Otimização do processo de monitorização de elétrodos seletivos de ião

Detalhes bibliográficos
Autor(a) principal: Costa, Daniel João Cerqueira da
Data de Publicação: 2019
Tipo de documento: Dissertação
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.22/14899
Resumo: During the Ion-selective electrode research process, there are a lot of manual calibrations needed in order to achieve better and more effective results. The main goal of most of the researchers in these areas is about the material behaviours and reactions, but there is no way to test them without building the electrode and testing against various possibilities and mediums. Due to this, the research process usually cannot be a continuous process, since there are some interruptions for the manual process to validate all the previous developments. The human based calibration process is fundamental for many conclusions, but, most of the calibrations logic can be implemented in a machine that automates the process, collects the data, and generates the necessary output. The main goal of this MSc thesis is to optimize the calibration process building a calibration box that is fully configurable, and can be replicated, replacing the researcher manual steps during the membrane testing. Herein, it is possible to find the selected hardware and software architecture used, and also the business logic implemented to achieve the automation of these process. The architecture and implementation were designed to be able to work with a digital potentiometer (Crison GLP 21 pH Potentiometer) and a digital precise fluid pump (Legato 100). The solution contains four main components: • External Devices (Digital pH Meter, Digital Peristaltic Pump); • Server side web services and web application; • Cloud Based Deployment (Serverless, Storage, Database); • Hardware automation box; The implementation of this thesis uses the following technologies: • Code: Java, Spring Boot, Spring Data; • Data: JSON, Excel XML OpenFormat, PostgresSQL; • Hardware: RaspberryPi, Relay Boards, LCD Display, Button, LED; • I/O: Ethernet, USB to RS232, RCA, BNC; • Cloud: Heroku Serverless; Heroku PostgresSQL; Amazon S3 Storage; All the membranes used were made by BioMark researchers.
id RCAP_ba049b7ea25eeefdbc7e5dab391e5b29
oai_identifier_str oai:recipp.ipp.pt:10400.22/14899
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Otimização do processo de monitorização de elétrodos seletivos de iãoAutomationJavaResearchSpringDataRaspberry PiGPIOCloudServerlessPostgreSQLS3BioMarkDuring the Ion-selective electrode research process, there are a lot of manual calibrations needed in order to achieve better and more effective results. The main goal of most of the researchers in these areas is about the material behaviours and reactions, but there is no way to test them without building the electrode and testing against various possibilities and mediums. Due to this, the research process usually cannot be a continuous process, since there are some interruptions for the manual process to validate all the previous developments. The human based calibration process is fundamental for many conclusions, but, most of the calibrations logic can be implemented in a machine that automates the process, collects the data, and generates the necessary output. The main goal of this MSc thesis is to optimize the calibration process building a calibration box that is fully configurable, and can be replicated, replacing the researcher manual steps during the membrane testing. Herein, it is possible to find the selected hardware and software architecture used, and also the business logic implemented to achieve the automation of these process. The architecture and implementation were designed to be able to work with a digital potentiometer (Crison GLP 21 pH Potentiometer) and a digital precise fluid pump (Legato 100). The solution contains four main components: • External Devices (Digital pH Meter, Digital Peristaltic Pump); • Server side web services and web application; • Cloud Based Deployment (Serverless, Storage, Database); • Hardware automation box; The implementation of this thesis uses the following technologies: • Code: Java, Spring Boot, Spring Data; • Data: JSON, Excel XML OpenFormat, PostgresSQL; • Hardware: RaspberryPi, Relay Boards, LCD Display, Button, LED; • I/O: Ethernet, USB to RS232, RCA, BNC; • Cloud: Heroku Serverless; Heroku PostgresSQL; Amazon S3 Storage; All the membranes used were made by BioMark researchers.Durante o processo de pesquisa de eletrodos seletivos de íons, há muitas calibrações manuais necessárias para obter resultados melhores e mais eficazes. O objetivo principal da maioria dos investigadores nestas áreas ´e relativa aos comportamentos e reações dos materiais, mas não existe uma maneira de testá-los sem construir o elétrodo e testar contra várias possibilidades e meios. Por este motivo, o processo de pesquisa geralmente não pode ser um processo contínuo, uma vez que existem algumas interrupções no mesmo para manualmente validar todos os desenvolvimentos anteriores. O processo de calibração baseado em trabalho manual ´e fundamental para uma grande parte das conclusões, mas a maior parte da lógica de calibração pode ser implementada e executada por uma máquina que automatiza o processo, recolhe os