Resumo: The combustion instability and ash agglomeration in a wood pellet boiler were investigated in this study. The tests were conducted using the Taguchi method of orthogonal array L<sub>27</sub>(13<sup>3</sup>). Several parameters are applied, including grate area (GA), primary to secondary air split ratio (SR), excess air (EA), and fuel power (P). Pine wood pellets were used, and the boiler’s nominal load was 20 kW. The results show that instability during combustion occurs since the fuel bed rises as the accumulation of the unburned wood pellets on the grate causes a slow combustion rate and pressure drop, which creates noise and disturbances. A good combination of the parameters applied to TN9 and TN20 can be useful in obtaining stable combustion. In addition, the ash agglomerations were influenced by the duration of the combustion and the temperature of the fuel bed. The largest size of the ash agglomeration was referred to as test number-TN26 (P: 16 kW, EA: 110%, SR: 30/70, and GA: 115 mm × 75 mm), which is 59 mm, and the duration time is 14,400 s (≈4 h).
id RCAP_b80f2671dfdb7345d6430d945e4bcc71
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/87333
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Combustion instability and ash agglomeration in wood pellets boilerCombustion instabilityAsh agglomerationWood pelletBoilerThe combustion instability and ash agglomeration in a wood pellet boiler were investigated in this study. The tests were conducted using the Taguchi method of orthogonal array L<sub>27</sub>(13<sup>3</sup>). Several parameters are applied, including grate area (GA), primary to secondary air split ratio (SR), excess air (EA), and fuel power (P). Pine wood pellets were used, and the boiler’s nominal load was 20 kW. The results show that instability during combustion occurs since the fuel bed rises as the accumulation of the unburned wood pellets on the grate causes a slow combustion rate and pressure drop, which creates noise and disturbances. A good combination of the parameters applied to TN9 and TN20 can be useful in obtaining stable combustion. In addition, the ash agglomerations were influenced by the duration of the combustion and the temperature of the fuel bed. The largest size of the ash agglomeration was referred to as test number-TN26 (P: 16 kW, EA: 110%, SR: 30/70, and GA: 115 mm × 75 mm), which is 59 mm, and the duration time is 14,400 s (≈4 h).This work has been supported by FCT—Fundação para a Ciência e Tecnologia within the R&D Units, MEtRICs Project Scope: UIDB/04077/2020; Lelis Fraga was supported through a PhD Grant by Fundo de Desenvolvimento Capital Humano of the Government of Timor Leste.Multidisciplinary Digital Publishing Institute (MDPI)Universidade do MinhoFraga, LelisFerreira, Manuel Eduardo CardosoRibeiro, Pedro Emanuel AbreuCastro, Carlos Eduardo RodriguesMartins, JorgeTeixeira, J. Carlos2023-09-112023-09-11T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/1822/87333engFraga, L.; Ferreira, E.; Ribeiro, P.; Castro, C.; Martins, J.; Teixeira, J.C. Combustion Instability and Ash Agglomeration in Wood Pellets Boiler. Energies 2023, 16, 6539. https://doi.org/10.3390/en161865391996-107310.3390/en161865396539https://www.mdpi.com/1996-1073/16/18/6539info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-12-02T01:21:35Zoai:repositorium.sdum.uminho.pt:1822/87333Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:40:31.466604Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Combustion instability and ash agglomeration in wood pellets boiler
title Combustion instability and ash agglomeration in wood pellets boiler
spellingShingle Combustion instability and ash agglomeration in wood pellets boiler
Fraga, Lelis
Combustion instability
Ash agglomeration
Wood pellet
Boiler
title_short Combustion instability and ash agglomeration in wood pellets boiler
title_full Combustion instability and ash agglomeration in wood pellets boiler
title_fullStr Combustion instability and ash agglomeration in wood pellets boiler
title_full_unstemmed Combustion instability and ash agglomeration in wood pellets boiler
title_sort Combustion instability and ash agglomeration in wood pellets boiler
author Fraga, Lelis
author_facet Fraga, Lelis
Ferreira, Manuel Eduardo Cardoso
Ribeiro, Pedro Emanuel Abreu
Castro, Carlos Eduardo Rodrigues
Martins, Jorge
Teixeira, J. Carlos
author_role author
author2 Ferreira, Manuel Eduardo Cardoso
Ribeiro, Pedro Emanuel Abreu
Castro, Carlos Eduardo Rodrigues
Martins, Jorge
Teixeira, J. Carlos
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Fraga, Lelis
Ferreira, Manuel Eduardo Cardoso
Ribeiro, Pedro Emanuel Abreu
Castro, Carlos Eduardo Rodrigues
Martins, Jorge
Teixeira, J. Carlos
dc.subject.por.fl_str_mv Combustion instability
Ash agglomeration
Wood pellet
Boiler
topic Combustion instability
Ash agglomeration
Wood pellet
Boiler
description The combustion instability and ash agglomeration in a wood pellet boiler were investigated in this study. The tests were conducted using the Taguchi method of orthogonal array L<sub>27</sub>(13<sup>3</sup>). Several parameters are applied, including grate area (GA), primary to secondary air split ratio (SR), excess air (EA), and fuel power (P). Pine wood pellets were used, and the boiler’s nominal load was 20 kW. The results show that instability during combustion occurs since the fuel bed rises as the accumulation of the unburned wood pellets on the grate causes a slow combustion rate and pressure drop, which creates noise and disturbances. A good combination of the parameters applied to TN9 and TN20 can be useful in obtaining stable combustion. In addition, the ash agglomerations were influenced by the duration of the combustion and the temperature of the fuel bed. The largest size of the ash agglomeration was referred to as test number-TN26 (P: 16 kW, EA: 110%, SR: 30/70, and GA: 115 mm × 75 mm), which is 59 mm, and the duration time is 14,400 s (≈4 h).
publishDate 2023
dc.date.none.fl_str_mv 2023-09-11
2023-09-11T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/87333
url https://hdl.handle.net/1822/87333
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Fraga, L.; Ferreira, E.; Ribeiro, P.; Castro, C.; Martins, J.; Teixeira, J.C. Combustion Instability and Ash Agglomeration in Wood Pellets Boiler. Energies 2023, 16, 6539. https://doi.org/10.3390/en16186539
1996-1073
10.3390/en16186539
6539
https://www.mdpi.com/1996-1073/16/18/6539
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Multidisciplinary Digital Publishing Institute (MDPI)
publisher.none.fl_str_mv Multidisciplinary Digital Publishing Institute (MDPI)
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799136310743531520