Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches

Detalhes bibliográficos
Autor(a) principal: Goncalves, J.C.
Data de Publicação: 2012
Outros Autores: Costa, J.J., Figueiredo, A.R., Lopes, A.M.G.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.19/6124
Resumo: An experimental study was conducted in a laboratory scale model in order to characterize the airflow generated by an air curtain device (ACD) on the aerodynamic sealing of refrigerated spaces. The laboratory scale model consists of two similar adjacent rooms connected by a door over which the ACD device was installed. The tracer gas technique was used to calculate the sealing effect achieved with the air curtain at different jet velocities. A three-dimensional numerical model was also developed to simulate the heat and mass transfer phenomena, as well as the aerodynamic sealing performance of an ACD. The numerical study was carried out using a commercial CFD code (ANSYS-CFX®) and the turbulence effects were approached by two different turbulence models (k–ε and k–ω SST). The experimental and numerical results show a good agreement for validation purposes. No significant differences were found in the results obtained with the two turbulence models, although the k–ω SST model seems to be more appropriate for the simulations. The existence of an optimum discharge air jet velocity was confirmed. The results also indicate that the air curtain is more efficient in reducing the mass transfer than the energy flow rate across the doorway.
id RCAP_bd82dbd9c7f235afc33e0281b70f29ce
oai_identifier_str oai:repositorio.ipv.pt:10400.19/6124
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Study of the aerodynamic sealing of a cold store – Experimental and numerical approachesAir curtainRefrigerated roomSealing efficiencyHeat transferCFDEnergy savingAn experimental study was conducted in a laboratory scale model in order to characterize the airflow generated by an air curtain device (ACD) on the aerodynamic sealing of refrigerated spaces. The laboratory scale model consists of two similar adjacent rooms connected by a door over which the ACD device was installed. The tracer gas technique was used to calculate the sealing effect achieved with the air curtain at different jet velocities. A three-dimensional numerical model was also developed to simulate the heat and mass transfer phenomena, as well as the aerodynamic sealing performance of an ACD. The numerical study was carried out using a commercial CFD code (ANSYS-CFX®) and the turbulence effects were approached by two different turbulence models (k–ε and k–ω SST). The experimental and numerical results show a good agreement for validation purposes. No significant differences were found in the results obtained with the two turbulence models, although the k–ω SST model seems to be more appropriate for the simulations. The existence of an optimum discharge air jet velocity was confirmed. The results also indicate that the air curtain is more efficient in reducing the mass transfer than the energy flow rate across the doorway.Energy and BuildingsRepositório Científico do Instituto Politécnico de ViseuGoncalves, J.C.Costa, J.J.Figueiredo, A.R.Lopes, A.M.G.2020-01-23T11:48:11Z20122012-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.19/6124engGonçalves, J.C., Costa, J.J., Figueiredo, A.R., & Lopes, A.M.G. (2012). Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches. Energy and Buildings, 55, 779-789. doi:10.1016/j.enbuild.2012.10.02110.1016/j.enbuild.2012.10.021metadata only accessinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-01-16T15:27:03Zoai:repositorio.ipv.pt:10400.19/6124Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T16:42:50.254750Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches
title Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches
spellingShingle Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches
Goncalves, J.C.
Air curtain
Refrigerated room
Sealing efficiency
Heat transfer
CFD
Energy saving
title_short Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches
title_full Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches
title_fullStr Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches
title_full_unstemmed Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches
title_sort Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches
author Goncalves, J.C.
author_facet Goncalves, J.C.
Costa, J.J.
Figueiredo, A.R.
Lopes, A.M.G.
author_role author
author2 Costa, J.J.
Figueiredo, A.R.
Lopes, A.M.G.
author2_role author
author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Politécnico de Viseu
dc.contributor.author.fl_str_mv Goncalves, J.C.
Costa, J.J.
Figueiredo, A.R.
Lopes, A.M.G.
dc.subject.por.fl_str_mv Air curtain
Refrigerated room
Sealing efficiency
Heat transfer
CFD
Energy saving
topic Air curtain
Refrigerated room
Sealing efficiency
Heat transfer
CFD
Energy saving
description An experimental study was conducted in a laboratory scale model in order to characterize the airflow generated by an air curtain device (ACD) on the aerodynamic sealing of refrigerated spaces. The laboratory scale model consists of two similar adjacent rooms connected by a door over which the ACD device was installed. The tracer gas technique was used to calculate the sealing effect achieved with the air curtain at different jet velocities. A three-dimensional numerical model was also developed to simulate the heat and mass transfer phenomena, as well as the aerodynamic sealing performance of an ACD. The numerical study was carried out using a commercial CFD code (ANSYS-CFX®) and the turbulence effects were approached by two different turbulence models (k–ε and k–ω SST). The experimental and numerical results show a good agreement for validation purposes. No significant differences were found in the results obtained with the two turbulence models, although the k–ω SST model seems to be more appropriate for the simulations. The existence of an optimum discharge air jet velocity was confirmed. The results also indicate that the air curtain is more efficient in reducing the mass transfer than the energy flow rate across the doorway.
publishDate 2012
dc.date.none.fl_str_mv 2012
2012-01-01T00:00:00Z
2020-01-23T11:48:11Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.19/6124
url http://hdl.handle.net/10400.19/6124
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Gonçalves, J.C., Costa, J.J., Figueiredo, A.R., & Lopes, A.M.G. (2012). Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches. Energy and Buildings, 55, 779-789. doi:10.1016/j.enbuild.2012.10.021
10.1016/j.enbuild.2012.10.021
dc.rights.driver.fl_str_mv metadata only access
info:eu-repo/semantics/openAccess
rights_invalid_str_mv metadata only access
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Energy and Buildings
publisher.none.fl_str_mv Energy and Buildings
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130896517824512