dados e gera a saída necessária para posterior analise do investigador. O objetivo principal desta tese de mestrado ´e otimizar o processo de calibração construindo uma caixa de calibração totalmente configurável e que pode ser replicada, substituindo as etapas manuais do investigador durante o teste das membranas. Neste relatório, é possível encontrar a arquitetura de hardware e software selecionada e utilizada bem como a lógica implementada para alcançar a automação desses processos. A arquitetura e a implementação foram projetadas para poder trabalhar com um potenciómetro digital (Potenciómetro de pH Crison GLP 21) e uma bomba de fluido (Legato 100). A solução contém quatro componentes principais: • Dispositivos Externos (Medidor de pH Digital, Bomba Peristáltica Digital); • Server side web services e aplicação Web; • Cloud Based Deployment (Serverless, Storage, Database); • Caixa de automação (Hardware); A implementação desta tese utiliza as seguintes tecnologias: • Código: Java, Spring Boot, Spring Data; • Dados: JSON, Excel XML OpenFormat, PostgresSQL; • Hardware: RaspberryPi, Relay Boards, LCD Display, Button, LED; • I/O: Ethernet, USB to RS232, RCA, BNC ; • Cloud: Heroku Serverless; Heroku PostgresSQL; Amazon S3 Storage; Todas as membranas utilizadas foram desenvolvidas por investigadores da BioMark.Sales, Maria Goreti FerreiraRepositório Científico do Instituto Politécnico do PortoCosta, Daniel João Cerqueira da2019-11-21T15:00:11Z20192019-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/10400.22/14899TID:202295710enginfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-13T12:58:32Zoai:recipp.ipp.pt:10400.22/14899Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:34:42.059222Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Otimização do processo de monitorização de elétrodos seletivos de ião
title Otimização do processo de monitorização de elétrodos seletivos de ião
spellingShingle Otimização do processo de monitorização de elétrodos seletivos de ião
Costa, Daniel João Cerqueira da
Automation
Java
Research
Spring
Data
Raspberry Pi
GPIO
Cloud
Serverless
PostgreSQL
S3
BioMark
title_short Otimização do processo de monitorização de elétrodos seletivos de ião
title_full Otimização do processo de monitorização de elétrodos seletivos de ião
title_fullStr Otimização do processo de monitorização de elétrodos seletivos de ião
title_full_unstemmed Otimização do processo de monitorização de elétrodos seletivos de ião
title_sort Otimização do processo de monitorização de elétrodos seletivos de ião
author Costa, Daniel João Cerqueira da
author_facet Costa, Daniel João Cerqueira da
author_role author
dc.contributor.none.fl_str_mv Sales, Maria Goreti Ferreira
Repositório Científico do Instituto Politécnico do Porto
dc.contributor.author.fl_str_mv Costa, Daniel João Cerqueira da
dc.subject.por.fl_str_mv Automation
Java
Research
Spring
Data
Raspberry Pi
GPIO
Cloud
Serverless
PostgreSQL
S3
BioMark
topic Automation
Java
Research
Spring
Data
Raspberry Pi
GPIO
Cloud
Serverless
PostgreSQL
S3
BioMark
description During the Ion-selective electrode research process, there are a lot of manual calibrations needed in order to achieve better and more effective results. The main goal of most of the researchers in these areas is about the material behaviours and reactions, but there is no way to test them without building the electrode and testing against various possibilities and mediums. Due to this, the research process usually cannot be a continuous process, since there are some interruptions for the manual process to validate all the previous developments. The human based calibration process is fundamental for many conclusions, but, most of the calibrations logic can be implemented in a machine that automates the process, collects the data, and generates the necessary output. The main goal of this MSc thesis is to optimize the calibration process building a calibration box that is fully configurable, and can be replicated, replacing the researcher manual steps during the membrane testing. Herein, it is possible to find the selected hardware and software architecture used, and also the business logic implemented to achieve the automation of these process. The architecture and implementation were designed to be able to work with a digital potentiometer (Crison GLP 21 pH Potentiometer) and a digital precise fluid pump (Legato 100). The solution contains four main components: • External Devices (Digital pH Meter, Digital Peristaltic Pump); • Server side web services and web application; • Cloud Based Deployment (Serverless, Storage, Database); • Hardware automation box; The implementation of this thesis uses the following technologies: • Code: Java, Spring Boot, Spring Data; • Data: JSON, Excel XML OpenFormat, PostgresSQL; • Hardware: RaspberryPi, Relay Boards, LCD Display, Button, LED; • I/O: Ethernet, USB to RS232, RCA, BNC; • Cloud: Heroku Serverless; Heroku PostgresSQL; Amazon S3 Storage; All the membranes used were made by BioMark researchers.
publishDate 2019
dc.date.none.fl_str_mv 2019-11-21T15:00:11Z
2019
2019-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.22/14899
TID:202295710
url http://hdl.handle.net/10400.22/14899
identifier_str_mv TID:202295710
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131438830845952