Optical and visual quality of two scleral lenses

Detalhes bibliográficos
Autor(a) principal: Marques, Ana Luísa Moreira
Data de Publicação: 2020
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: https://hdl.handle.net/1822/80577
Resumo: Dissertação de mestrado em Optometria Avançada
id RCAP_b8d4329085cc39cc781815cf3b94e157
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/80577
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Optical and visual quality of two scleral lensesAltura sagitalCórnea irregularLente escleralQualidade óticaIrregular corneaOptical qualitySagittal heightScleral lensCiências Naturais::Ciências FísicasDissertação de mestrado em Optometria AvançadaAtualmente, as lentes esclerais são bastante adaptadas em pacientes que sofrem de doenças da superfície ocular. Estes dispositivos são também indicados em várias doenças ou irregularidades corneais devido à sua capacidade de criarem um reservatório de líquido, que irá compensar a maior parte das irregularidades da superfície. As inovações tecnológicas têm providenciado uma larga diversidade de desenhos e materiais de lentes esclerais. Contudo, ainda existem poucos estudos que reportem o uso prolongado destas lentes e como a qualidade ótica pode ser influenciada por este uso prolongado. Assim, com este trabalho pretende-se avaliar a resposta da superfície ocular quando uma lente nova e diferente é adaptada bem como entender se é possível readaptar usuários habituais de lentes esclerais a partir dos dados obtidos com a topografia corneal. Neste estudo, os resultados com uma lente escleral (Senso Mini Sclera, 16.4 mm), usada durante mais de 12 meses, foram comparados com os resultados de uma nova lente de outra marca de lentes esclerais (ICD, 16.5 mm), readaptada e usada durante 1 mês. Dos principais resultados obtidos, observou-se que existiam algumas diferenças na qualidade ótica entre a Senso Mini Sclera e a ICD, no entanto os resultados subjetivos não mostraram diferenças significativas relativamente à visão e ao conforto entre ambas as lentes. Os dados da resposta da superfície ocular mostraram valores significativamente mais baixos de hiperemia bulbar, hiperemia limbar, tingido limbar e tingido corneal após 1 mês de uso da lente ICD, quando comparados aos valores obtidos imediatamente após retirar a Senso Mini Sclera. Os resultados mostraram que os dados de elevação na corda de 6mm, obtidos com um topografo corneal comum, estavam correlacionados com as alturas sagitais das lentes ICD diagnóstico e finais. Os resultados com a lente ICD em duas visitas diferentes (após 3h, na visita de entrega, e após 1 mês) não revelaram diferenças significativas, mostrando que a avaliação a curto prazo é um bom preditor dos resultados a médio prazo. Em conclusão, com este estudo foi verificado que pode ser possível readaptar usuários habituais de lentes esclerais com outra lente escleral, apesar de possuírem características diferentes, mantendo a qualidade ótica e o conforto. As pequenas diferenças entre as duas lentes podem estar relacionadas com o tempo de uso da Senso Mini Sclera, que pode ter um pequeno impacto na degradação da qualidade ótica. Os resultados deste estudo sugerem que as maiores respostas da superfície ocular com a Senso Mini Sclera podem ser devido à degradação que a lente sofre com o tempo ou devido às diferenças nos materiais das lentes.Nowadays, scleral lenses are largely fitted to patients who suffer from ocular surface diseases. These devices are also indicated in several corneal disorders or irregularities due to the capability of create a fluid reservoir, which will compensate most of the surface irregularities. Technological innovations have provided a large diversity of scleral lenses designs and materials. However, there are still very few studies reporting the long-term use of these lenses and how optical quality could be influenced by this long-term use. This work intents to evaluate the ocular surface response when a new different lens is fitted and to understand if it is possible to refit habitual scleral lenses users, from the data obtained with corneal topography. In this study, the results with a scleral lens (Senso Mini Sclera, 16.4 mm), used for more than 12 months, were compared to the results of a new lens from another scleral lens (ICD, 16.5 mm), refitted and used during 1 month. From the main outcomes obtained, it was observed that there were a few differences on optical quality between Senso Mini Sclera and ICD, although the subjective results showed no significant differences relatively to vision and comfort between both lenses. The data from ocular surface response showed lower statistically significant values of bulbar hyperemia, limbal hyperemia, limbal staining and corneal staining after 1 month of ICD lens wear when compared to the values immediately after Senso Mini Sclera removal. The results showed that the 6mm chord elevation data, obtained with a common corneal topographer, was correlated with diagnostic and final sagittal depth of ICD lenses. The results with ICD in two different visits (after 3h on the dispensing visit and after 1 month) did not reveal significative differences, showing that the short-term evaluation is a good predictor of the medium-term behavior. In conclusion, with this study we verified that might be possible to refit habitual scleral lens users with another scleral lens, despite the different characteristics, maintaining the optical quality and comfort. The small differences between the two lenses may be correlated with Senso Mini Sclera lifetime, which could have a small impact on optical quality degradation. The results of this study suggest that the highest ocular surface response values with Senso Mini Sclera might be due to the degradation that lens suffered over time or due to the differences on lenses material.González-Méijome, José ManuelMacedo-de-Araújo, Rute J.Universidade do MinhoMarques, Ana Luísa Moreira2020-02-062020-02-06T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttps://hdl.handle.net/1822/80577eng202473694info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-12-16T01:19:07Zoai:repositorium.sdum.uminho.pt:1822/80577Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:30:42.966755Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Optical and visual quality of two scleral lenses
title Optical and visual quality of two scleral lenses
spellingShingle Optical and visual quality of two scleral lenses
Marques, Ana Luísa Moreira
Altura sagital
Córnea irregular
Lente escleral
Qualidade ótica
Irregular cornea
Optical quality
Sagittal height
Scleral lens
Ciências Naturais::Ciências Físicas
title_short Optical and visual quality of two scleral lenses
title_full Optical and visual quality of two scleral lenses
title_fullStr Optical and visual quality of two scleral lenses
title_full_unstemmed Optical and visual quality of two scleral lenses
title_sort Optical and visual quality of two scleral lenses
author Marques, Ana Luísa Moreira
author_facet Marques, Ana Luísa Moreira
author_role author
dc.contributor.none.fl_str_mv González-Méijome, José Manuel
Macedo-de-Araújo, Rute J.
Universidade do Minho
dc.contributor.author.fl_str_mv Marques, Ana Luísa Moreira
dc.subject.por.fl_str_mv Altura sagital
Córnea irregular
Lente escleral
Qualidade ótica
Irregular cornea
Optical quality
Sagittal height
Scleral lens
Ciências Naturais::Ciências Físicas
topic Altura sagital
Córnea irregular
Lente escleral
Qualidade ótica
Irregular cornea
Optical quality
Sagittal height
Scleral lens
Ciências Naturais::Ciências Físicas
description Dissertação de mestrado em Optometria Avançada
publishDate 2020
dc.date.none.fl_str_mv 2020-02-06
2020-02-06T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/80577
url https://hdl.handle.net/1822/80577
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 202473694
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132812139298816