Predictability of different calculating strategies for corneal tissue ablation by excimer laser
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Tipo de documento: | Dissertação |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.21/16563 |
Resumo: | Thesis to obtain the Master's Degree in Biomedical Engineering |
id |
RCAP_b93b2c4984a777e90938c765f8c5e959 |
---|---|
oai_identifier_str |
oai:repositorio.ipl.pt:10400.21/16563 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Predictability of different calculating strategies for corneal tissue ablation by excimer laserCirurgia refractivaLasikLaser excimerAblação de tecido corneanoFórmula de MunnerlynRefractive surgeryLASIKExcimer laserCorneal tissue ablationMunnerlyn's formulaThesis to obtain the Master's Degree in Biomedical EngineeringActualmente existem vários métodos para melhorar a qualidade da visão, incluindo óculos, lentes de contacto ou recorrendo a cirurgia refractiva. A cirurgia refractiva a laser é um procedimento que recorre a laser excimer de modo a remover tecido corneano e corrigir erros refractivos, através da alteração do formato da córnea. Laser excimer TENEO 317 (Bausch & Lomb Technolas, Munich, Germany) utiliza tratamento Proscan ou Zyoptix, personalizado para cada paciente. De modo a garantir a segurança do paciente e a eficácia dos resultados, o tratamento efectuado pelo laser excimer tem tradicionalmente por base uma fórmula matemática, denominada fórmula exacta de Munnerlyn. Esta fórmula prevê a quantidade de tecido corneano removido (ablação) durante o tratamento, sendo que uma fórmula de Munnerlyn simplificada e aproximada permite obter este valor de uma forma mais imediata. a principal questão apresentada nesta tese tratou-se de aferir se a medição de ablação prevista pelo laser corresponde efectivamente à ablação real ocorrida na cirurgia. Adicionalmente, foi investigado se ambas as fórmulas aproximada e exacta de Munnerlyn ainda são fiáveis, para ambos os tratamentos. Para estudar esta questão, foi efectuada uma análise estatística (n = 86 olhos) de modo a avaliar qual dos sequintes seria mais preciso: simulador pertencente à plataforma do laser, a fórmula aproximafa de Munnerlyn ou a fórmula exacta de Munnerlyn. A espessura da córnea (paquimetria) dos 86 olhos foi medida a três aparelhos (tomografia de coerência óptica de segmento anterior, topografia por varrimento em fenda e tomografia de Scheimpflug) tanto no pré como no pós-operatório. Posteriormente foi realizada uma análise estatística. Os resultados para os tratamentos Proscan e Zyoptix demonstraram que a simulação do laser é precisa, quando comparado com as medições reais de ablação. Relativamente ás fórmulas de Munnerlyn, concluiu-se que os cirurgiões podem confiar nestas fórmulas para o tratamento Proscan. No tratamento Zyoptix, as fórmulas de Munnerlyn subestimam a profundidade de ablação. Esta tese também estudou: a precisão da espessura do flap (corte fino na córnea para aceder ao estroma, onde o laser é aplicado) que demostrou algumas variações que podem ser consideradas clinicamente insignificantes; e a comparabilidade entre três aparelhos diferentes de paquimetria, onde o Orbscan (Bausch & Lomb, Rochester, New York, USA) provou ser o mais variável nos seus resultados e o Pentacam (Oculus, Wetzlar, Germany) demostrou ser o mais confiável, quando comparados com o Visante (Carl Zeiss Meditec, Jena, Germany).Currently there are many ways to improve the quality of vision, including glasses, contact lenses or refractive surgery. Laser refractive surgery is a procedure that uses an excimer laser to ablate corneal tissue and correct refractive errors by reshaping the cornea. Excimer laser TENEO 317 (Bausch & Lomb Technolas, Munich, Germany) uses either a Proscan or a Zyoptix treatment, which is customized to each patient. To guarantee patient safety and effective results, the treatment performed by the excimer laser is traditionally based on a methematical formula, Munnerlyn's exact formula. This formula predicts the amount of corneal tissue that will be ablated during the procedure, and a simplified but approximated Munnerlyn´s formula may be used to easily obtain this value. The central question of the current thesis was to measure if the corneal ablation thickness predicted by the laser corresponds to the real corneal ablation during the surgery. Additionally, we will investigate whether Munnerlyn´s approximated and exact