permeability
Gas appliances
Dwellings
Ventilation systems
Reverse flow
title_short The influence of ventilation systems on domestic gas appliances: an experimental study
title_full The influence of ventilation systems on domestic gas appliances: an experimental study
title_fullStr The influence of ventilation systems on domestic gas appliances: an experimental study
title_full_unstemmed The influence of ventilation systems on domestic gas appliances: an experimental study
title_sort The influence of ventilation systems on domestic gas appliances: an experimental study
author Pinto, Manuel
author_facet Pinto, Manuel
Viegas, João
author_role author
author2 Viegas, João
author2_role author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Politécnico de Viseu
dc.contributor.author.fl_str_mv Pinto, Manuel
Viegas, João
dc.subject.por.fl_str_mv Air permeability
Gas appliances
Dwellings
Ventilation systems
Reverse flow
topic Air permeability
Gas appliances
Dwellings
Ventilation systems
Reverse flow
description Ventilation systems play an important role in the energy consumption of heating and cooling, defining hygrothermal conditions and air quality of dwellings. Among other functions, they are absolutely necessary to ensure oxygen levels needed for household combustion appliances. In Portugal in multifamily housing and with natural ventilation systems, installing a mechanical exhaust fan in every kitchen (decentralized ventilation) is common. In this paper, the impact of such a device is evaluated regarding the performance of a water heating appliance for heating the indoor environment or for domestic hot water (B-type gas appliance usually installed in the kitchen). The combination of natural or mechanical ventilation in the kitchen with the natural exhaust of the gas appliance’s combustion products were tested as well as the evaluation of critical conditions that lead to stopping the gas appliance safely or to reversing the combustion products in the respective exhaust duct. One of the main conclusions to be drawn is that in the case of mechanical exhaust in the kitchen simultaneously with the natural exhaust of the gas appliance’s combustion products, the kitchen’s exterior air inlet is a key device for ensuring proper exhaust of combustion products. In extreme situations, reduced air intake by other means or high extraction flows, they can prevent safely stopping the appliance or even reversing the flow of the combustion products. For this purpose, the maximum flow of mechanical exhaust should also be limited.
publishDate 2013
dc.date.none.fl_str_mv 2013
2013-01-01T00:00:00Z
2015-01-02T01:30:08Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.19/2388
url http://hdl.handle.net/10400.19/2388
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.buildenv.2013.07.008
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130881719271424