formulas are still reliable, for both types of treatment. To study this question, a statistical analysis was performed (n = 86 eyes) to test which of the following is the most accurate: the laser platform proprietary simulation, Munnerlyn´s approximated formula or Munnerlyn´s exact formula. The cornea thickness (pachymetry) of the 86 eyes was meaured using three devices (Anterior segment optical coherence tomography, slit-scan topography and Scheimpflug tomography) both pre-and postoperatively. An adequate statistical analysis was subsequently performed. The results for Proscan and Zyoptix treatmen showed that the excimer simulation is accurate, when compared to the real measurements. Regarding Munnerlun´s formulas, we concluded that surgeons could rely on them in Proscan treattments. In the case of Zyoptix treatments, Munnerlyn's formula underestimated the ablation depth. This thesis also studied: the accuracy of flap thickness (a thin cut in the cornea to access the stroma, where the laser acts) showed some variances that could be considered to be clinical insignificant; and the comparability among three different pachymetry devices, where Orbscan (Bausch & Lomb, Rochester, New York, USA) has proven to be the most uncertain and Pentacam (Oculus, Wetzlar, Germany) the most reliable, when comparing to Visante (Carl Zeiss Meditec, Jena, Germany).Ferreira, Tiago Luís do Carmo BravoSilva, Pedro Manuel Alves Patrício daRCIPLGaspar, Sylvia Annabelle Grilo2023-10-13T14:19:08Z20222022-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10400.21/16563TID:203360419engGASPAR, Sylvia Annabelle Grilo - Predictability of different calculating strategies for corneal tissue ablation by excimer laser. Lisboa: Instituto Superior de Engenharia de Lisboa, 2022. Dissertação de Mestrado.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-10-18T02:15:32Zoai:repositorio.ipl.pt:10400.21/16563Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:35:55.540481Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Predictability of different calculating strategies for corneal tissue ablation by excimer laser |
title |
Predictability of different calculating strategies for corneal tissue ablation by excimer laser |
spellingShingle |
Predictability of different calculating strategies for corneal tissue ablation by excimer laser Gaspar, Sylvia Annabelle Grilo Cirurgia refractiva Lasik Laser excimer Ablação de tecido corneano Fórmula de Munnerlyn Refractive surgery LASIK Excimer laser Corneal tissue ablation Munnerlyn's formula |
title_short |
Predictability of different calculating strategies for corneal tissue ablation by excimer laser |
title_full |
Predictability of different calculating strategies for corneal tissue ablation by excimer laser |
title_fullStr |
Predictability of different calculating strategies for corneal tissue ablation by excimer laser |
title_full_unstemmed |
Predictability of different calculating strategies for corneal tissue ablation by excimer laser |
title_sort |
Predictability of different calculating strategies for corneal tissue ablation by excimer laser |
author |
Gaspar, Sylvia Annabelle Grilo |
author_facet |
Gaspar, Sylvia Annabelle Grilo |
author_role |
author |
dc.contributor.none.fl_str_mv |
Ferreira, Tiago Luís do Carmo Bravo Silva, Pedro Manuel Alves Patrício da RCIPL |
dc.contributor.author.fl_str_mv |
Gaspar, Sylvia Annabelle Grilo |
dc.subject.por.fl_str_mv |
Cirurgia refractiva Lasik Laser excimer Ablação de tecido corneano Fórmula de Munnerlyn Refractive surgery LASIK Excimer laser Corneal tissue ablation Munnerlyn's formula |
topic |
Cirurgia refractiva Lasik Laser excimer Ablação de tecido corneano Fórmula de Munnerlyn Refractive surgery LASIK Excimer laser Corneal tissue ablation Munnerlyn's formula |
description |
Thesis to obtain the Master's Degree in Biomedical Engineering |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022 2022-01-01T00:00:00Z 2023-10-13T14:19:08Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.21/16563 TID:203360419 |
url |
http://hdl.handle.net/10400.21/16563 |
identifier_str_mv |
TID:203360419 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
GASPAR, Sylvia Annabelle Grilo - Predictability of different calculating strategies for corneal tissue ablation by excimer laser. Lisboa: Instituto Superior de Engenharia de Lisboa, 2022. Dissertação de Mestrado. |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133622580543488 |